Product Features
  • Detects more than 35 gases error-free
  • Improved visibility and ease of use
  • Easy installation

  • Flow Rate: 500 mL/min
  • Transport Time: 2 to 30 seconds maximum
  • Sample Line Tubing: 0.125 in ID x 0.25 in OD
Delivery options

At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates. 

  • We can ship consignments of all shapes and sizes and hazardous content across the UK and worldwide. Most of our orders are sent via DHL, however sometimes we may use other couriers.
  • If you are purchasing a laboratory product online you can find out the price of shipping checkout. If you are obtaining a quote for a product, then we will email you
    with our best shipping prices along with your quote.
  • Please see our delivery page for full information

Honeywell Analytics Midas Gas Detector

SKU
HA-Midas_Gas_Detector

The Midas Gas Detector by Honeywell Analytics uses reliable sensor technology to detect many key toxic ambient and flammable gases in a plant.

Key Features

  • Detects more than 35 gases error-free
  • Improved visibility and ease of use
  • Easy installation

The device monitor points up to 100 feet (30 meters) away while using patented technology to regulate flow rates and ensure gas detection error-free. Use of advanced robotics, the Midas Gas Detector use of advanced robotics thanks to Honeywell's offers unbeatable quality and reliability.

Improved visibility and ease of use: The Midas Gas Detector is equipped with bright LED lights and an interactive interface, intuitive and that provides instant alerts as alarm levels to gas readings. Also included in the interface is the protected menus as password for calibration, tests and configuration.

Easy installation: Compact in size with a metal chassis that is easy-to-handle, the Midas Gas Detector is simple to install. This is especially important owing to the crowded, complex process environments where space is at a premium.

The Numerous applications: This includes aerospace, light industrial manufacturing, semiconductor processing, waste water, university laboratories and more.

Additional Benefits

  • Over 35 gases available with extended 2 year warranty*
  • Smart sensor cartridge with on board ‘e-calibration’ certificate
  • 3 built in relays (Form C) for Alarm 1, 2 and Fault
  • Power over Ethernet (PoE) communication
  • Keypad interface and remote web browser interface
  • Optional Midas Pyrolyzer module that connects to any Midas Gas Detector
  • Password protected menu levels to preserve system integrity
  • Bright LEDs and intuitive icon driven, large multicolor backlit LCD display
  • Factory-calibrated sensors to reduce need for frequent gas testing
  • Isolated 0-22 mA analog output with fault and event reporting
  • Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
  • Robust extractive pump system (2 year lifetime) sampling up to 100 feet
  • CE marked for total immunity to Radio Frequency Interference
  • Reflex® sensor health check for improved safety
  • TempraSureTM temperature compensation technology as appropriate
  • Event logging to review sensor history

SKU

Description

Midas Extractive Transmitter for Universal Gas Detection

  • MIDAS-T-004 Midas Extractive Transmitter (Generation 2)
Pyrolyzer Module for NF3 Gas Detection
  • MIDAS-T-00P Midas Pyrolyzer Module

