Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Capable of monitoring up to 72 points with 9 analysers
  • Touch screen for easy data access
  • Low cost of ownership with Chemcassettes®
  • One system monitors up to 9 gas families/more than 40 gases
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Honeywell Vertex Multi-Point Toxic Gas Monitoring System

SKU
HA-Vertex_Multi_Point

The Honeywell Vertex™ Multi-Point Toxic Gas Monitoring System combines the most advanced Chemcassette®, software and optics technologies into a flexible, reliable monitoring system with up to 72 points of gas detection. Start your Vertex™ System with as little as eight points. As your monitoring needs change, Vertex™ expands, offering you up to 72 points of continuous gas detection. Place your sampling points up to 400 feet (120 meters) from the system. There is a choice of universal analyser modules and/or pyrolyzer analysers. Vertex™ offers powerful, built-in system redundancy as standard equipment to effectively safeguard against downtime.


    Reliable:

    • ▪ Back-up pump and internal power module
      • ▪ Chemcassette® technology provides physical evidence of gas event
        • ▪ System data back-up. If the main data acquisition PC fails, analysers continue to monitor, log data and alarm
          • ▪ Drip resistant cap for system protection from overhead leaks
            • ▪ Automated leak test with line integrity option

              • Additional Features and Benefits


                  Easy to Use:

                  • ▪ Touch screen for easy access to data
                    • ▪ Software updates via CD-ROM or network to all system components
                      • ▪ Configuration profile editing and data retrieval are all achievable without taking the unit offline
                        • ▪ Radio frequency identification tag (RFID) ensures Chemcassettes® are installed into the appropriately programmed analyser, eliminating human error
                          • ▪ On-line help system

                            • Security:

                              • ▪ Multiple levels of password protection
                                • ▪ Reconfigure the security setup without taking the unit offline

                                  • Low Cost of Ownership:

                                    • ▪ Vertex’s smaller footprint and greater density of points reduce your cost per point
                                      • ▪ Eight points per analyser lower Chemcassette® costs
                                        • ▪ Maximised 72-point systems provide low cost per point as compared to other continuous monitors
                                          • ▪ One system monitors up to nine gas families and more than 40 gases
                                            • ▪ You can split your sample into more than one analyser

                                              • Easy to Maintain:

                                                • ▪ Vertex uses cost-effective XP Chemcassettes®, providing up to three months of continuous monitoring
                                                  • ▪ Simplified replacement of Chemcassettes® and automated optics verification
                                                    • ▪ No dynamic calibration required
                                                      • ▪ No flow balancing
                                                        • ▪ Easy access to analysers, pumps, power supplies and touch screens from the front panel
                                                          • ▪ Onscreen interactive electronic manual with integral video

                                                            • Advanced Communications:

                                                              • ▪ Built-in configurable PLCs with optional 176 relay contacts
                                                                • ▪ Standard OPC interface for easy integration into your existing factory automation system or HMI
                                                                  • ▪ Optional Ethernet/CIP, LONWORKS®, DeviceNetTM, DF1Interface, PROFIBUS, Modbus Plus, Modbus/TCP or ControlNet, or isolated 4-20mA outputs available>
                                                                    • ▪ Optional ChemCam camera permits viewing of stain, locally or remotely, for proof of gas event. The image is electronically saved for future retrieval
                                                                      • ▪ Optional remote control/viewing software enables total visualisation of the monitor screens at a remote PC

                                                                        • Features and Benefits:

                                                                          • ▪ Touch screen for easy data access
                                                                            • ▪ Low cost of ownership with Chemcassettes®
                                                                              • ▪ One system monitors up to 9 gas families/more than 40 gases

SKU

Description

Vertex Base Rack Enclosure

  • 1290-0019 Vertex Base Rack Enclosure: This enclosure contains the data acquisition center, redundant pumps and power supplies, touch screen keyboard, all cable management and ancillary support necessary to install up to nine (9) Analysers, and an accessory kit. Accessory kit includes backup CDs of all appropriate software, electronic manual, installation drawings, auxiliary analyser key and 50 feet (15m) of exhaust tubing. This unit should be ordered with one of the relay or serial communications.
Vertex Analysers
  • 1291-1001 Universal Chemcassette analyser: Each analyser can monitor up to eight (8) sample points. Note: The analyser does not include a Chemcassette. For each analyser order the appropriate Chemcassette.

  • 1291-2001 230V Pyrolyzer analyser (to be ordered with new systems): This monitor is specially designed to detect Nitrogen Trifluoride (NF3) via conversion to Hydrogen Fluoride (HF) by an integral pyrolyzer. Each analyser can monitor up to eight (8) sample points. The selection of each Pyrolyzer analyser takes the place of two (2) adjoining Chemcassette analysers. A maximum of three (3) Pyrolyzer analysers can be put into one rack. This Pyrolyzer analyser can only be installed in the new enclosure (Part Number 1290-0019). Note: For each analyser order the appropriate Chemcasssette.

  • 1291-2000 Pyrolyzer analyser: This monitor is specially designed to detect Nitrogen Trifluoride (NF3) via conversion to Hydrogen Fluoride (HF) by an integral pyrolyzer. Each analyser can monitor up to eight (8) sample points. The selection of each Pyrolyzer analyser takes the place of two (2) adjoining Chemcassette analysers. A maximum of three (3) Pyrolyzer analysers can be put into one rack. This Pyrolyzer analyser is only to be ordered for analyser expansion of the older syle enclosures (P/N 1290- 0300 and 1290-0302). Note: The analyser does not include a Chemcassette. Order the appropriate Chemcasssette.

Vertex Low Level HF Activation

  • 1295-0541 Low Level Hydrogen Fluoride (HF) Licensed Activation, per rack (for countries requiring a license)
  • 1290-0084 Low Level Hydrogen Fluoride (HF) Licensed Activation, per rack (for countries not requiring license)

Serial Communications Interfaces

  • 1295-0329 DeviceNet Interface Option
  • 1295-0328 LonWorks Interface Option
  • 1295-0343 DF1 Interface Option
  • 1295-0275 Profibus Adapter Option
  • 1295-0330 Modbus Plus Interface Option (Note: Not compatible with Modbus/RTU)
  • 1295-0394 ControlNet Interface Option
  • 1295-0519 Ethernet/CIP Communications Option
  • 1295-0520 Modbus/TCP Communications Option

Relay Options

  • 1290-0020 16 Channel Relay Option (must be ordered with new style enclosure [P/N1290-0019]). Total of 176 factory installed and field programmable Form A relays. Within each group of eight relays one side connected to a common terminal

  • 1290-0021 8 Channel Relay (isolated) Option (must be ordered with new style enclosure [P/N1290-0019]). Total of 88 factory installed and programmable. Each contact totally isolated

  • 1290-0014 16 Channel Relay Option (only used with old style enclosures P/N 1290-0300 or 1290-0302). Factory installed and programmable. Within each group of eight relays one side connected to a common terminal

  • 1290-0015 8 Channel Relay (isolated) Option (only used with old style enclosures P/N 1290-0300 or 1290-0302). Factory installed and programmable. Each contact totally isolated

Midas Sensor Cartridges

  • MIDAS-E-H2S Hydrogen Sulphide (H2S) 3.6-40 ppm
  • MIDAS-E-LEL Hydrogen (H2), Methane (CH4) 6.5-100% LEL
  • MIDAS-E-NOX Nitric Oxide (NO) 9-100 ppm
  • MIDAS-E-NO2 Nitrogen Dioxide (NO2) 1.05-12 ppm
  • MIDAS-E-O2X Oxygen (O2) 0.2-25% v/v
  • MIDAS-E-O3X Ozone (O3) 0.036-0.4 ppm
  • MIDAS-E-O3H Ozone (O3) High Level) 0.036-0.7 ppm
  • MIDAS-E-PH3 Phosphine (PH3) 110-1200 ppb
  • MIDAS-E-SHL Silane (SiH4) (Low Level) 0.18-2 ppm
  • MIDAS-E-SHX Silane (SiH4), Disilane (Si2H6) 1.8-20 ppm
  • MIDAS-E-SO2 Sulphur Dioxide (SO2) 0.7-8 ppm
  • MIDAS-E-TEO TEOS 3.6-40 ppm
  • MIDAS-E-XCF Difluoromethane (CH2F2), Hexafluorobutadiene (C4F6)**, Octofluorocyclopentene (C5F8)** 0-40 ppm 0-240 ppm 0-40 ppm
  • MIDAS-I-CO2 Carbon Dioxide IR cartridge 0.15-5.0%, 0.15%-0,2% v/v
  • MIDAS-I-N2O Nitrous Oxide IR cartridge 100-1000 ppm
  • MIDAS-E-XHF Nitrogen Trifluoride (NF3)*, Methyl Fluoride (CH3F)** 0-40ppm 0-120ppm

Remote Software Options

  • 1295-0344 Active Display Server: Provides the capability to connect one or more remote PCs to the Vertex for remote viewing and/or control of Vertex activity. This software is installed on the Vertex and is required to enable any of the options below. (One required for each Vertex for remote operation)

  • 1295-0233 Active Display Floating Client Full Control License: Provides the capability to view and control Vertex activity from one remote location at a time. Same as above except that writing to the Vertex is enabled. (Must order with 1295-0344)

Chemcam

    • 1295-0230 Chemcam (One per analyser) Note: Must be factory installed
    • 1295-0401 Chemcam rack kit (One required per rack, for any Chemcam installation) Note: Recommended Factory install

    Sample Line Integrity

    • 1295-0510 Line integrity kit for the Vertex gas monitor system enabling automatic scheduled pressure test of each sample line for integrity check. Kit includes software license per separate analyser and 8 check valves and associated accessories per analyser unit. Note: A separate line integrity kit needs to be ordered for each analyser in each Vertex rack; price does not include labor to install check valves at client site.

    Miscellaneous Options

    • 1295-0229 Floor mounting option

    • 1295K0523 Pack (25) stoppers for unused sample ports on top manifold of Vertex and Vertex MTM

    • 1295-0322 Manifold, 4-Port

    • 1295-0261 Keyboard kit (old style enclosures P/N 1290-0300 or 1290-0301)

    • 1295-0484 Keyboard kit - new style enclosure

      Accessories

      • 1295-0528 External-mount AC Connection Junction Box

      • 0060-1020 Transformer 480/230 VAC 60 Hz, 5 KVA

      • 0060-1021 Transformer 208/240 VAC 60 Hz, 5 KVA

      • 1998M0391 Vertex Technical Handbook on CD-ROM

      Sample Tubing

      • 0235-0157 Tubing, FEP Teflon 0.156" I.D.x 0.250" O.D. - 400 ft roll (121m) Standard Tubing for Vertex MTM Sample lines. The FEP Teflon (medium wall) tubing is less prone to kinking when turning a corner. The smaller I.D. means improved transport time over thin wall tubing
      • 102628 Tubing, FEP Teflon 0.190" I.D. x 0.250" O.D - 400 ft roll (121m) Alternate tubing for Vertex samples lines. Used with Vertex MTM where longer sample line length for multiple analysers are required. Consult the transport time chart in the Vertex Technical Handbook for additional information
      • 0235-0109 Tubing, FEP Teflon 0.190"" I.D. x 0.250"" O.D. - 1000 ft roll (304m) Alternate tubing for Vertex samples lines. Used with Vertex MTM where longer sample line length for multiple analysers are required. Consult the transport time chart in the Vertex Technical Handbook for additional information

      Duct Adapters

      • 1283K1090 Duct Adapter for 1/4" O.D. tubing for 4-16" round ducts

      External Interferent Filters

      • 780248 End of line particulate filter. For use as end of line filter for non-corrosive gases ?11.00 1991-0147 End of line particulate filter for corrosive gases, disposable. This disposable filter provides protection against particulate build up in the sample line when monitoring for corrosive gases
      • 1830-0055 End of line particulate filter for corrosive gases, reusable. This reusable filter housing provides protection against particulate build up in the sample line when monitoring for corrosive gases. Replaceable filter element (P/N 0235-1072) purchased separately
      • 0235-0095 Union fitting - use to connect disposable filter to end of line
      • 0235-1072 Replacement "corrosive" filter elements (pk 100). For use in 1830-0055 filter housing

      External Particulate Filters

      • 1295K0497 H2S in line scrubber filter (1 per individual inlet line). Up to 3 months use.
      Write Your Own Review
      You're reviewing:Honeywell Vertex Multi-Point Toxic Gas Monitoring System
      Your Rating

      Sign up for our latest offers

      By submitting your details you consent to their use in accordance with our Privacy Notice