At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates.
Gasmaster 1 | Gasmaster 4 | |
Size | 288 x 278 x 110mm (11.3 x 10.9 x 4.3 inches) | |
Weight | 4.5kg (10lbs) | |
Enclosure material | Back-box: cast aluminium Front cover: ABS (flame retardant) |
|
Ingress protection | IP65 | |
Power | 100-240Vac 50-60Hz or 20-30Vdc, 60W max |
|
Battery back-up | 1.2Ah batteries fitted internally | |
Operating temperature | -10°C to +50°C (14°F to +122°F) | |
Inputs | Gas One 2 or 3 wire 4-20mA gas detector (sink or source) or mV pellistor flammable gas detector | One to four 2 or 3 wire 4-20mA gas detectors (sink or source) or mV pellistor flammable gas detectors |
Fire One loop of up to 20 conventional smoke/heat detectors or manual call points, or one flame detector (4-20mA or digital contact signal) | One to four loops of up to 20 conventional smoke/heat detectors or manual call points, or one to four flame detectors | |
ESU For use with one Crowcon ESU fan | ||
Remote inhibit/retest Via normally open contact | ||
Outputs | Relays DPCO contacts rated 250Vac 8A Low alarm. High alarm. Fault. Alarm relays can be set for rising or falling alarms. Hysteresis can be adjusted on low alarms |
Low alarm and high alarm per channel plus common low, high and fault. Alarm relays can be set for rising or falling alarms. Hysteresis can be adjusted on low alarms |
A/V alarm drive 12Vdc or 24Vdc 650mA max. drive. Suitable for +ve or -ve switched alarms | ||
Analogue 4-20mA (current source, max. loop resistance 700?) or 1-5Vdc (min. load 50k? ) | 4-20mA for each channel (current source, max. loop resistance 700?) or 1-5Vdc (min. load 50k?) | |
Serial link RS-485 Modbus RTU for monitoring and control via DCS/SCADA/PLC systems | ||
Communications port | Optional port for PC configuration and event log upload | |
Event logging* | Time-stamped log of up to 300 alarms, fault or system intervention activities | |
Panel indication | LCD back-lit display shows gas level (in ppb, ppm, % volume or % LEL units), and scrolling alpha-numeric status indication. LED’s for Alarm, Fault, Power and Warning. Integral 85dB sounder (at 10cm) |
|
Approvals | EMC: EN50270, EN60945, FCC: CFR 47 Part 15; ICES – 003 ATEX: May be used in a non-hazardous area as part of Intrinsically Safe System conforming to EN60079-25 Baseefa 05Y0090/1 |
|
Functional safety | Validated to IEC61508 SIL2 |
*Event log access requires a Gasmaster PC communications kit and communications port (see Accessories
By submitting your details you consent to their use in accordance with our Privacy Notice