Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
Prewired complete unit consisting of a base part and plug-in protection modules
Energy coordination with other arresters of the Red/Line product family
High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps
High reliability due to "Thermo Dynamic Control" SPD monitoring device
Easy replacement of protection modules without tools due to module locking system with module release button
Vibration and shock-tested according to EN 60068-2
At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates.
Featuring the functional Red/Line family design, the modular DEHNguard M surge arresters set new standards in terms of safety and ease of use. The proven protective circuit with heavy-duty zinc oxide varistors in combination with the dual "Thermo Dynamic Control" monitoring device are characteristic of the DEHNguard technology.
A variety of features show that both reliable surge protection and equipment safety are key elements of the modular DEHNguard surge arresters. The application-based product designation, which makes it considerably easier to choose the correct device for the relevant application and the unique module locking system both reflect the most stringent safety requirements.
The module locking system firmly fixes the protection modules to the base part. Neither vibration during transport nor the enormous forces of discharge can loosen the protection modules.
Nevertheless, they can be easily replaced without tools by simply pressing the easy-to use module release button of the protection modules. Each protective circuit of the multipole surge arresters and each protection module are mechanically coded to guard against installing an incorrect module.
The dual "Thermo Dynamic Control" monitoring device was not only developed on the basis of national and international product standards, but also reflects decades of experience in the world market of surge protective devices and considers many practical applications where arresters might be damaged. As with all DEHN surge arresters with "Thermo Dynamic Control", the surface temperature of the heavy-duty varistor and the intensity of the discharge current are used for evaluation. The visual indicator with green and red indicator flags shows the availability of every protective circuit. Apart from this standard visual indication, DEHNguard M ... FM devices feature a three-pole remote signalling terminal.
As the remote signalling contact is designed as a floating changeover contact, the remote signal can, depending on the circuit concept, be used as a make or break contact. The surge arresters of the modular multipole DEHNguard M family feature multifunctional terminals on a standardised spacing of 1 module for the connection of conductors and busbars, allowing easy wiring with other DIN rail mounted devices. The STAK 25 pin-shaped terminal, which is compatible with all DEHNguard modules, allows optimal "V-connection" according to IEC 60364-5-53.
The DEHNguard M H TT … type already meets the requirements of the new VDE 0100-534 standard (Table: Discharge values In in a 3+1 configuration for three-phase systems with increased safety requirements). This standard requires at least 40 kA for the N-PE path. Since it was technically possible to implement a discharge capacity of 80 kA here, even an arithmetically correct design (4 x 20 kA = 80 kA) in combination with standard varistor modules with In = 20 kA was implemented.
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Energy coordination with terminal equipment (≤ 10 m) | type 2 + type 3 |
Nominal voltage (a.c.) (UN ) | 230 / 400 V (50 / 60 Hz) |
Max. continuous operating voltage (a.c.) (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 20 kA |
Max. discharge current (8/20 µs) (Imax ) | 40 kA |
Voltage protection level [L-PE]/[N-PE] (UP ) | ≤ 1.5 / ≤ 1.5 kV |
Voltage protection level [L-PE] / [N-PE] at 5 kA (UP ) | ≤ 1 / ≤ 1 kV |
Response time (tA ) | ≤ 25 ns |
Max. mains-side overcurrent protection | 125 A gG |
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR ) | 50 kArms |
Temporary overvoltage (TOV) (UT) – Characteristic | 335 V / 5 sec. – withstand |
Temporary overvoltage (TOV) (UT) – Characteristic | 440 V / 120 min. – safe failure |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
For mounting on | 35 mm DIN rails acc. to EN 60715 |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 20 |
Capacity | 4 module(s), DIN 43880 |
Approvals | KEMA, VDE, UL |
Type of remote signalling contact | changeover contact |
Switching capacity (a.c.) | 250 V / 0.5 A |
Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
By submitting your details you consent to their use in accordance with our Privacy Notice