Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
The Horiba LAQUA 200 Series is a line of advanced benchtop meters designed for precise water quality analysis. These instruments are capable of measuring various parameters, including pH, ion concentration, conductivity, and dissolved oxygen. They feature a user-friendly interface with a large LCD screen, facilitating easy data interpretation. The series supports multiple calibration points to enhance measurement accuracy and offers data logging capabilities for efficient record-keeping. Additionally, the LAQUA 200 Series is compatible with a range of electrodes and accessories, making it suitable for diverse laboratory applications.
The series includes dedicated meters for specific parameters and multiparameter models capable of measuring multiple parameters simultaneously:
|
|
Model |
LAQUA PH210 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 500 |
Auto Data Log | Yes |
Measurement Modes | Auto Stable, Auto Hold, and Real time |
Offset & Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: Up to 90 days) |
Auto Shut-Off | Yes (Programmable: Up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Meter Inputs | BNC (for pH electrode), phono (for temperature sensor) |
Display | Custom LCD with backlight |
Housing | IP67 rating, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
Model | LAQUA PH220 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Data Log | Yes |
Real-time Clock | Yes |
Date & Time Stamp | Yes |
Measurement Modes | Auto Stable, Auto Hold, and Real time |
Offset & Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: Up to 90 days) |
Auto Shut-Off | Yes (Programmable: Up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
PC Communication | Yes via PC (USB) cable PN 3200779639 |
Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
Meter Inputs | BNC (for pH electrode), phono (for temperature sensor) |
Meter Output | phono (for PC/printer connection) |
Display | Custom LCD with backlight |
Housing | IP67 rating, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
Model | LAQUA EC210 |
---|---|
Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00% (adjustable) |
Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Measurement Unit | S/cm, S/m (selectable / auto-ranging) |
TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
Accuracy | ±0.1% full scale |
TDS Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01% |
Accuracy | ±0.2% full scale |
Salinity Curves | NaCl / Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °C |
Calibration Option | Yes |
Memory Data | 500 |
Auto Log Data | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Meter Inputs | BNC (for conductivity electrode), phono (for temperature sensor) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
Model | LAQUA EC220 |
---|---|
Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00% (adjustable) |
Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Measurement Unit | S/cm, S/m (selectable / auto-ranging) |
TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
Accuracy | ±0.1% full scale |
TDS Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01% |
Accuracy | ±0.2% full scale |
Salinity Curves | NaCl / Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °C |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date & Time Stamp | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Auto-Shut Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Software Upgrade | Yes via PC (USB) cable PN 3200779639 |
PC Communication | Yes via PC (USB) cable PN 3200779639 |
Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
Meter Inputs | BNC (for conductivity electrode), phono (for temperature sensor) |
Meter Output | phono (for PC/printer connection) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
Model | LAQUA DO210 |
---|---|
DO Range |
0.0 to 20.00 mg/L 0.0 to 200.0% |
Resolution | 0.01 mg/L, 0.1% |
Accuracy | ± 0.1 mg/L |
Salinity Compensation | 0.0 to 40.0 ppt |
Barometric Pressure Compensation | Yes |
Temperature Compensation | Yes |
DO Probe Type | Galvanic integrated with temperature sensor |
Calibration Points | Up to 2 |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °C |
Calibration Option | Yes |
Memory Data | 500 |
Auto Log Data | Yes |
Measurement Modes | Auto stable, Auto hold, Real time |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Meter Inputs | BNC (for DO electrode), phono (for temperature sensor) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
Model | LAQUA DO220 |
---|---|
DO Range |
0.0 to 20.00 mg/L 0.0 to 200.0% |
Resolution | 0.01 mg/L, 0.1% |
Accuracy | ± 0.1 mg/L |
Salinity Compensation | 0.0 to 40.0 ppt |
Barometric Pressure Compensation | Yes |
Temperature Compensation | Yes |
DO Probe Type | Galvanic integrated with temperature sensor |
Calibration Points | Up to 2 |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °C |
Calibration Option | Yes |
Memory Data | 500 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date & Time Stamp | Yes |
Measurement Modes | Auto stable, Auto hold, Real time |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
PC Communication | Yes via PC (USB) cable PN 3200779639 |
Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
Meter Inputs | BNC (for DO electrode), phono (for temperature sensor) |
Meter Output | phono (for PC/printer connection) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
Model | LAQUA PC210 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST), Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00% (adjustable) |
Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Unit Setting | S/cm, S/m (Auto-ranging) |
TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
Accuracy | ±0.1% full scale |
Calibration Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
Salinity Range |
0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01 % |
Accuracy | ±0.2% full scale |
Calibration Curves | NaCl, Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 500 |
Auto Log Data | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Offset / Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: up to 90 days) |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Meter Inputs | 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
Model | LAQUA PC220 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST), Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15 to 30 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00% (adjustable) |
Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Unit Setting | S/cm, S/m (Auto-ranging) |
TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
Accuracy | ±0.1% full scale |
Calibration Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.05% full scale |
Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
Salinity Range |
0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01 % |
Accuracy | ±0.2% full scale |
Calibration Curves | NaCl, Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date & Time Stamp | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Offset / Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: up to 90 days) |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
PC Communication | Yes via PC (USB) cable PN 3200779639 |
Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
Meter Inputs | 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) |
Meter Output | phono (for PC/printer connection) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
Model | LAQUA PD210 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
DO Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % |
Resolution | 0.01 mg/L or 0.1 % |
Accuracy | ±0.1 mg/L |
Salinity Compensation | 0.0 to 40.0 ppt |
Barometric Pressure Compensation | Yes |
Temperature Compensation | Yes |
Calibration Points | Up to 2 |
DO Probe Type | Galvanic integrated with temperature sensor |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 500 |
Auto Log Data | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Offset & Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: up to 90 days) |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
Meter Inputs | 2 x BNC (for pH and DO electrodes), 2 x phono (for temperature sensors) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
Model | LAQUA PD220 |
---|---|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
Buffer Options | USA, NIST, DIN |
ORP Range | ± 2000 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
Calibration Option | Yes |
DO Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % |
Resolution | 0.01 mg/L or 0.1 % |
Accuracy | ±0.1 mg/L |
Salinity Compensation | 0.0 to 40.0 ppt |
Barometric Pressure Compensation | Yes |
Temperature Compensation | Yes |
Calibration Points | Up to 2 |
DO Probe Type | Galvanic integrated with temperature sensor |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes |
Memory Data | 1000 |
Auto Log Data | Yes |
Real-time Clock | Yes |
Date & Time Stamp | Yes |
Measurement Modes | Auto Stable, Auto Hold, Real Time |
Offset & Average Slope Display | Yes |
Calibration Alarm | Yes (Programmable: up to 90 days) |
Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
Electrode Status | Yes (On screen display) |
Diagnostic Messages | Yes |
PC Communication | Yes via PC (USB) cable PN 3200779639 |
Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
Meter Inputs | 2 x BNC (for pH and DO electrodes), 2 x phono (for temperature sensors) |
Meter Output | phono (for PC/printer connection) |
Display | Custom LCD with backlight |
Housing | IP67, shock & scratch resistant, non-slip |
Power Requirement | 2 x AA batteries |
Battery Life | > 500 hours |
Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
By submitting your details you consent to their use in accordance with our Privacy Notice