The Honeywell Searchline Excel is a hazardous area certified flammable Infrared Open Path Gas Detector. This gas detector is ideal for applications in the harshest environments where reliability and performance are critical. The Searchline Excel provides a vast area of coverage, a very high speed of response and no unseen failure modes.
The unit consists of both a transmitter and receiver, for mounting at each end of the path that is to be monitored. There are three Searchline Excel versions available: Short Range (5-40m), Medium Range (40-120m) and Long Range (120-200m). Hazardous area approvals include European (ATEX), North American (UL) and Canadian (CSA). The receiver output is 3 3-wire 4-20mA selectable sink or source.
Please note that Searchline Excel CSA covers Methane-calibrate versions. A calibration has to be ordered with every Searchline Excel.
The fundamental design of Searchline Excel has remained the same since its original launch and it continues to lead the field.
Searchline Excel is immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning.
The patented optical design used in Searchline Excel has proven itself as the only solution available that fully addresses all the challenges of open-path gas detection. Unlike some competitive devices, it does not try to hide fundamental design inadequacy with the use of software masks that can compromise the unit’s ability to detect gas.
Searchline Excel employs a patented double-band pass filter that fully compensates for all types of fog and/or rain, thereby allowing it to continue to operate accurately and reliably in all climatic conditions.
Sample and reference detector alignment:
• Reduced sensitivity to alignment
• Guaranteed performance
• Reduced sensitivity to partial obscuration
Improved handheld software:
• Simple confirmation of alignment
• Visual indication of target and current signal levels
• Compatible with existing systems
Improved telescope:
• High Power Rifle Telescope
• Easier to align with greater zoom and magnification
• Robust shock-resistant design
Features & Benefits:
• Fast speed of response provides the earliest warning
• High sensitivity allows low alarm set points
• Alignment-free design makes installation simple
• Alignment-free design makes installation simple
Spec | |
---|---|
Available Gases |
Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Butadiene |
Range | 0 to 5 LEL.m |
Recommended Alarm Settings | (Low) 1.0 LEL.m; (high) 3.0 LEL.m |
Path Lengths | Short Range 5m to 40m (15ft to 130ft.), Medium Range 40m to 120m (130ft to 390ft.) and Long Range 120m to 200m (390ft to 650ft.) |
Speed of Response | T90 less than 3 seconds. (under normal operating conditions) |
Output Signal | 4-20mA (maximum loop resistance 600 ohms; source & sink available) and RS485 21mA Over range 4-20mA Normal operation (0 to 5 LEL.m) 3mA(1) Dirty optics 2.5mA(1) Beam blocked 2mA(1) 0mA Fault |
Digital Output | Modbus RS485 multi drop. Using DX100 (M) or XNX Universal Transmitter with Modbus option |
Operating Temperature | -40°C to +65°C (-40°F to 150°F) |
Operating Humidity | 0 to 99% RH (non-condensing) |
Operating Pressure | 91.5 to 105.5 KPa (915 to 1055 mbar) (non-compensated) |
Warm-up Time | Less than 5 minutes (operational), or less than 1 hour (fully stabilised) |
Power Supply | 18V to 32VDC |
Power Consumption | Short Range Tx: 3.5W / 5.0W *maximum. Medium and Long Range Tx: 10W / 13W* maximum. Rx: 8W maximum. |
Enclosure Material | 316 stainless steel |
Weight (inc. mounting bracket) | Short Range TX: 3.5kg Medium and Long Range TX: 7kg RX: 3.5kg |
Vibration | 2 to 60Hz, max ptp amplitude 1mm. |
Misalignment Tolerance | Short Range ±0.5º (±~35cm at 40m). Medium Range ±0.5º (±~104cm at 120m). Long Range ±0.5º (±~170cm at 200m) |
EMC Standards | EN50270 |
Performance Approval | FM performance approved |
Safety Approval | ATEX Transmitter: II 2 G Ex d op is IIC T5 (Tamb -40°C to +65°C) Gb II 2 G Ex d op is IIC T6 (Tamb -40°C to +40°C) Gb Receiver: II 2 G Ex d IIC T5 (Tamb -40°C to +65°C) Gb II 2 G Ex d IIC T6 (Tamb -40°C to +40°C) Gb IECEx Transmitter: Ex d op is IIC T5 (Tamb =-40°C to +65°C) Gb Ex d op is IIC T6 (Tamb =-40°C to +40°C) Gb Receiver: Ex d IIC T5 (Tamb -40°C to +65°C) Gb Ex d IIC T6 (Tamb -40°C to +40°C) Gb UL: Class 1 Groups B, C, D and Class 1 Zone 1 AEx d IIB + Hydrogen (Amb -40°C to +65°C) CSA: Class 1 Div 1 groups B, C, D, T5 and Exd IIC T5 (Amb -40°C to +65°C) FM: Class 1 Div 1 groups B, C, D & T5 (Tamb -40 to +65°C) Other: GOST Independently assessed to IEC61508 |
IP Rating | IP66 and IP67 |
Please see the different part numbers for the Searchline Excel below. If you are able to refer to a part number when requesting a quote it will help us get back to you more quickly.
Excel Short Range 5m - 40m (15ft - 130ft) |
---|
|
Excel Medium Range 40m - 120m (130ft - 390ft) |
|
Excel Long Range 120m - 200m (390ft - 650ft) |
|
Gas Calibrations |
|
Alignment Kits |
|