Product Features
  • Continuous hazardous gas monitoring unit
  • Capable of monitoring up to 24 points using 3 analysers
  • Longer monitoring life with extended tapes (90 days)
  • Touch screen for easy data access
  • No dynamic calibration is required
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

The Honeywell Vertex M Hazardous Gas Monitor is an economical way to install, augment or upgrade a gas monitoring system for industries using toxic. It provides a flexible 8 to 24 points of monitoring for use with up to 3 Chemcassette® analysers or combination 1 pyrolizer analyser/1 universal Chemcassette® analyser; comes in a small, space-saving cabinet; 110V or 220V power options; and uses the industry’s most reliable toxic gas monitoring technology, colorimetric Chemcassette®, which shows proof of a gas response through a telltale stain on the Chemcassette® tape. The Vertex M integrates easily into a factory automation system or HMI to serve the semiconductor, PV, nano, special chemical, lab and other High-Tech/Industrial environments.


    Additional Features and Benefits:

    • ▪ Extended tapes (90 days) provide longer monitoring life
      • ▪ Additional pump and internal power module increase uptime
        • ▪ The software can be configured without taking the unit offline
          • ▪ Sampling points can be up to 400 feet (121m) from the monitor and routed to more than one analyser

            • Easy to Use:

              • ▪ Touch screen for easy access to data
                • ▪ Software updates via CD-ROM or network to all system components
                  • ▪ Configuration profile editing and data retrieval are all achievable without taking the unit offline
                    • ▪ Radio frequency identification tag (RFID) ensures Chemcassettes® are installed into the appropriately programmed analyser, eliminating human error
                      • ▪ On-line help system

                        • Security:

                          • ▪ Multiple levels of password protection
                            • ▪ Reconfigure the security setup without taking the unit offline

                              • Low Cost of Ownership:

                                • ▪ Small footprint and greater density of points reduce your cost per point
                                  • ▪ Eight points per analyser lower Chemcassette® costs
                                    • ▪ Maximised 24-point systems provide low cost per point as compared to other continuous monitors
                                      • ▪ One system monitors up to three gas families and more than 40 gases
                                        • ▪ You can split your sample into more than one analyser

                                          • Easy to Maintain:

                                            • ▪ Uses cost-effective XP Chemcassettes®, providing up to three months of continuous monitoring
                                              • ▪ Simplified replacement of Chemcassettes® and automated optics verification
                                                • ▪ No dynamic calibration required
                                                  • ▪ No flow balancing
                                                    • ▪ Easy access to analysers, pumps, power supplies and touch screens from the front panel
                                                      • ▪ Onscreen interactive electronic manual

                                                        • Advanced Communication:

                                                          • ▪ Built-in configurable PLCs with optional 64 relay contacts
                                                            • ▪ Standard OPC interface for easy integration into your existing factory automation system or HMI
                                                              • ▪ Optional Ethernet/CIP, LONWORKS®, DeviceNetTM, DF1Interface, PROFIBUS, Modbus Plus, Modbus/TCP or ControlNet outputs available
                                                                • ▪ Optional ChemCam camera permits viewing of stain, locally or remotely, for proof of gas event. The image is electronically saved for future retrieval
                                                                  • ▪ Optional remote control/viewing software enables total visualisation of the monitor screens at a remote PC

                                                                    • Features and Benefits:

                                                                      • ▪ Touch screen for easy data access
                                                                        • ▪ Low cost of ownership with Chemcassettes®
                                                                          • ▪ One system monitors up to 9 gas families/more than 40 gases

SKU

Description

Vertex M Configurations

  • 1290-0074 Vertex M with one (1) Universal Chemcassette analyser: This configuration contains a Vertex M Base Rack (220 VAC) with one (1) universal Chemcassette analyser, the data acquisition center, redundant pumps and power supplies, touch screen keyboard, all cable management and ancillary support necessary to install up to two (2) additional analysers, and an accessory kit. Accessory Kit includes backup CDs of all appropriate software, electronic manual, installation drawings, auxiliary analyser key and 50 feet (15m) of exhaust tubing

  • 1290-0075 Vertex M with one (1) Pyrolyser analyser: This configuration contains a Vertex M Base Rack (220 VAC) with one (1) pyrolyzer analyser, the data acquisition center, redundant pumps and power supplies, touch screen keyboard, all cable management and ancillary support necessary to install up to one (1) additional analysers, and an accessory kit. Accessory Kit includes backup CDs of all appropriate software, electronic manual, installation drawings, auxiliary analyser key and 50 feet (15m) of exhaust tubing

  • 1290-0072 Vertex M with one (1) Universal Chemcassette analyser: This configuration contains a Vertex M Base Rack (110 VAC) with one (1) universal Chemcassette analyser, the data acquisition center, redundant pumps and power supplies, touch screen keyboard, all cable management and ancillary support necessary to install up to two (2) additional analysers, and an accessory kit. Accessory Kit includes backup CDs of all appropriate software, electronic manual, installation drawings, auxiliary analyser key and 50 feet (15m) of exhaust tubing