Midas High Temperature Pyrolyzer Module

  • MIDAS-T-0P3 Midas High Temperature Pyrolyzer Module

LonWorks Module for Midas Transmitter Connection

  • MIDAS-T-LON Midas LonWorks Interface Module

Quad LonWorks Module for External Transmitter Connection

  • MIDAS-A-035 Midas Quad LonWorks Module

Midas Sensor Cartridges

  • MIDAS-S-NH3 Ammonia (NH3)
  • MIDAS-S-ASH Arsine (AsH3), Germane (GeH4)
  • MIDAS-S-HCL Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr) Hydrogen Chloride (HCl)
  • MIDAS-S-HFL Boron Trfluoride (BF3), Hydrogen Fluoride HF (low level), Tungsten Hexafluoride (WF6) (Low)***
  • MIDAS-S-HFX Boron Trifluoride (BF3), Hydrogen Fluoride (HF), Nitrogen Trifluoride (NF3)* Tungsten Hexafluoride (WF6)
  • MIDAS-S-BR2 Bromine (Br2), Chlorine Dioxide (ClO2)
  • MIDAS-S-COX Carbon Monoxide (CO)
  • MIDAS-S-HAL Chlorine (Cl2), Fluorine (F2)
  • MIDAS-S-B2H Diborane (B2H6)
  • MIDAS-S-H2X Hydrogen (H2)
  • MIDAS-S-HCN Hydrogen Cyanide (HCN)
  • MIDAS-S-H2S Hydrogen Sulphide (H2S)
  • MIDAS-S-LEL Hydrogen (H2), Methane (CH4)
  • MIDAS-S-NOX Nitric Oxide (NO)
  • MIDAS-S-NO2 Nitrogen Dioxide (NO2)
  • MIDAS-S-O2X Oxygen (O2)
  • MIDAS-S-O3X Ozone (O3)
  • MIDAS-S-O3H Ozone (O3) (high Level)
  • MIDAS-S-PH3 Phosphine (PH3)
  • MIDAS-S-SHL Silane (SiH4) (Low Level)
  • MIDAS-S-SHX Silane (SiH4), Disilane (Si2H6)
  • MIDAS-S-SO2 Sulphur Dioxide (SO2)
  • MIDAS-S-TEO TEOS
  • MIDAS-S-XCF Difluoromethane (CH2F2), Hexafluorobutadiene (C4F6)**, Octofluorocyclopentene (C5F8)**, 0-40 ppm, 0-240 ppm, 0-40 ppm
  • MIDAS-S-XHF Nitrogen Trifluoride (NF3)*, Methyl Fluoride (CH3F)**, 0-40ppm, 0-120ppm
  • MIDAS-E-NH3 Ammonia (NH3) 9-100 ppm
  • MIDAS-E-ASH Arsine (AsH3), Germane (GeH4) 18-200 ppb 70-800 ppb
  • MIDAS-E-HCL Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) 0.72-8 ppm
  • MIDAS-E-HFU Hydrogen Fluoride (HF), Tungsten Hexafluoride (WF6) 0.42-2 ppm 0.22-2 ppm
  • MIDAS-E-HFL Boron Trfluoride (BF3), Hydrogen Fluoride HF (low level), Tungsten Hexafluoride (WF6) (Low)*** 0.18-2 ppm
  • MIDAS-E-HFX Boron Trifluoride (BF3), Hydrogen Fluoride (HF), Nitrogen Trifluoride (NF3)* Tungsten Hexafluoride (WF6) 0.72-8 ppm 1.05-12 ppm 3.6-40 ppm 1.05-12 ppm
  • MIDAS-E-BR2 Bromine (Br2), Chlorine Dioxide (ClO2) 0.036-0.4 ppm
  • MIDAS-E-CFX Difluoromethane (CH2F2), Hexafluorobutadiene (C4F6)**, Methyl Fluoride (CH3F)**, Octofluorocyclopentene (C5F8)**, 16-240 ppm 3-40 ppm 8-120 ppm 3-40 ppm
  • MIDAS-E-CFH Hexafluorobutadiene (C4F6)** 7.2-80 ppm
  • MIDAS-E-COX Carbon Monoxide (CO) 9-100 ppm
  • MIDAS-E-HAL Chlorine (Cl2) Fluorine (F2)" 0.18-2 ppm 0.36-4 ppm
  • MIDAS-E-B2H Diborane (B2H6) 0.036-0.4 ppm
  • MIDAS-E-H2X Hydrogen (H2) 90-1000 ppm
  • MIDAS-E-HCN Hydrogen Cyanide (HCN) 1.8-20 ppm
  • MIDAS-E-H2S Hydrogen Sulphide (H2S) 3.6-40 ppm
  • MIDAS-E-LEL Hydrogen (H2), Methane (CH4) 6.5-100% LEL
  • MIDAS-E-NOX Nitric Oxide (NO) 9-100 ppm
  • MIDAS-E-NO2 Nitrogen Dioxide (NO2) 1.05-12 ppm
  • MIDAS-E-O2X Oxygen (O2) 0.2-25% v/v
  • MIDAS-E-O3X Ozone (O3) 0.036-0.4 ppm
  • MIDAS-E-O3H Ozone (O3) High Level) 0.036-0.7 ppm
  • MIDAS-E-PH3 Phosphine (PH3) 110-1200 ppb
  • MIDAS-E-SHL Silane (SiH4) (Low Level) 0.18-2 ppm
  • MIDAS-E-SHX Silane (SiH4), Disilane (Si2H6) 1.8-20 ppm
  • MIDAS-E-SO2 Sulphur Dioxide (SO2) 0.7-8 ppm
  • MIDAS-E-TEO TEOS 3.6-40 ppm
  • MIDAS-E-XCF Difluoromethane (CH2F2), Hexafluorobutadiene (C4F6)**, Octofluorocyclopentene (C5F8)** 0-40 ppm 0-240 ppm 0-40 ppm
  • MIDAS-I-CO2 Carbon Dioxide IR cartridge 0.15-5.0%, 0.15%-0,2% v/v
  • MIDAS-I-N2O Nitrous Oxide IR cartridge 100-1000 ppm
  • MIDAS-E-XHF Nitrogen Trifluoride (NF3)*, Methyl Fluoride (CH3F)** 0-40ppm 0-120ppm

Midas Transmitter and Sensor Cartridge Kits

  • MIDAS-K-NH3 Ammonia (NH3) 9-100 ppm
  • MIDAS-K-ASH Arsine (AsH3), Germane (GeH4) 18-200 ppb 70-800 ppb
  • MIDAS-K-HCL Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) 0.72-8 ppm
  • MIDAS-K-HFU Hydrogen Fluoride (HF), Tungsten Hexafluoride (WF6) 0.42-2 ppm 0.22-2 ppm
  • MIDAS-K-HFX Boron Trifluoride (BF3), Hydrogen Fluoride (HF), Nitrogen Trifluoride (NF3)*, Tungsten Hexafluoride (WF6) 0.72-8 ppm 1.05-12 ppm 3.6-40 ppm 1.05-12 ppm
  • MIDAS-K-HFL Boron Trfluoride (BF3), Hydrogen Fluoride HF (low level), Tungsten Hexafluoride (WF6) (Low)*** 0.18-2 ppm
  • MIDAS-K-BR2 Bromine (Br2), Chlorine Dioxide (ClO2) 0.036-0.4 ppm
  • MIDAS-K-CFX Difluoromethane (CH2F2), Hexafluorobutadiene (C4F6)**, Methyl Fluoride (CH3F)**, Octofluorocyclopentene (C5F8)**, 16-240 ppm 3-40 ppm 8-120 ppm 3-40 ppm
  • MIDAS-K-COX Carbon Monoxide (CO) 9-100 ppm
  • MIDAS-K-HAL Chlorine (Cl2), Fluorine (F2) 0.18-2 ppm 0.36-4 ppm
  • MIDAS-K-B2H Diborane (B2H6) 0.036-0.4 ppm
  • MIDAS-K-H2X Hydrogen (H2) 90-1000 ppm
  • MIDAS-K-HCN Hydrogen Cyanide (HCN) 1.8-20 ppm
  • MIDAS-K-H2S Hydrogen Sulphide (H2S) 3.6-40 ppm
  • MIDAS-K-LEL Hydrogen (H2), Methane (CH4) 6.5-100% LEL
  • MIDAS-K-NOX Nitric Oxide (NO) 9-100 ppm
  • MIDAS-K-NO2 Nitrogen Dioxide (NO2) 1.05-12 ppm
  • MIDAS-K-O2X Oxygen (O2) 0.2-25% v/v
  • MIDAS-K-O3X Ozone (O3) 0.036-0.4 ppm
  • MIDAS-K-O3H Ozone (O3) (High Level) 0.036-0.7 ppm
  • MIDAS-K-PH3 Phosphine (PH3) 110-1200 ppb
  • MIDAS-K-SHL Silane (SiH4) (Low Level) 0.18-2 ppm
  • MIDAS-K-SHX Silane (SiH4), Disilane (Si2H6) 1.8-20 ppm
  • MIDAS-K-SO2 Sulphur Dioxide (SO2) 0.7-8 ppm
  • MIDAS-K-TEO TEOS

Accessories and Options

  • 1283K1090 Duct Adapter for 1/4" O.D. tubing for 4-16" round ducts
  • 0235-0128 Flexible Conduit 21" - length
  • 0235-0163 Flexible Conduit 27" - length
  • 0310-2055 Flexible Conduit 36" - length
  • MIDAS-A-001 Midas Operating Manual and Quick Start Guide (English)
  • MIDAS-A-010 Replacement RJ45 restraining strap
  • MIDAS-A-030 Single point POE power injector for 1 Midas (US power cord)
  • MIDAS-A-011 8 Port POE switch (120VAC) for 3 MIDAS or 2 Midas/Pyrolyzer units
  • MIDAS-A-032 Midas "L" Bracket for Vertical Mounting
  • MIDAS-A-033 Midas Optional Weather Shield for MIDAS "L" Bracket
  • MIDAS-A-036 Midas DIN Rail Mounting Kit
  • MIDAS-A-039 Ventilated Midas Top Cover for Pyrolyzer Applications
  • MIDAS-A-102 Midas Generation 1 Replacement Cover (Black)
  • MIDAS-A-103 Midas Vented Cover (Black) Generation 2

Sample Tubing

  • 1991-0136 Inlet Tubing, FEP Teflon 100' 1/4 x 1/8
  • 1991-0137 Exhaust Tubing, Poly 100' 1/4" OD
  • MIDAS-A-031 Top access tubing adaptor for Midas inlet connector

Consumables

  • MIDAS-A-007 Replacement Midas internal sample pump and mounting bracket
  • MIDAS-A-009 Replacement Internal Air Filter for Midas Universal Gas Detector
  • 1830-0080 Freon Filter for NF3 Pyrolyzing Gas Detector (extended life). Note: Not for use with C4F6, C5F8, CH3F, CH2F2 pyrolyzers
  • 1830-0027 Freon Filter for NF3 Pyrolyzing Gas Detector. Note: Not for use with C4F6, C5F8, CH3F, CH2F2 pyrolyzers
  • 780248 End of Line Particulate Filter. For use as End of Line filter for Non-Corrosive gases
  • 1830-0055 End of Line Particulate Filter for Corrosive Gases, Reusable. This reusable filter housing provides protection against particulate build up in the sample line when monitoring for Corrosive Gases. Replaceable filter element (P/N 0235-1072) purchased separately
  • 1991-0147 End of Line Particulate Filter for Corrosive Gases, Disposable. This disposable filter provides protection against particulate build up in the sample line when monitoring for Corrosive Gases
  • 0235-0095 Union Fitting - use to connect disposable filter to end of line
Write Your Own Review
You're reviewing:Honeywell Analytics Midas Gas Detector
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice