Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Flammable (catalytic or infrared), toxic and oxygen versions are available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Honeywell Sensepoint XCD Gas Detector & Transmitter

SKU
HoneywellAnalyticsSensepointXCD

The Honeywell Sensepoint XCD Gas Detector & Transmitter range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors.

    The standard XCD is an Ex-d gas detector suitable for use in Zone 1 environments and is available in 3 versions: flammable, oxygen and toxic. Each is supplied with a pre-installed stainless steel sensor cartridge and fully tested and calibrated ready for installation. Replacement sensor cartridges are available. Configuration and control of the unit is achieved through the use of a magnet removing the need to open the unit, while the tri-colour backlit display provides instant indication of the detector status at a glance.
      The XCD catalytic sensor can be used to detect flammable gases in the range of 0 to 100% LEL while the infrared (IR) sensor versions are available for the detection of methane in the range of 0 to 100% LEL, propane (with cross sensitivities to ethylene and butane) and Carbon Dioxide (CO2). Both sensors are used in conjunction with the flammable version of the transmitter.
        The electrochemical cell (EC) sensors are available for the detection of oxygen and toxic gases: Carbon Monoxide (CO), Hydrogen Sulphide (H2S), Nitrogen Dioxide (NO2) and Hydrogen (H2). Each detector is supplied with a pre-fitted sensor, nylon weather protection, a stainless-steel blanking plug, a magnetic wand, and hex keys. All transmitters are also available with Modbus interface as an option.

          Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.

            A tri-colour backlit LCD indicates the unit's status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

              All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry-standard 4-20mA output (sink or source selectable) and Modbus.

                The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarms at the control panel during maintenance.

                  Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either a conduit or cable with suitable mechanical protection. Two M20 or ¾"NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

                    Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy-to-replace plug-in sensors, downtime is also reduced and ongoing costs are minimised through the use of poison-resistant flammable sensors, poison-immune infrared Hydrocarbon sensors patented Surecell toxic sensors and Reflex sensor health checks.

    Instrument - ATEX/IECEx/CHINA Approval (316SS)
    • SPXCDASMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
    • SPXCDASMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
    • SPXCDASMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
    • SPXCDASMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry
    • SPXCDASMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry
    • SPXCDASMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry
    • SPXCDASMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry
    • SPXCDASMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
    • SPXCDASMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry
    Instrument - ATEX/IECEx/CHINA Approval (LM25)
    • SPXCDALMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
    • SPXCDALMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
    • SPXCDALMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
    • SPXCDALMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry
    • SPXCDALMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry
    • SPXCDALMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry
    • SPXCDALMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry
    • SPXCDALMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry
    • SPXCDALMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry
    Instrument - UL/CSA Approval (316SS)
    • SPXCDUSNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
    • SPXCDUSNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
    • SPXCDUSNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
    • SPXCDUSNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4"NPT Entry
    • SPXCDUSNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4"NPT Entry
    • SPXCDUSNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4"NPT Entry
    • SPXCDUSNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4"NPT Entry
    • SPXCDUSNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4"NPT Entry
    • SPXCDUSNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4"NPT Entry
    Instrument - UL/CSA Approval (LM25)
    • SPXCDULNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
    • SPXCDULNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
    • SPXCDULNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
    • SPXCDULNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry
    • SPXCDULNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4"NPT Entry
    • SPXCDULNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4"NPT Entry
    • SPXCDULNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4"NPT Entry
    • SPXCDULNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry
    • SPXCDULNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4"NPT Entry
    Instrument - ATEX/IECEx/CHINA Approval (316SS) with ModBus
    • SPXCDASMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
    • SPXCDASMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
    • SPXCDASMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
    • SPXCDASMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry, with ModBus
    • SPXCDASMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry, with ModBus
    • SPXCDASMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with ModBus
    • SPXCDASMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with ModBus
    • SPXCDASMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
    • SPXCDASMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry, with ModBus
    Instrument - ATEX/IECEx/CHINA Approval (LM25) with ModBus
    • SPXCDALMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
    • SPXCDALMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
    • SPXCDALMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
    • SPXCDALMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry, with ModBus
    • SPXCDALMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry, with ModBus
    • SPXCDALMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with ModBus
    • SPXCDALMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with ModBus
    • SPXCDALMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry, with ModBus
    • SPXCDALMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry, with ModBus
    Instrument - UL/CSA Approval (316SS) with ModBus
    • SPXCDUSNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4"NPT Entry, with ModBus
    • SPXCDUSNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4"NPT Entry, with ModBus
    Instrument - UL/CSA Approval (LM25) with ModBus
    • SPXCDULNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry, with ModBus
    • SPXCDULNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4"NPT Entry with ModBus
    Accessories
    • S3KCAL Calibration cup
    • SPXCDCC Collecting cone for use with lighter than air gases
    • SPXCDDMK Duct mounting kit
    • SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
    • SPXCDSDP Sunshade / Deluge Protection
    • 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved
    Sensepoint XCD Sensors (316 Stainless Steel)
    • SPXCDXSFXSS Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSRXSS Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSO1SS Oxygen 25.0%/Vol only
    • SPXCDXSHXSS Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)
    • SPXCDXSCXSS Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
    • SPXCDXSNXSS Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)
    • SPXCDXSG1SS Hydrogen 0-1000ppm only
    • SPXCDXSPXSS Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSB1SS Carbon Dioxide IR 0-2.00%VOL only
    Sensepoint XCD Transmitter (without Sensor)
    • SPXCDALMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry
    • SPXCDALMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, LM25 with M20 Entry
    • SPXCDALMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry
    • SPXCDASMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry
    • SPXCDASMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry
    • SPXCDASMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry
    • SPXCDALMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry and ModBus
    • SPXCDALMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter with LM25, M20 Entry, with ModBus
    • SPXCDALMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry and ModBus
    • SPXCDASMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry and ModBus
    • SPXCDASMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry and ModBus
    • SPXCDASMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry and ModBus
    • SPXCDULNTXO UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4"NPT Entry
    • SPXCDULNTXT UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4"NPT Entry
    • SPXCDULNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4"NPT Entry
    • SPXCDUSNTXO UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4"NPT Entry
    • SPXCDUSNTXT UL approved Sensepoint XCD Toxic Transmitter with 316SS, 3/4"NPT Entry
    • SPXCDUSNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4"NPT Entry
    • SPXCDULNTXOM UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4"NPT Entry and ModBus
    • SPXCDULNTXTM UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4"NPT Entry and ModBus
    • SPXCDULNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4"NPT Entry and ModBus
    • SPXCDUSNTXOM UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4"NPT Entry and ModBus
    • SPXCDUSNTXTM UL approved Sensepoint XCD Toxic Transmitter, 316SS with 3/4"NPT Entry and ModBus
    • SPXCDUSNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4"NPT Entry and ModBus
    Miscellaneous Spares
    • SPXCDDMF Replacement display module for Cat and IR
    • SPXCDDMT Replacement display module for O2 and Toxic
    • SPXCDDMFM Replacement display module (Cat and IR) with ModBus
    • SPXCDDMTM Replacement display module O2 and Toxic with ModBus
    • SPXCDTMF Replacement terminal module for Cat and IR
    • SPXCDTMO Replacement terminal module for O2
    • SPXCDTMT Replacement terminal module for Toxic
    • SPXCDMAG Magnet
    • SPXCDWP XCD Weather proof cap
    • SPXCDSRLS Sensor Retainer with locking screw
    • SPXCDAKS Allen key for stopper
    • SPXCDHWES Hex wrench for earth screw
    • SPXCDEBS Earth Bracket and screws
    Instrument - Sensepoint XCD RFD Transmitter
    • SPXCDASMRFD ATEX/IECEx and AP approved SP XCD RFD Transmitter with 316SS
    • SPXCDALMRFD ATEX/IECEx and AP approved SP XCD RFD Transmitter with LM25
    • SPXCDUSNRFD cCSAus approved SP XCD RFD Transmitter with 316SS, 3/4"NPT Entries
    • SPXCDULNRFD cCSAus approved SP XCD RFD Transmitter with LM25, 3/4" NPT Entries
    Instrument - Sensepoint XCD RFD Remote Plug-in Sensor and Socket
    • SPXCDXSRFXSS Sensepoint XCD RFD remote plug-in sensor and socket, flammable CAT 0-100%LEL (20,0 to 100.0%LEL)
    • SPXCDXSRRXSS Sensepoint XCD RFD remote plug-in sensor and socket, Methane IR 0-100%LEL (20,0 to 100.0%LEL)
    • SPXCDXSRPXSS Sensepoint XCD RFD remote plug-in sensor and socket, Propane IR 0-100%LEL (20,0 to 100.0%LEL)
    • SPXCDXSRB1SS Sensepoint XCD RFD remote plug-in sensor and socket, Carbon Dioxide IR 0-2.00%VOL only
    Instrument - Sensepoint XCD RFD Transmitter with ModBus
    • SPXCDASMRFDM ATEX/IECEx and AP approved SP XCD RFD Transmitter, 316SS, 2x M20 and 1x M25 entries, with ModBus
    • SPXCDALMRFDM ATEX/IECEx and AP approved SP XCD RFD Transmitter, LM25, 2x M20 and 1x M25 entries, with ModBus
    • SPXCDUSNRFDM cCSAus approved SP XCD RFD Transmitter with 316SS, 3/4"NPT Entries, with ModBus
    • SPXCDULNRFDM cCSAus approved SP XCD RFD Transmitter with LM25, 3/4" NPT Entries, with ModBus
    Accessories
    • SPXCDWP XCD Weather proof cap
    • S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
    • SPXCDCC Collecting cone for use with lighter than air gases
    • SPXCDDMK Duct mounting kit
    • SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
    • SPXCDSDP Sunshade / Deluge Protection
    • 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved
    Spares
    • SPXCDXSFXSS Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSRXSS Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSPXSS Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
    • SPXCDXSB1SS Carbon Dioxide IR 0-2.00%VOL only
    • SPXCDDMR XCD RFD Flam and IR Display Module
    • SPXCDDMRM XCD RFD Flam and IR Display Module, ModBus
    • SPXCDTMR XCD RFD Replacement Terminal Module
    • SPXCDMAG Magnet
    • SPXCDSRLS Sensor Retainer with locking screw
    • SPXCDAKS Allen key for stopper
    • SPXCDHWES Hex wrench for earth screw
    • SPXCDEBS Earth Bracket and Screws
    Instrument - Sensepoint XCD RTD 4-20mA Input Transmitter (Transmitter Only)
    • SPXCDASMTX4 ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with 316SS, M20 Entry
    • SPXCDALMTX4 ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with LM25, M20 Entry
    • SPXCDUSNTX4 cCSAus approved SP XCD RTD Transmitter with 316SS
    • SPXCDULNTX4 cCSAus approved SP XCD RTD Transmitter with LM25
    Instrument - Sensepoint XCD RTD 4-20mA Input Transmitter with ModBus (Transmitter Only)
    • SPXCDASMTX4M ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with 316SS, with ModBus
    • SPXCDALMTX4M ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with LM25, with ModBus
    • SPXCDUSNTX4M cCSAus approved SP XCD RTD Transmitter with 316SS, with ModBus
    • SPXCDULNTX4M cCSAus approved SP XCD RTD Transmitter with LM25, with ModBus
    Accessories and Spares
    • SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
    • SPXCDSDP Sunshade / Deluge Protection
    • SPXCDDM4 Sensepoint XCD RTD Toxic and O2 Display Module
    • SPXCDDM4M Sensepoint XCD RTD Toxic and O2 ModBus Display Module
    • SPXCDTM4 Sensepoint XCD RTD Replacement terminal module
    • SPXCDAKS Allen key for stopper
    • SPXCDHWES Hex wrench for earth screw
    • SPXCDEBS Earth Bracket and Screws
    • SPXCDMAG Magnet
    Write Your Own Review
    You're reviewing:Honeywell Sensepoint XCD Gas Detector & Transmitter
    Your Rating

    Sign up for our latest offers

    By submitting your details you consent to their use in accordance with our Privacy Notice