The RHF range of silicon carbide heated high-temperature chamber furnaces comprises four chamber sizes, each available with three maximum operating temperatures of 1400 °C, 1500 °C and 1600 °C. Robust construction and high-quality elements provide rapid heating rates (typically reaching 1400 °C in under 40 minutes) and a long, reliable working life.
Designed for high-performance heating, these furnaces are ideal for a wide range of applications, including heat treatment and material testing. Featuring advanced temperature control systems for precise heating, each model in the RHF range ensures uniform heat distribution, exceptional reliability, and energy efficiency. Constructed with robust materials and engineered for safety.
The RHF furnaces offer an ergonomic design that simplifies operation and maintenance. Whether for research and development or industrial applications, the RHF range is the perfect choice for professionals seeking top-tier thermal processing solutions.
Standard features
Power Supplies for RHF Furnaces
A characteristic of the control systems used with silicon carbide elements results in a power supply which will be larger than expected, e.g., RHF 14/3 at 4500 W =
SIC Protection Tile Option
The RHF Chamber Furnace range is available with optional heating element protection tiles. When this option is specified, silicon carbide (SiC) tiles are added to the insulation assembly, positioned on both sides of the chamber to create a barrier between the working chamber and the heating elements. This will protect the heating elements from potentially harmful contaminants that might be placed in the chamber.
The addition of the heating element protection tiles option reduces the width of the internal chamber and the maximum operating temperature. The table below shows the amended technical data.
Application Examples
NOTE: The additional protection tiles reduce the width of the standard chamber and reduce the maximum temperature achievable in the chamber.
Options (specified at time of order)
We're happy to help! Please submit via the 'send enquiry' button at the top of the page to place an order, or email [email protected] or call +44 330 088 0595, and a member of the team will get back to you.
Technical Product Specifications
|
SKU / Model |
Series |
Model Size |
Max Temperature |
Capacity |
Product Type |
Voltage / Electrical Specification |
|
RHF1403-208SN |
RHF |
14/3 |
1400°C |
3 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1403-230SN |
RHF |
14/3 |
1400°C |
3 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1403-400TN |
RHF |
14/3 |
1400°C |
3 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1408-208SN |
RHF |
14/8 |
1400°C |
8 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1408-230SN |
RHF |
14/8 |
1400°C |
8 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1408-400TN |
RHF |
14/8 |
1400°C |
8 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1415-208SN |
RHF |
14/15 |
1400°C |
15 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1415-208TX |
RHF |
14/15 |
1400°C |
15 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1415-230SN |
RHF |
14/15 |
1400°C |
15 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1415-230TX |
RHF |
14/15 |
1400°C |
15 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1415-400TN |
RHF |
14/15 |
1400°C |
15 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1435-208TX |
RHF |
14/35 |
1400°C |
35 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1435-230TX |
RHF |
14/35 |
1400°C |
35 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1435-400TN |
RHF |
14/35 |
1400°C |
35 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1503-208SN |
RHF |
15/3 |
1500°C |
3 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1503-230SN |
RHF |
15/3 |
1500°C |
3 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1503-400TN |
RHF |
15/3 |
1500°C |
3 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1508-208SN |
RHF |
15/8 |
1500°C |
8 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1508-208TX |
RHF |
15/8 |
1500°C |
8 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1508-230SN |
RHF |
15/8 |
1500°C |
8 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1508-230TX |
RHF |
15/8 |
1500°C |
8 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1508-400TN |
RHF |
15/8 |
1500°C |
8 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1515-208SN |
RHF |
15/15 |
1500°C |
15 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1515-208TX |
RHF |
15/15 |
1500°C |
15 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1515-230SN |
RHF |
15/15 |
1500°C |
15 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1515-230TX |
RHF |
15/15 |
1500°C |
15 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1515-400TN |
RHF |
15/15 |
1500°C |
15 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1535-208TX |
RHF |
15/35 |
1500°C |
35 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1535-230TX |
RHF |
15/35 |
1500°C |
35 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1535-400TN |
RHF |
15/35 |
1500°C |
35 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1603-208SN |
RHF |
16/3 |
1600°C |
3 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1603-230SN |
RHF |
16/3 |
1600°C |
3 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1603-400TN |
RHF |
16/3 |
1600°C |
3 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1608-208SN |
RHF |
16/8 |
1600°C |
8 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1608-208TX |
RHF |
16/8 |
1600°C |
8 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1608-230SN |
RHF |
16/8 |
1600°C |
8 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1608-230TX |
