Honeywell Analytics Chemcassette Toxic Gas Detection

SKU
HA-Chemcassette

Chemcassette is the unique trademarked name by Honeywell Analytics for a calibration free toxic gas detection method that uses an optical scanning system to detect the presence of a gas by the color change on a special chemically impregnated paper tape.

Features and Benefits

  • Visible proof of a gas release event
  • Fast response time
  • Low false alarm occurrence

Quick Specs

  • Greater sensitivity (detection down to parts per billion levels)
  • Superior selectivity (less cross-interference with other gases)
  • Stability (consistent, repeatable operation)

Highly specific, the Chemcassette technology reacts extremely fast the many hazardous gases to the presence of parts per billion (ppb). Currently over 200,000 points of gas detection are maintained by the Chemcassette sensing technology at any given time around the World as some of the most critical safety applications possible.

Each Chemcassette is manufactured to traceable ISO 9000 manufacturing standards by a world class team of highly trained chemists. Each batch is calibrated with the ultra-pure gas at nationally accepted standards that are traceable. The end user does not have to provide calibration facilities themselves thereby saving cost and reducing the risks to their own staff.

Efficient high volume manufacturing techniques means that there is always available Chemcassette in stock that can be shipped to anywhere across the World so that our customers are never left without adequate safety cover. Application support with our expert gas detection chemists is available by phone and e-mail and is supported with many years of technical application notes and helps to diagnose common support issues.

Should there be any concern regarding the performance of an individual Chemcassette, a free of charge evaluation will be performed to trouble shoot the observed scenario using the "Customer Discrepancy Report" CDR an award winning quality management system. Completed by a customer every CRD is guaranteed a full response and the outcome is reported directly back to the end user to ensure a complete resolution process.

Each Chemcassette is backed with a full warranty and we have over 20 years of experience owing to the quality control of its proven sensing technology.

SKU

Description

SP Chemcassettes For TLD-1, SPM, Series 7100 and System 16 Monitoring Systems

    • 706002 Ammonia
    • 706042 Aliphatic Amines/Ammonia
    • 711314 Bromine
    • 704006 Chlorine/Chlorine Dioxide (1)
    • 704007 Chlorine/Oxidizers (1)
    • 700506 Diisocyanates
    • 1750-9306 Fluorine
    • 708013 Hydrazines
    • 705502 Hydrides
    • 702505 Hydrogen Chloride-for Series 7100 (ppm level)
    • 704510 Hydrogen Cyanide-for TLD-1 and SPM Monitors
    • 700278 Hydrogen Peroxide
    • 701012 Hydrogen Sulphide
    • 705505 Mineral Acids
    • 703012 Nitrogen Dioxide
    • 704514 Ozone
    • 702020 Phosgene
    • 709528 Aromatic Amines/PPD
    • 705015 Sulphur Dioxide
    • 705027 Sulphur Dioxide, Low Level
    LP Chemcassettes - For Series 7100 and System 16 only
    • 711342 Aliphatic Amines/Ammonia
    • 711302 Chlorine/Chlorine Dioxide
    • 711309 Diisocyanates
    • 1830-9306 Fluorine
    • 711300 Hydrides
    • 711304 Hydrogen Sulphide
    • 711337 Mineral Acids (1)
    • 711305 Nitrogen Dioxide (2)
    • 711307 Phosgene
    CM4 Chemcassette - For the Model CM4 Toxic Gas Monitor
    • 874342 Aliphatic Amines/Ammonia
    • 874007 Chlorine (monitors up to 16 days)
    • 1874-9306 Fluorine
    • 874347 Hydrazine
    • 874300 Hydrides
    • 874510 Hydrogen Cyanide (monitors up to 16 days)
    • 874304 Hydrogen Sulphide
    • 874337 Mineral Acids
    • 874307 Phosgene
    • 874568 Sulphur Dioxide

    EGM Chemcassettes - For the Model EGM only

    • 856342 Aliphatic Amines/Ammonia
    • 856302 Chlorine/Chlorine Dioxide
    • 856300 Hydrides
    • 856337 Mineral Acids
    • 856307 Phosgene

    Vertex Chemcassettes - For Vertex only

      • 1295-0221 Aliphatic Amines/Ammonia
      • 1295-0220 Fluorine (for F2, NO2)
      • 1295-0300 Hydrides
      • 1295-0222 Hydrogen Cyanide (monitors up to 2 weeks)
      • 1295-0225 Mineral Acids
      • 1295-0552 Sulphur Dioxide

      Extended Play XP Chemcassettes -for 1 to 3 months Service Life

      • 1295-0227 XPV for Chlorine (Vertex)
      • 1830-9308 XPL for Chlorine (System 16)
      • 1874-9308 XPC for Chlorine (CM4)
      • 1740-9308 XPS for Chlorine (SPM)
      • 1756-9308 XPE for Chlorine (EGM)
      • 1750-9308 XPT for Chlorine (TLD)
      • 1295-0226 XPV for Hydrides (Vertex)
      • 1830-9300 XPL for Hydrides (System 16)
      • 1874-9300 XPC for Hydrides (CM4)
      • 1740-9300 XPS for Hydrides (SPM)
      • 1756-9300 XPE for Hydrides (EGM*)
      • 1750-9300 XPT for Hydrides (ChemKey-TLD**)
      • 1295-0228 XPV for Phosgene (Vertex)
      • 1874-9307 XPC for Phosgene (CM4)
      • 1740-9307 XPS for Phosgene (SPM)
      • 1756-9307 XPE for Phosgene (EGM)
      • 1295-0405 XPV for Ammonia (Vertex)
      • 1830-9309 XPL for Ammonia (System 16)
      • 1874-9309 XPC for Ammonia (CM4)
      • 1740-9309 XPS for Ammonia (SPM)
      • 1756-9309 XPE for Ammonia (EGM)
      • 1295-0507 XPV for Mineral Acids (Vertex)
      • 1874-9310 XPC for Mineral Acids (CM4)
      • 1740-9310 XPS for Mineral Acids (SPM)
      • 1750-9310 XPT for Mineral Acids (TLD)

      Extended Play XP4 Chemcassettes -for 4 Months Service Life

      • 1257-9308 XP4-V for Chlorine (Vertex)
      • 1258-9308 XP4-C for Chlorine (CM4)
      • 1257-9300 XP4-V for Hydrides (Vertex)
      • 1258-9300 XP4-C for Hydrides (CM4)
      • 1257-9307 XP4-V for Phosgene (Vertex)
      • 1258-9307 XP4-C for Phosgene (CM4)
      • 1257-9309 XP4-V for Ammonia (Vertex)
      • 1258-9309 XP4-C for Ammonia (CM4)
      • 1257-9310 XP4-V for Mineral Acids (Vertex)
      • 1258-9310 XP4-C for Mineral Acids (CM4)