The Teledyne Detcon 700 sensor electronics are completely protected and immune to water ingress and corrosion. The sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. The 700 Series intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.
Electrical Classification (FP, TP, IR, PI and DM Series)
Class I, Div 1, Groups B, C, D; Class I, Zone 1, Group IIB+H2 (ATEX)
Electrical Classification (DM, O2, PI Series)
Class I, Div 1, Groups A, B, C, D; Class I, Zone 1, Group IIC (ATEX)
Integration Solutions Include:
Remote Control/Alarm Relay Module (RAM)
Hart Module
*Certifications listed below vary based on product. See individual documentation for specifics.
Gasses:
AsH3 B2H6 BR2 C2H2 C2H4 C2H4O C2H6O C3H6 C3H6O C3H8 C3H8O C4H10 C4H10O C4H6 C5H12 C6H14 C6H6 C7H8 C8H10 CH20 CH3OH CH3SH CH4 CH4S Cl2 ClO2 CO CO2 F2 GEH4 H2 H2S HBr HCl HCN HF N2H4 NH3 NO NO2 O2 O3 PH3 SiH4 SO2 VOC
Features and Benefits:
The 700 Series industrial gas detectors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics.
CHEMFET MOS Solid State Technology
Electrochemical Technology
Catalytic Technology
Infrared Technology
Electrochemical Technology
Photo Ionization
Electrochemical Technology
Infrared Technology
Input Voltage
11.5-28 VDC standard
Power Consumption
<2 watts typical
Outputs
Linear 4-20 mA DC
RS-485 Modbus™-RTU
Electrical Classification
Explosion Proof
FP-700, TP-700, IR-700-CH, IR-700-CO2:
- Class I, Division 1, Groups B, C, D
- Class I, Zone 1, Group IIB+H2 (ATEX)
DM-700 Toxics, DM-700-O2, PI-700:
- Class I, Division 1, Groups A, B, C, D
- Class I, Zone 1, Group IIC (ATEX)
Safety Approvals
CSA/NRTL (US OSHA Certified)
ATEX
GOST
INMETRO
CNEX
PESO
ABS
Dimensions
7” High x 2 1/8” Diameter (sensor only)
Weight
2 Lbs
Functional Safety Rating
IEC 61508 SIL2 Certified (IR, TP, FP, DM)
Exida assessed SIL2 (FMEDA)
Performance Approvals
IR-700, FP-700 to ISA 12.13, CSA #152
TP-700, DM-700 to ISA 92.0.01
Accuracy/Repeatability
FP-700: ±3% 0-50% LEL; ±5% 50-100%
TP-700: ±10% of reading or ±2 ppm (greater of)
DM-700-O2: ±2% full scale
IR-700-CH: ±3% 0-50% LEL; ±5% 50-100% LEL
IR-700-CO2: ±5% full scale
PI-700: ±10% of reading; ±2.5% of range (greater of)
DM-700 (toxics): ±2% full scale
Response/Clearing Time
FP-700: T50 <10 seconds; T90 <30 seconds
TP-700: T50 <30 seconds; T80 <60 seconds
DM-700-O2: T90 <20 seconds
IR-700-CH: T50 <10 seconds; T90 <30 seconds
IR-700-CO2: T50 <15 seconds; T90 <40 seconds
PI-700: T50 <10 seconds; T90 <30 seconds
DM-700 (toxics): Contact factory for specific gases
Operating Humidity Range (Continuous)
FP-700: 0-99% RH non-condensing
TP-700: 15-100% RH non-condensing
DM-700-O2: 0-99% RH non-condensing
IR-700-CH: 0-99% RH non-condensing
IR-700-CO2: 0-99% RH non-condensing
PI-700: 0-100% non-condensing
DM-700 (toxics): typically 10-90% RH contact factory for specific gases
700 Series Catalytic Combustible Gas Detection Sensor Assemblies | |
Catalytic versions | |
967-525520-100 | FP-700 Catalytic LEL Gas Sensor Assembly no condulet |
967-521520-100 | FP-700 Catalytic LEL Gas Sensor Assembly alum. condulet |
967-524520-100 | FP-700 Catalytic LEL Gas Sensor Assembly 316SS condulet |
9H7-521520-100 | FP-700 Catalytic LEL Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-524520-100 | FP-700 Catalytic LEL Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-521520-100 | FP-700 Catalytic LEL Gas Sensor w/RAM Assembly alum. condulet |
9R7-524520-100 | FP-700 Catalytic LEL Gas Sensor w/RAM Assembly 316SS condule |
9K7-521520-100 | FP-700 Catalytic LEL Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-524520-100 | FP-700 Catalytic LEL Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series Infrared Combustible Hydrocarbon Gas Detection Sensor Assemblies | |
Infrared versions | |
967-215520-100 | IR-700 Infrared LEL Gas Sensor Assembly no condulet |
967-211520-100_ | IR-700 Infrared LEL Gas Sensor Assembly alum. condulet |
967-214520-100_ | IR-700 Infrared LEL Gas Sensor Assembly 316SS condulet |
9H7-211520-100 | IR-700 Infrared LEL Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-214520-100 | IR-700 Infrared LEL Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-211520-100 | IR-700 Infrared LEL Gas Sensor w/RAM Assembly alum. condulet |
9R7-214520-100 | IR-700 Infrared LEL Gas Sensor w/RAM Assembly 316SS condulet |