RHF |
16/8 |
1600°C |
8 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1608-400TN |
RHF |
16/8 |
1600°C |
8 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1615-208SN |
RHF |
16/15 |
1600°C |
15 litre |
Chamber Furnace |
200–210 V, single-phase + N |
|
RHF1615-208TX |
RHF |
16/15 |
1600°C |
15 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1615-230SN |
RHF |
16/15 |
1600°C |
15 litre |
Chamber Furnace |
220–240 V, single-phase + N |
|
RHF1615-230TX |
RHF |
16/15 |
1600°C |
15 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1615-400TN |
RHF |
16/15 |
1600°C |
15 litre |
Chamber Furnace |
380–415 V, three-phase + N |
|
RHF1635-208TX |
RHF |
16/35 |
1600°C |
35 litre |
Chamber Furnace |
200–210 V, three-phase, N1 + N |
|
RHF1635-230TX |
RHF |
16/35 |
1600°C |
35 litre |
Chamber Furnace |
220–240 V, three-phase, N1 + N |
|
RHF1635-400TN |
RHF |
16/35 |
1600°C |
35 litre |
Chamber Furnace |
380–415 V, three-phase + N |
| RHF Range - Front-Loading Chamber Furnaces | Standard Voltages | ||||||
| -120SN | -208SN | -208TX | -230SN | -230TX | -400TN | ||
| 110 - 120 V single phase |
200 - 210 V single phase |
200 - 210 V three phase no N |
220 - 240 V single phase |
220 - 240 V three phase no N |
380 - 415 V three phase + N |
||
| RHF1403-volts | RHF 14/3, 1400°C, 3 litre | - | o | - | o | - | o |
| RHF1408-volts | RHF 14/8 1400°C, 8 litre | - | o | - | o | - | o |
| RHF1415-volts | RHF 14/15 1400°C, 15 litre | - | - | o | - | o | o |
| RHF1435-volts | RHF 14/35 1400°C, 35 litre | - | - | o | - | o | o |
| RHF1503-volts | RHF 15/35 1500°C, 35 litre | - | o | - | o | o | o |
| RHF1508-volts | RHF 15/8 1500°C, 8 litre | - | - | o | o | o | o |
| RHF1515-volts | RHF 15/15 1500°C, 15 litre | - | - | o | o | o | o |
| RHF1535-volts | RHF 15/35 1500°C, 35 litre | - | - | o | - | o | o |
| RHF1603-volts | RHF 16/3 1600°C, 3 litre | - | o | - | o | - | o |
| RHF1608-volts | RHF 16/8 1600°C, 8 litre | - | - | o | - | o | o |
| RHF1615-volts | RHF 16/15 1600°C, 15 litre | - | - | o | - | o | o |
| RHF1635-volts | RHF 16/35 1600°C, 35 litre | - | - | o | - | o | o |
| More options are available than are listed on these product-specific pages. - page 117.2 for probe thermocouples, gas safety system, temperature indicators and iTools software |
Key • = Default o = Option available - = Not available |
||||||
| Temperature controller options | Models | ||||||||||||
| RHF 14/3 | RHF 14/8 | RHF 14/15 | RHF 14/35 | RHF 15/3 | RHF 15/8 | RHF 15/15 | RHF 15/35 | RHF 16/3 | RHF 16/8 | RHF 16/15 | RHF 16/35 | ||
| &02-301 | 301 single-ramp PID controller | • | • | • | • | • | • | • | • | • | • | • | • |
| &02-301-3016 | Upgrade from 301 to EPC3016P1 1x 24 segment programmer | o | o | o | o | o | o | o | o | o | o | o | o |
| &02-301-CT1-1Z | Upgrade from 301 to CC-T1 touchscreen temperature programmer for single-zone products |
o | o | o | o | o | o | o | o | o | o | o | o |
| &02-301-3008P10 | Upgrade from 301 to EPC3008P10 10x 24 segment programmer | o | o | o | o | o | o | o | o | o | o | o | o |
| &02-NanoPR | Upgrade to NanoDAC PR | o | o | o | o | o | o | o | o | o | o | o | o |
| Built-in features and options - control options | |||||||||||||
| TMP-DIGOT-F | Digital over-temperature protection | o | o | o | o | o | o | o | o | o | o | o | o |
| TMP-&06-CS3 | Cascade control: chamber furnaces over 1200°C (requires an appropriate probe thermocouple & sheath) |
o | o | o | o | o | o | o | o | o | o | o | o |
| &08-232 | RS232 Communications | o | o | o | o | o | o | o | o | o | o | o | o |
| TMP-CALIB-CF11 | Single temperature, single position factory calibration of workspace for chamber furnaces, using equipment traceable to national standards. Please specify temperature (up to 1100°C maximum) and position when ordering. |
o | o | o | o | o | o | o | o | o | o | o | o |
| TMP-CALIB-CF15 | Single temperature, single position factory calibration of workspace for chamber furnaces, using equipment traceable to national standards. Please specify temperature (up to 1550°C maximum) and position when ordering. Price includes installation of 12mm ID thermocouple access port. |
o | o | o | o | o | o | o | o | o | o | o | o |
| &08-06-01 | Temperature alarm relay connection (please specify alarm temperature) | o | o | o | o | o | o | o | o | o | o | o | o |
| &08-06-02 | Program segment output | o | o | o | o | o | o | o | o | o | o | o | o |
| &08-06-04 | Audible alarm with separate cancel button | o | o | o | o | o | o | o | o | o | o | o | o |
| &08-06-05 | Audible alarm on overtemperature with separate cancel button | o | o | o | o | o | o | o | o | o | o | o | o |
| &14-R-132 | Built-in digital temperature indicator (132 series) for Type R thermocouples | o | o | o | o | o | o | o | o | o | o | o | o |
| &08-TYPE-X | Panel-mounted thermocouple socket for connection to spare Nanodac recording channel (please specify thermocouple type: X = K, N, R, B, 2) |
o | o | o | o | o | o | o | o | o | o | o | o |
Key
• = Default
o = Option available
- = Not available
Please note:
• Only available with CC-T1 or Nanodac instruments
• Only available for 301 controller, which must also be ordered with the overtemperature protection option
• Not available on 301 instruments
• Can only be ordered with &08-06-01 or &08-06-02
• Uses 2 phases of a 3-phase and neutral power supply
• Nanodac instruments have 3 spare thermocouple input channels, which can be configured to record temperature data from additional thermocouples (cascade control & O2 monitor options each use one channel)
By submitting your details you consent to their use in accordance with our Privacy Notice