Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
Analox Ax60+ Kiosk
A wall mount, single point CO2 monitor, designed for kiosks.
Carbon dioxide (CO2) is stored and used in several industries including beverage and hospitality, laboratory and agriculture. CO2 is a toxic gas and a relatively small volume can cause serious health risks if it builds up in the confines of a small space.
The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of CO2. Extra alarms can be added as needed and the unit does not need periodic calibration.
The sensor should be installed at around 450mm/18inches above the floor as CO2 is heavier than air and can collect at low levels. The alarm should be located either above the sensor at working head height (between 1800mm and 1950mm - 70 and 76 inches), or at the entrance to the area storing gas, to warn personnel of the CO2 status before entering the confined space. The alarm unit takes its power from the sensor unit which is connected to a standard electrical socket.
Ax60+ Kiosk Sensor Direct Connect Diagram 1. Sensor
|
|
Ax60+ Kiosk Alarm Unit Direct Connect Diagram 1. Strobe Light (White) |
|
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped.
The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.
Industries who use the Ax60+ Kiosk for CO2 gas safety
Gas detected | Carbon Dioxide (CO2) |
Sensor technology | Infrared |
Range | 0.1% to 5% |
Default Alarm set points |
USA regulations (NFPA 55, IFC, NBIC, OSHA and International/European regulations (EH40) (DIN 6653- |
Warm up time | 40 Seconds |
Response Time | 30 seconds to T90 |
Resolution | 0.01% |
Accuracy | ±2.5% of the alarm levels |
LED indicators | Green = Power |
IP Rating | IP55 |
Warranty | 5 years for both sensor and electronics |
Strobe | White LED strobe with an option to change to blue, red or amber filter |
Sounder | Min 80 dBA @3m / (9.8 feet) |
IP Rating | IP55 |
Cable | 2m included |
LED indicators | Green = Power, Amber = Fault |
By submitting your details you consent to their use in accordance with our Privacy Notice