9K7-211520-100 | IR-700 Infrared LEL Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-214520-100 | IR-700 Infrared LEL Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series IR CO2 Gas Detection Sensor Assemblies 0-5% range | |
Infrared versions | |
967-405520-005 | IR-700-CO2 Infrared Gas Sensor Assembly no condulet |
967-401520-005 | IR-700-CO2 Infrared Gas Sensor Assembly alum. condulet |
967-404520-005 | IR-700-CO2 Infrared Gas Sensor Assembly 316SS condulet |
9H7-401520-005 | IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-404520-005 | IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-401520-005 | IR-700-CO2 Infrared Gas Sensor w/RAM Assembly alum. condulet |
9R7-404520-005 | IR-700-CO2 Infrared Gas Sensor w/RAM Assembly 316SS condulet |
9K7-401520-005 | IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-404520-005 | IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series IR CO2 Gas Detection Sensor Assemblies 10-100% range | |
Infrared versions | |
967-425520-100 | IR-700-CO2 Infrared Gas Sensor Assembly no condulet |
967-421520-100 | IR-700-CO2 Infrared Gas Sensor Assembly alum. condulet |
967-424520-100 | IR-700-CO2 Infrared Gas Sensor Assembly 316SS condulet |
9H7-421520-100 | IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-424520-100 | IR-700-CO2 Infrared Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-421520-100 | IR-700-CO2 Infrared Gas Sensor w/RAM Assembly alum. condulet |
9R7-424520-100 | IR-700-CO2 Infrared Gas Sensor w/RAM Assembly 316SS condulet |
9K7-421520-100 | IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-424520-100 | IR-700-CO2 Infrared Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series MOS Hydrogen Sulfide Gas Detection Sensor Assemblies | |
Semi-Conductor versions | |
967-015520-100 | TP-700 Solid State MOS H2S Sensor Assembly no condulet |
967-011520-100 | TP-700 Solid State MOS H2S Gas Sensor Assembly alum. condulet |
967-014520-100 | TP-700 Solid State MOS H2S Gas Sensor Assembly 316SS condulet |
9H7-011520-10 | TP-700 Solid State MOS H2S Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-014520-100 | TP-700 Solid State MOS H2S Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-011520-100 | TP-700 Solid State MOS H2S Gas Sensor w/RAM Assembly alum. condulet |
9R7-014520-100 | TP-700 Solid State MOS H2S Gas Sensor w/RAM Assembly 316SS condulet |
9K7-011520-100 | TP-700 Solid State MOS H2S Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-014520-100 | TP-700 Solid State MOS H2S Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series VOC Gas Detection Sensor Assemblies Low Range (0-20ppm) | |
Except when Benzene is the target gas, then use PM version | |
PID | |
967-PB5520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly no condulet |
967-PB1520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly alum. condulet |
967-PB4520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly 316SS condulet |
9H7-PB1520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-PB4520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-PB1520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor w/RAM Assembly alum. condulet |
9R7-PB4520-010 | PI-700-VOC Volatile Organic Compound Gass Sensor w/RAM Assembly 316SS condulet |
9K7-PB1520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-PB4520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor w/Hart-RAM Assembly 316SS condulet |
700 Series VOC Gas Detection Sensor Assemblies Hi Range (20-1000ppm) | |
PID | |
967-PM5520-01K | PI-701-VOC Volatile Organic Compound Sensor Assembly |
967-PM1520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor Assembly alum. condulet |
967-PM4520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor Assembly 316SS condulet |
9H7-PM1520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor w/Hart bridge Assembly alum. condulet |
9H7-PM4520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor w/Hart bridge Assembly 316SS. condulet |
9R7-PM1520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor w/RAM Assembly alum. condulet |
9R7-PM4520-01K | PI-701-VOC Volatile Organic Compound Gass Sensor w/RAM Assembly 316SS condulet |
9K7-PM1520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor w/Hart-RAM Assembly alum. condulet |
9K7-PM4520-01K | PI-701-VOC Volatile Organic Compound Gas Sensor w/Hart-RAM Assembly 316SS condulet |