  • 1290-0073 Vertex M with one (1) Pyrolyzer analyser: This configuration contains a Vertex M Base Rack (110 VAC) with one (1) pyrolyzer analyser, the data acquisition center, redundant pumps and power supplies, touch screen keyboard, all cable management and ancillary support necessary to install up to one (1) additional analysers, and an accessory kit. Accessory Kit includes backup CDs of all appropriate software, electronic manual, installation drawings, auxiliary analyser key and 50 feet (15m) of exhaust tubing

Vertex M Low Level HF Activation
  • 1295-0541 Low Level Hydrogen Fluoride (HF) Licensed Activation, per rack (for countries requiring a license)

  • 1290-0084 Low Level Hydrogen Fluoride (HF) Licensed Activation, per rack (for countries not requiring license)

Vertex M Base Rack

  • 1290-0071 220 VAC Vertex M Base Rack

  • 1290-0066 110 VAC Vertex M Base Rack

Vertex M Analysers

  • 1291-1001 Universal Chemcassette analyser: Each analyser can monitor up to eight (8) sample points

  • 1291-2001 Pyrolyzer analyser: This Analyser is specially designed to monitor Nitrogen Trifluoride (NF3) via conversion to Hydrogen Fluoride (HF) by an integral pyrolyzer. Each analyser can monitor up to eight (8) sample points. The Pyrolyzer analyser takes the place of two (2) adjoining Universal Chemcassette analysers

Serial Communication Interfaces

  • 1295-0329 DeviceNet Interface
  • 1295-0328 LonWorks Interface
  • 1295-0343 DF1 Interface
  • 1295-0275 Profibus Adapter
  • 1295-0330 Modbus Plus Interface (Note: Not compatible with Modbus/RTU)
  • 1295-0394 ControlNet Interface
  • 1295-0519 Ethernet/CIP Interface
  • 1295-0520 Modbus/TCP Interface
  • 1290-0078 4-20 mA Interface

Relay Options

  • 1290-0076 16 Channel Non-Isolated Relay Option Total of sixty-four (64) factory installed and field programmable Form A relays. Within each group of eight relays one side connected to a common terminal
  • 1290-0077 8 Channel Isolated Relay Option Total of thirty-two (32) factory installed and field programmable Form A relays. Each contact totally isolated

    Remote Software Options

    • 1295-0344 Active Display Server: Server software (installs on Vertex M): Connect one or more remote PCs to a Vertex M for remote viewing and control. Required to enable Active Display Floating Client Full Control. One per Vertex M rack required for remote operation

    • 1295-0233 Active Display Floating Client Full Control License: Client software (installs on PC): View and control the Vertex M interface from a single remote location at a time. One per remote viewing session is required. (Must order with 1295-0344)

    Chemcam

    • 1295-0230 Chemcam (one per analyser). Must be factory installed.

    Sample Line Integrity

    • 1295-0510 The Sample Line Integrity Kit for the Vertex M enables an automatic scheduled pressure test of each sample line to confirm integrity. Kit includes a software license, 8 check valves, and the associated accessories for a single analyser.

    Accessories

    • 1295K0523 Pack (25) stoppers for unused sample ports on top manifold of Vertex M

    • 1290K0064 Floor Mounting Option

    Sample Tubing

    • 0235-0157 Tubing, FEP Teflon 0.156" I.D.x 0.250" O.D. - 400 ft roll (121m) Standard tubing for Vertex M sample lines. The FEP Teflon (medium wall) tubing is less prone to kinking when turning a corner. The smaller I.D. means improved transport time over thin wall tubing
    • 102628 Tubing, FEP Teflon 0.190" I.D. x 0.250" O.D - 400 ft roll (121m) Alternate tubing for VertexTM samples lines. Used with Vertex M where longer sample line length for multiple analysers are required. Consult the transport time chart in the VertexTM Technical Handbook for additional information
    • 0235-0109 Tubing, FEP Teflon 0.190" I.D. x 0.250" O.D. - 1000 ft roll (304m) Alternate tubing for VertexTM samples lines. Used with Vertex M where longer sample line length for multiple analysers are required. Consult the transport time chart in the VertexTM Technical Handbook for additional information

    Duct Adapters

    • 1283K1090 Duct adapter for 1/4" O.D. tubing for 4-16" round ducts

    External Particulate Filters

    • 780248 End of line particulate filter. For use as end of line filter for non-corrosive gases
    • 1991-0147 End of line particulate filter for corrosive gases, disposable. This disposable filter provides protection against particulate build up in the sample line when monitoring for corrosive gases.
    • 1830-0055 End of line particulate filter for corrosive gases, reusable. This reusable filter housing provides protection against particulate build up in the sample line when monitoring for corrosive gases. Replaceable filter element (P/N 0235-1072) purchased separately
    • 0235-0095 Union fitting - use to connect disposable filter to end of line
    • 0235-1072 Replacement "corrosive" filter elements (pk 100). For use in 1830-0055 filter housing

    External Interferent Filters

    • 1295K0497 H2S in line scrubber filter (1 per individual inlet line). Up to 3 months use
    Write Your Own Review
    You're reviewing:Honeywell Vertex M Hazardous Gas Monitor
    Your Rating

    Sign up for our latest offers

    By submitting your details you consent to their use in accordance with our Privacy Notice