Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Common transmitter platform cuts stocking and procurement costs
  • Obtain maximum coverage in areas not easily accessible
  • Prevent false alarms with auto-inhibit during maintenance
  • Input voltage range: 16 to 32 VDC (24 VDC nominal)
  • Communication: RS485
  • Certified temperature range: 40° to +149°F (-40° to +65°C)
Delivery options

At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates. 

  • We can ship consignments of all shapes and sizes and hazardous content across the UK and worldwide. Most of our orders are sent via DHL, however sometimes we may use other couriers.
  • If you are purchasing a laboratory product online you can find out the price of shipping checkout. If you are obtaining a quote for a product, then we will email you
    with our best shipping prices along with your quote.
  • Please see our delivery page for full information

Honeywell Analytics Sensepoint XCD RTD

SKU
Honeywell-Analytics-Sensepoint-XCD-RTD
The Honeywell Analytics Sensepoint XCD RTD offers unrivalled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and mounting options, and onboard diagnostics. The XCD RTD makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas. You can mount the unit up to 100 feet from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored.

Get More Return on Investment from the Practical Advantages of XCD RTD. Sensepoint toxic and oxygen sensors detect a wide variety of industrial gases at common measuring ranges, adding flexibility to your gas monitoring program, reducing your parts procurement costs and expanding your safety net.

Remote gas monitoring has never been this easy and cost-effective. Mount the sensor as shown in the illustration and view gas safety status via the large tri-colour display on the transmitter, up to 100 feet away from the sensor. The advantages of this remote monitoring system are added safety, and reduced time spent on maintenance. There’s no need for your team to climb ladders or bring in specialized equipment to view gas concentration readings or to conduct a safety audit. What’s more, the removable sensor design of Sensepoint XCD RTD cuts downtime and eliminates the need for specialized training
Part Number Description
4-20mA Input Transmitter (Transmitter Only) 
SPXCDASMTX4 XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
SPXCDALMTX4 XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
SPXCDUSNTX4 XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4" NPT entries, painted 316SS
SPXCDULNTX4 XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4" NPT entries, painted LM25
4-20mA Input Transmitter with Modbus (Transmitter Only) 
SPXCDASMTX4M XCD RTD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry,
painted 316SS
SPXCDALMTX4M XCD RTD Transmitter, 4 to 20 mA and Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry,
painted LM25
SPXCDUSNTX4M XCD RTD Transmitter, 4 to 20 mA and Modbus output, cCSAus, 3 x 3/4" NPT entries, painted 316SS
SPXCDULNTX4M XCD RTD Transmitter, 4 to 20 mA and Modbus output, cCSAus, 3 x 3/4" NPT entries, painted LM25
XCD Accessories 
S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
SPXCDCC Collecting cone for use with lighter than air gases
SPXCDDMK Duct mounting kit
SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
SPXCDSDP Sunshade / Deluge Protection
00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - £ 73.00 UC
3 X 20mm Entries - ATEX Approved
90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube £ 1 21.00 UC
Connector to Gas Bottle
90068-C-8290 PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter
90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter
90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter
ADU300429 Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2"NPT (female)
RDU303029 Reducer, ATEX, Ex d e, 316SS, 3/4"NPT (male) to 1/2"NPT (female)
PDU300400 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug
PDU303000 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4" NPT Blanking Plug
X4S-2006662 Field Device Tag Label (Based on Drawing Number 90084-C-7013).
Material: 316 Stainless Steel (Supplied loose & to be assigned at site)
Dimensions: 80x20x1.2mm (LxHxD)
Text Height & Length: 1 row of 5mm engraved text (Max. Characters of 15 off).
Note: Upon purchase order placement, please state the text per each tag required
Write Your Own Review
You're reviewing:Honeywell Analytics Sensepoint XCD RTD
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice