Honeywell XNX Universal Transmitter

SKU
Honeywell Analytics XNX Universal Transmitter

The Honeywell XNX Universal Transmitter deploys various detection technologies including point flammable detectors (both catalytic and infrared type), toxic and Oxygen electrochemical cell type detectors and open path infrared detectors. The XNX provides a common transmitter interface to all of these and can be configured to provide industry-standard signal outputs to match the individual requirements of each application or the preferred site standard. If site output standards change, the XNX can be reconfigured to provide the new required output. The Honeywell XNX has also been future-proofed by having the ability to have other output modules fitted as new output standards are developed and adopted by the industry.

Having a common transmitter platform for all your gas detectors brings further benefits. Common tools and installation methods simplify and reduce the cost of installation. The common user interface makes operations faster to learn and easier to navigate, thus reducing the time needed for training and the chance of incorrectly interpreting messages or changing settings. Common spare parts also mean reduced maintenance spares stock levels and cost for all detectors.

The Honeywell XNX Universal Transmitter allows you to apply the most appropriate gas detection technologies for each application, standardise the interface to those detectors and have the flexibility to provide the required signal outputs. With XNX the answer is always yes.

The Honeywell Analytics XNX Universal Transmitter supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs (saving customers time and money).

 

Flexible:

  • Compatible with all Honeywell Analytics gas sensors
  • Allows selection of best sensor technology for each application
  • Choice of all industry-standard output signals
  • Ability to adapt configuration as the site needs change
  • Future-proofed for any new output standards
     

Common Transmitter Platform:

  • Simplified and reduced cost of installation
  • Reduced training time and cost
  • Less chance of misinterpreting messages
  • There is less chance of incorrectly changing settings
  • Reduced maintenance, spares, stock and cost
     

Easy to Use:

  • Easy-read multilingual backlit LCD with text, bar graph, digits and icons
  • Local or remote sensor mounting options
  • Selectable sink, source or isolated 4-20mA output to suit preferred wiring topology
  • HART communications as standard for remote diagnostics/configuration
     

Reduced Operational Costs:

  • Fully configurable via non-intrusive magnetic switches
  • No hot work permit is needed
  • Hot swap toxic and Oxygen sensor cartridges
  • Serviceable catalytic and IR sensors
  • Auto-inhibit during maintenance
     

Friendly Installation:

  • Integral surface mounting lugs or optional pipe or ceiling mounting brackets
  • Plug-in "POD" module removes to give access to the terminal area
  • Removable plug/socket type terminal blocks for ease of wiring
     

Typical Applications:

  • Offshore oil and production platforms
  • Oil and gas exploration and drilling
  • Refineries
  • Chemical and petrochemical plants
  • Onshore oil and gas terminals
  • Gas transmission
  • Power stations
XNX Transmitter  
Use High specification universal transmitter for use with a wide range of Honeywell Analytics local or remote gas detectors for the detection of flammable, toxic and Oxygen gas hazards. Suitable for use in Zone 1 and 2 or Zone 21 and 22 hazardous areas, and North American Class I and II Division 1 or 2 areas.
Construction
Material  Housing: 5-coat marine finish painted aluminium alloy or 316 stainless steel
Weight (Approx.) Aluminium alloy: 2.8kg (6.2lbs). 316 stainless steel: 5kg (11lbs)
Mounting Surface mount via integral mounting lugs. Optional pipe mounting kit suitable for Ø100mm to 150mm (Ø4” to 6”) pipe. Optional ceiling mounting bracket
Entries 5 conduit/cable entries (2 right, 2 left, 1 bottom). Entry size M25 for ATEX/IECEx versions or ¾"NPT for UL/CSA certified versions
Dimensions 160mm x 197mm x 114mm (6.1" x 7.8" x 4.5")
Environmental
IP Rating IP66 in accordance with EN60529:1992. NEMA 4X
Operating Temperature -40ºC to +65ºC (-40ºF to +149ºF)
Operating Humidity 0-99%RH (non condensing)
Operating Pressure 90-110kPa
Storage Conditions -40ºC to 75ºC (-40ºF to 167ºF), 0-99% non-condensing
Electrical
Input Voltage Range EC and mV versions 16 to 32Vdc, IR version 18 to 32 Vdc (24Vdc nominal) 
Max Power Consumption XNX EC (Toxic): 6.2 watts
 XNX mV (Catalytic or IR cell): 6.5 watts
 XNX IR with Searchpoint Optima Plus: 9.7 watts
 XNX IR with Searchline Excel Receiver: 13.2 watts
Current Output

Fully configurable isolated 4-20mA & HART® output module providing current sink, current source and isolated modes of operation (supports HART® 6.0 protocol)
 supplied as standard
 Default current output settings:

≥0.0<1.0mA Fault 3mA Fault/Warning
 4.0 mA to 20.0mA Normal gas measurement 4-20mA Normal gas measurement
 2.0 mA or 4.0 mA (17.4mA) Inhibit (during configuration/user settings) 22.0mA Maximum over range
 The available output range for Inhibit, Warning, Beam Blocked and Low Signal is from 1 to 4mA. For an over range condition, the range is 20 to 22mA

4-20mA Signal Accuracy +/-1% Full Scale
Functions Supported
by HART®

Gas reading
Gas name and units of measurement
4-20mA signal level
General/device information
Installation
Configuration
Forcing of 4-20mA output

Detailed sensor information including:
Optical signal level
Dynamic reserve (Searchline Excel only)
Raw reading
24V supply voltage
Temperature

Calibration and configuration status
Detailed fault and warning information
Fault and alarm history
Zero calibration

Terminals Cage style pluggable with retaining screws for wire diameter 0.5mm2
 to 2.5mm2
 (approx. 20AWG to 14AWG)
Certification 
European ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db
International IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb Ex tb [ia IIIC Da] IIIC T85 Db
North American UL: Class I, Div 1, Groups A, B, C, and D; Class II, Div. 1 Groups F & G / Class 1, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21
 FM: AEx D [ia IIC] IIB + H2 T6 -40°C ≤Tamb ≤65°C
Canadian CSA: Class I, Div 1, Groups B, C, and D; Class II, Div. 1 Groups F & G / Class I, Zone 1 Groups IIB + H2
EMC EN50270:2006 EN61000-6-4:2007
Performance Europe – ATEX, EN45544, EN50104, EN50271:2010, EN13980, EN60079-29-1
 North America – UL 913, UL 1203, CSA 22.2 No. 152
 IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
Local IS HART® Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable ‘hot’ connection of HC275/375 HART® or equivalent hand held configurator
Installation Fitted to one of the cable entries on the XNX transmitter. Option can be factory fitted or in the field by a qualified service engineer
Environmental Protection Port protected by cover to IP66/67 when not in use
Relay Module (Optional)
Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and
 1 x SPCO fault relay. Mutually exclusive with Modbus and/or Foundation FieldbusTM options
Rating Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Installation Option can be factory installed in display module or in the field by a qualified service engineer
XNX Stainless Steel Transmitter ATEX/IEC with MPD Catalytic Sensor 0-100%LEL
    • XNX-AMSV-NNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-NHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-RNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-RHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-MNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-MHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-AMSV-FNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD catalytic sensor 0-100%LEL.

    • XNX-AMSV-FHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD catalytic sensor 0-100%LEL
XNX Aluminum Transmitter ATEX/IEC with MPD Catalytic Sensor 0-100%LEL
    • XNX-AMAV-NNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including MPD catalytic sensor 0-100%LEL

    • XNX-AMAV-NHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-AMAV-RNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL

    • XNX-AMAV-RHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD catalytic sensor 0-100%LEL XNX-AMAV-MNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, including MPD catalytic sensor 0-100%LEL

    • XNX-AMAV-MHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD catalytic sensor 0-100%LEL.

    • XNX-AMAV-FNCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD catalytic sensor 0-100%LEL

  • XNX-AMAV-FHCB1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD catalytic sensor 0-100%LEL
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
    • XNX-AMSV-NNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL.

    • XNX-AMSV-NHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMSV-RNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMSV-RHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMSV-MNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMSV-MHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMSV-FNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR flammable sensor 0-100%LEL

  • XNX-AMSV-FHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR flammable sensor 0-100%LEL.
XNX Aluminium Transmitter ATEX/IEC with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
    • XNX-AMAV-NNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-NHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-RNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-RHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-MNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-MHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR Hydrocarbon (Propane) sensor 0-100%LEL

    • XNX-AMAV-FNIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR flammable sensor 0-100%LEL.

    • XNX-AMAV-FHIF1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR flammable sensor 0-100%LEL.
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
    • XNX-AMSV-NNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMSV-NHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).

    • XNX-AMSV-RNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMSV-RHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMSV-MNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMSV-MHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMSV-FNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V

  • XNX-AMSV-FHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR methane sensor 0-5%V/V.
XNX Aluminium Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
    • XNX-AMAV-NNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-NHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-RNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-RHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-MNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-MHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-AMAV-FNIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V

  • XNX-AMAV-FHIV1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR methane sensor 0-5%V/V
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V
    • XNX-AMSV-NNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMSV-NHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMSV-RNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V

  • XNX-AMSV-RHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR CO2 sensor 0-5%V/V
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V
    • XNX-AMSV-MNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMSV-MHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMSV-FNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR CO2 sensor 0-5%V/V

  • XNX-AMSV-FHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V
XNX Aluminium Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V
    • XNX-AMAV-NNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMAV-NHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25

    • XNX-AMAV-RNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMAV-RHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMAV-MNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMAV-MHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-AMAV-FNIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR CO2 0-5%V/V

  • XNX-AMAV-FHIC1 XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V
XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL
    • XNX-UTSV-NNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-NHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-RNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-RHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-MNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-MHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTSV-FNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD catalytic sensor 0-100%LEL

  • XNX-UTSV-FHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD catalytic sensor 0-100%LEL
XNX Aluminum Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL
    • XNX-UTAV-NNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-NHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-RNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-RHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-MNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-MHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD catalytic sensor 0-100%LEL

    • XNX-UTAV-FNCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD catalytic sensor 0-100%LEL

  • XNX-UTAV-FHCB1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD catalytic sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
    • XNX-UTSV-NNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTSV-NHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

  • XNX-UTSV-RNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
    • XNX-UTSV-RHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTSV-MNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTSV-MHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTSV-FNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR flammable sensor 0-100%LEL

  • XNX -UTSV-FHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR flammable sensor 0-100%LEL
XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
    • XNX-UTAV-NNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-NHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-RNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-RHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-MNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-MHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

    • XNX-UTAV-FNIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR flammable sensor 0-100%LEL

  • XNX-UTAV-FHIF1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR flammable sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
    • XNX-UTSV-NNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-NHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-RNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-RHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-MNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-MHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTSV-FNIV1 XNX transmitter, HART over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V

    • XNX-UTSV-FHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR methane sensor 0-5%V/V
XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)
    • XNX-UTAV-NNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, including MPD IR Methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-NHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, including MPD IR Methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-RNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-RHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR Methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-MNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-MHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)

    • XNX-UTAV-FNIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR methane sensor 0-5%V/V

  • XNX-UTAV-FHIV1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR methane sensor 0-5%V/V
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V
    • XNX-UTSV-NNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-NHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-RNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-RHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-MNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-MHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTSV-FNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, including MPD IR CO2 sensor 0-5%V/V

  • XNX-UTSV-FHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V
XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V
    • XNX-UTAV-NNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-NHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-RNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-RHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-MNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-MHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V

    • XNX-UTAV-FNIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, including MPD IR CO2 0-5%V/V

    • XNX-UTAV-FHIC1 XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, including MPD IR CO2 sensor 0-5%V/V
Spare MPD Sensors
    • MPD-AMCB1 XNX MPD Sensor, M25, ATEX/IEC approved, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

    • MPD-AMIF1 XNX MPD Sensor, M25, ATEX/IEC approved, IR Hydrocarbons (Propane Cal) 0-100%LEL

    • MPD-AMIV1 XNX MPD Sensor, M25, ATEX/IEC approved, IR Methane 0-100%LEL or 0-5.00% Vol.

    • MPD-AMIC1 XNX MPD Sensor, M25, ATEX/IEC approved, IR Carbon Dioxide 0-5.00%Vol.

    • MPD-UTCB1 XNX MPD Sensor, 3/4"NPT, UL/CSA approved, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

    • MPD-UTIF1 XNX MPD Sensor, 3/4"NPT, UL/CSA approved, IR Hydrocarbons (Propane Cal) 0-100%LEL

    • MPD-UTIV1 XNX MPD Sensor, 3/4"NPT, UL/CSA approved, IR Methane 0-100%LEL or 0-5.00% Vol.

    • MPD-UTIC1 XNX MPD Sensor, 3/4"NPT, UL/CSA approved, IR Carbon Dioxide 0-5.00%Vol.
Spare MPD Replaceable Cartridges
    • 1226A0359 XNX MPD Cartridge, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

    • 1226-0300 XNX MPD Cartridge, IR Hydrocarbons (Propane Cal) 0-100%LEL

    • 1226-0299 XNX MPD Cartridge, IR Methane 0-100%LEL or 0-5.00% Vol.

    • 1226-0301 XNX MPD Cartridge, IR Carbon Dioxide 0-5.00%Vol.
XNX Stainless Steel Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor
    • XNX-AMSV-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for mV sensors

    • XNX-AMSV-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, configured for mV sensors

    • XNX-AMSV-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for mV sensors

    • XNX-AMSV-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for mV sensors

    • XNX-AMSV-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, configured for mV sensors

    • XNX-AMSV-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for mV sensors

    • XNX-AMSV-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for mV sensors

    • XNX-AMSV-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for mV sensors
XNX Aluminum Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor
    • XNX-AMAV-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, configured for mV sensors

    • XNX-AMAV-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, configured for mV sensors

    • XNX-AMAV-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for mV sensors

    • XNX-AMAV-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for mV sensors

    • XNX-AMAV-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, configured for mV sensors

    • XNX-AMAV-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for mV sensors

    • XNX-AMAV-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for mV sensors

    • XNX-AMAV-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for mV sensors
XNX Stainless Steel Transmitter UL/CSA for use with model 705 High Temperature Sensor
    • XNX-UTSV-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for mV sensors

    • XNX-UTSV-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, configured for mV sensors

    • XNX-UTSV-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for mV sensors

    • XNX-UTSV-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for mV sensors

    • XNX-UTSV-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, configured for mV sensors

    • XNX-UTSV-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for mV sensors.

    • XNX-UTSV-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for mV sensors.

  • XNX-UTSV-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for mV sensors
XNX Aluminum Transmitter UL/CSA for use with 705 High Temperature Sensor
    • XNX-UTAV-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, configured for mV sensors

    • XNX-UTAV-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, configured for mV sensors

    • XNX-UTAV-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for mV sensors

    • XNX-UTAV-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for mV sensors

    • XNX-UTAV-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, configured for mV sensors

    • XNX-UTAV-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for mV sensors

    • XNX-UTAV-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for mV sensors

  • XNX-UTAV-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for mV sensors
XNX Stainless Steel Transmitter ATEX/IEC for use with XNX Toxic and Oxygen Sensors
    • XNX-AMSE-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for XNX toxic and Oxygen sensors

    • XNX-AMSE-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, configured for XNX toxic and Oxygen sensors

      o
    • XNX-AMSE-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for XNX toxic and Oxygen sensors

    • XNX-AMSE-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-AMSE-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, configured for XNX toxic and Oxygen sensors

    • XNX-AMSE-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for XNX toxic and Oxygen sensors.

    • XNX-AMSE-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for XNX toxic and Oxygen sensors.

  • XNX-AMSE-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for XNX toxic and Oxygen sensors
XNX Aluminium Transmitter ATEX/IEC for use with XNX Toxic and Oxygen Sensors
    • XNX-AMAE-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, configured for XNX toxic and Oxygen sensors

    • XNX-AMAE-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, configured for XNX toxic and Oxygen sensors.

    • XNX-AMAE-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for XNX toxic and Oxygen sensors

    • XNX-AMAE-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-AMAE-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, configured for XNX toxic and Oxygen sensors

    • XNX-AMAE-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-AMAE-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for XNX toxic and Oxygen sensors

  • XNX-AMAE-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for XNX toxic and Oxygen sensors.
XNX Stainless Steel Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors
    • XNX-UTSE-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for XNX toxic and Oxygen sensors

    • XNX-UTSE-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, configured for XNX toxic and Oxygen sensors.

    • XNX-UTSE-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for XNX toxic and Oxygen sensors

    • XNX-UTSE-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-UTSE-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, configured for XNX toxic and Oxygen sensors

    • XNX-UTSE-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for XNX toxic and Oxygen sensors.

    • XNX-UTSE-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for XNX toxic and Oxygen sensors.

  • XNX-UTSE-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for XNX toxic and Oxygen sensors.
XNX Aluminium Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors
    • XNX-UTAE-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, configured for XNX toxic and Oxygen sensors.

    • XNX-UTAE-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for XNX toxic and Oxygen sensors

    • XNX-UTAE-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for XNX toxic and Oxygen sensors.
XNX Toxic and Oxygen Sensors
    • XNXXSO1SS XNX sensor Oxygen 0-25%VOL

    • XNXXSC1SS XNX sensor Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm)

    • XNXXSH3SS XNX sensor Hydrogen Sulfide 0-5ppm (1.5 to 5ppm, 0.1ppm)

    • XNXXSH1SS XNX sensor Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm)

    • XNXXSH2SS XNX sensor Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm)

    • XNXXSL1SS XNX sensor Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

    • XNXXSL2SS XNX sensor Chlorine 0-5.0ppm

    • XNXXSS1SS XNX sensor Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

    • XNXXSX1SS XNX sensor Chlorine Dioxide 0-1.00ppm

    • XNXXSM1SS XNX sensor Nitrogen Monoxide 0-100ppm

    • XNXXSN1SS XNX sensor Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

    • XNXXSG1SS XNX sensor Hydrogen 0-1000ppm

    • XNXXSG2SS XNX sensor Hydrogen 0-10,000ppm

    • XNXXSR1SS XNX sensor Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

    • XNXXSA1SS XNX sensor Ammonia 0-200ppm (50 to 200ppm, 50ppm)

  • XNXXSA2SS XNX sensor Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)
XNX Toxic and Oxygen Cartridges
    • XNXO1SS XNX Cartridge Oxygen 0-25%VOL

    • XNXC1SS XNX Cartridge Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm)

    • XNXH3SS XNX Cartridge Hydrogen Sulfide 0-5ppm (1.5 to 5ppm, 0.1ppm)

    • XNXH1SS XNX Cartridge Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm)

    • XNXH2SS XNX Cartridge Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm)

    • XNXL1SS XNX Cartridge Chlorine 0-5.0ppm

    • XNXS1SS XNX Cartridge Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)

    • XNXX1SS XNX Cartridge Chlorine Dioxide 0-1.00ppm

    • XNXM1SS XNX Cartridge Nitrogen Monoxide 0-100ppm

    • XNXN1SS XNX Cartridge Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)

    • XNXG1SS XNX Cartridge Hydrogen 0-1000ppm

    • XNXG2SS XNX Cartridge Hydrogen 0-10,000ppm

    • XNXR1SS XNX Cartridge Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm)

    • XNXA1SS XNX Cartridge Ammonia 0-200ppm (50 to 200ppm, 50ppm)

    • XNXA2SS XNX Cartridge Ammonia 0-1000ppm (200 to 1000ppm, 50ppm)
XNX Stainless Steel Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors
    • XNX-AMSI-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMSI-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for Searchpoint Optima Plus and Searchline Excel

  • XNX-AMSI-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel
XNX Aluminuim Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors
    • XNX-AMAI-NNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-NHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-RNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-RHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-MNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-MHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-AMAI-FNNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for Searchpoint Optima Plus and Searchline Excel

  • XNX-AMAI-FHNNN XNX transmitter, HART over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel
XNX Stainless Steel Transmitter UL/CSA for use with Searchpoint Optima Plus and Searchline Excel Detectors
    • XNX-UTSI-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional ModBus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTSI-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output, configured for Searchpoint Optima Plus and Searchline Excel.

  • XNX-UTSI-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel.
XNX Aluminuim Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors
    • XNX-UTAI-NNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTAI-NHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTAI-RNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, configured for Searchpoint Optima Plus and Searchline Excel.

    • XNX-UTAI-RHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTAI-MNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, configured for Searchpoint Optima Plus and Searchline Excel

    • XNX-UTAI-MHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output and local HART interface port, configured for Optima Plus and Searchline Excel

    • XNX-UTAI-FNNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output, configured for Searchpoint Optima Plus and Searchline Excel

  • XNX-UTAI-FHNNN XNX transmitter, HART over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional Foundation Fieldbus output and local HART interface port, configured for Searchpoint Optima Plus and Searchline Excel
Searchline Excel Short Range 5m - 40m (15ft - 130ft)
    • 02104-N-XSAA Short range system 5m to 40m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX and junction box

    • 02104-N-XSSA Short range system 5m to 40m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX and junction box

    • 02104-N-XSAU Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box

    • 02104-N-XSSU Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box

    • 02104-N-XSAC Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box

    • 02104-N-XSSC Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box

  • 02104-N-NSNA Short range system 5m to 40m ATEX complete TXR and RXR system, SS316 mounting plates and fitting for XNX. Add XNX and Junction box as required
Searchline Excel Medium Range 40m - 120m (130ft - 390ft)
    • 02104-N-XMAA Medium range system 40m to 120m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX and junction box.

    • 02104-N-XMSA Medium range system 40m to 120m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX and junction box.

    • 02104-N-XMAU Medium range system 40m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    • 02104-N-XMSU Medium range system 40m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box

    • 02104-N-XMAC Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box

  • 02104-N-XMSC Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box
Searchline Excel Long Range 120m - 200m (390ft - 650ft)
    • 02104-N-XLAA Long range system 120m to 200m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX and junction box.

    • 02104-N-XLSA Long range system 120m to 200m ATEX complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX and junction box.

    • 02104-N-XLAU Long range system 120m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

    • 02104-N-XLSU Long range system 120m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.

    • 02104-N-XLAC Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box.

  • 02104-N-XLSC Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box.
XNX and Searchline Excel Alignment Kits
    • 02104-N-4006X Short Range Searchline Excel and XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1)

  • 02104-N-4007X Long/Medium Range Searchline Excel and XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1)
XNX Spares and Accessories
    • 1226-9001 XNX Transmitter Spare Pod, Infrared Personality, No Options

    • 1226-9002 XNX Transmitter Spare Pod, Infrared Personality, Relay Option

    • 1226-9003 XNX Transmitter Spare Pod, Infrared Personality, ModBus Options

    • 1226-9004 XNX Transmitter Spare Pod, Infrared Personality, Foundation Fieldbus Options

    • 1226-9009 XNX Transmitter Spare Pod, Millivolt Personality, No Options

    • 1226-9010 XNX Transmitter Spare Pod, Millivolt Personality, Relay Option

    • 1226-9011 XNX Transmitter Spare Pod, Millivolt Personality, ModBus Option

    • 1226-9012 XNX Transmitter Spare Pod, Millivolt Personality, Foundation Fieldbus Options

    • 1226-9005 XNX Transmitter Spare Pod, Electrochemical Personality, No Options

    • 1226-9006 XNX Transmitter Spare Pod, Electrochemical Personality, Relay Option

    • 1226-9007 XNX Transmitter Spare Pod, Electrochemical Personality, ModBus Option

    • 1226-9008 XNX Transmitter Spare Pod, Electrochemical Personality, Foundation Fieldbus Options

    • XNX-RLY Relay Option

    • XNX-MB ModBus Option

    • XNX-FB Foundation Fieldbus Option

    • 1226A0358 Pipe Mount Kit

    • S3KRMK Remote mounting kit for Series 3000 and XNX EC toxic sensors

    • 1226A0355 Ceiling Mount Bracket Kit

    • S3KDMK Duct mounting kit for Series 3000 and XNX EC toxic sensors

    • 1226A0382 MPD Interface Adaptor (for use with S3KDMK Duct Mount Kit)

    • S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors

    • 1226A0411 Calibration Gas Flow Adaptor (for use with MPD)

    • 02000-A-1645 Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

    • 00780-A-0035 Flow Housing

    • S3KWP Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic sensors

    • 02000-A-1640 Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

    • 02000-A-1635 Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

    • SPXCDCC Collecting cone for use with lighter than air gases

    • 02000-A-1642 Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)

    • 2441-0022 UL/CSA Aluminium Junction Box Assembly (for remote mount of MPD sensors)

    • 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved

    • 1226A0354 Remote Gassing Kit

    • 1226-0257 M25 Stopping Plug w/ protective cap and O-ring

    • 1226-0258 3/4" NPT Stopping Plug w/ protective cap and O-ring

    • 0235-0238 Replacement O-ring for XNX front cover

    • 1226A0302 Terminal Block Assembly 6-Pin for XNX EC

    • 1226A0304 Terminal Block Assembly 9-Pin for XNX mV

    • 1226A0305 IR Terminal Block Assembly Kit includes: 9-Pin and 2 Pin blocks

    • 1226A0306 Relay Terminal Block Assembly Kit includes: 9-Pin and 2-Pin blocks

    • 1226A0307 Terminal Block Assembly 10-Pin for XNX ModBus

    • 1226-0254 Magnetic Wand/Screwdriver

  • 1226-0408 Small Screwdriver (for use with Relay board and IR personality board)