Product Features
  • Measurement Parameters: pH, ORP, ion, conductivity, resistivity, TDS, salinity, temperature
  • Calibration: Up to 6 points, USA/NIST/DIN/custom buffer groups
  • Data Storage: 2,000 sets, auto-logging with timestamps
  • Display: 5” custom LCD with backlight
  • Connectivity: USB for PC, RS232C for printer, data software support
  • Advanced Functions: Real-time clock, auto shut-off, password protection, calibration alarms, electrode status, software upgrades
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Horiba Laqua 2000 Series Custom LCD Bench Meters

SKU
Horiba-LAQUA-2000-Series-LCD-Bench-Meters

Horiba Laqua Bench Meters

2000 Series Custom LCD Bench Meters

 

Horiba's LAQUA 2000 Series comprises benchtop meters designed for accurate water quality analysis, featuring a 5-inch custom LCD with backlight for clear data visualisation.

 

 

 

 

LAQUA PH2000

LAQUA ION2000

LAQUA EC2000

LAQUA DO2000

LAQUA PC2000

LAQUA PD2000

 

 

Model LAQUA-PH2000
pH/ORP/Temp (°C/°F) Bench Meter
pH Range -2.000 to 20.000 pH
Resolution 0.1 / 0.01 / 0.001 pH
Accuracy ± 0.003 pH 
pH Buffer Groups USA, NIST, NIST2, DIN, Custom
Calibration Points Up to 5 (USA, NIST, NIST2) / Up to 6 (DIN, Custom)
ORP Range ± 2000.0 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV
Calibration Option Yes (Up to ± 200 mV)
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes  Auto Stable / Auto Hold  / Real Time
Offset & Slope Display Yes (Segment & Average Slopes)
Calibration Alarm  Yes (Programmable: up to 90 days)
Auto Shut-Off  Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs BNC, phono (ATC), DC sockets
Display 5" Custom LCD with backlight and 320 segments
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 765g

 

Model LAQUA-ION2000
pH/ORP/Ion/Temp (°C/°F) Bench Meter
pH Range -2.000 to 20.000 pH
Resolution 0.1 / 0.01 / 0.001 pH
Accuracy ± 0.003 pH 
pH Buffer Groups USA, NIST, NIST2, DIN, Custom
Calibration Points Up to 5 (USA, NIST, NIST2,Custom) / Up to 6 (DIN,)
ORP Range ± 2000.0 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV
Calibration Option Yes (Up to ± 200 mV)
Ion Range 0.000 µg/L to 9999 g/L
Units  µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
Resolution 4 Significant digits
Accuracy ± 0.3% full scale or ± 0.2 mV, whichever is higher
Calibration Points Up to 5 
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes  Auto Stable / Auto Hold  / Real Time
Offset & Slope Display Yes (Segment & Average Slopes)
Calibration Alarm  Yes (Programmable: up to 90 days)
Auto Shut-Off  Yes (programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs BNC, phono (ATC), DC sockets
Display 5" Custom LCD with backlight and 320 segments
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 765g

 

Model LAQUA-EC2000
Conductivity/Resistivity/TDS/Salinity/Temp (°C/°F) Bench Meter
Conductivity Range 0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
Units Auto ranging S/cm, S/m (µS ↔ mS ↔ S)
Resolution 0.05% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm
Reference Temperature 15.0 to 30.0 °C (adjustable)
Temperature Coefficient 0.00 to 10.00 % per °C (adjustable)
Cell Constants 0.070 to 13.00 (adjustable)
Calibration Points Up to 4 (Auto) / Up to 5 (Manual)
Resistivity Range 0.001 MΩ・cm to 20.0 MΩ・cm
Resolution 0.5% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ・cm
Total Dissolved Solids (TDS) Range 0.01 to 9.99 mg/L (ppm)
10.0 to 99.9 mg/L (ppm)
100 to 999 mg/L (ppm)
1.00 to 9.99 g/L (ppt)
10.0 to 100 g/L (ppt)
Resolution 0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)
Accuracy ± 0.1% full scale
TDS Curves EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 %
Resolution 0.1 ppt / 0.01%
Accuracy ± 0.2% full scale
Salinity Curves NaCl / Seawater
Calibration Option Yes (Manual; 1 point)
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable / Auto Hold / Real Time
Auto Shut-Off  Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs BNC, phono, DC sockets
Display 5" Custom LCD with backlight and 320 segments
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 765g

 

Model

LAQUA-DO2000

DO/BOD/Temperature (°C/°F)

DO Range 0.0 to 60.00 mg/L, 0.0 to 600.0%
Resolution 0.01 mg/L, 0.1%
Accuracy +/- 0.1 mg/L , +/- 1.0%
Salinity Compensation 0.0 to 40.0 ppt
Barometric Pressure Compensation 10.0 to 200.0 kPa
BOD Measurement 5-day BOD with seed correction option
DO Probe Type Galvanic integrated with temperature sensor
Calibration Points Up to 2
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable / Auto Hold / Real Time
Auto Shut-Off  Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs BNC, phono (ATC), DC sockets
Display 5" Custom LCD with 320 segments and backlight
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 765g

 

Model LAQUA-PC2000
 pH/ORP/Ion/Conductivity/Resistivity/TDS/Salinity/Temp (°C/°F)
pH Range -2.000 to 20.000 pH
Resolution 0.1 / 0.01 / 0.001 pH
Accuracy ± 0.003 pH
pH Buffer Groups USA, NIST, NIST2, DIN, Custom
Calibration Points Up to 5 (USA, NIST, NIST2, Custom) / Up to 6 (DIN)
ORP Range ± 2000.0 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV 
Calibration Option Yes (Up to ± 200 mV)
Ion Range 0.000 µg/L to 9999 g/L
Units  µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
Resolution 4 Significant digits
Accuracy ± 0.3% full scale or ± 0.2 mV, whichever is higher
Calibration Points Up to 5 
Conductivity Range 0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
Units Auto ranging S/cm, S/m (µS ↔ mS ↔ S)
Resolution 0.05% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm
Reference Temperature 15.0 to 30.0 °C (adjustable)
Temperature Coefficient 0.00 to 10.00 % per °C (adjustable)
Cell Constants 0.070 to 13.00 (adjustable)
Calibration Points Up to 4 (Auto) / Up to 5 (Manual)
Resistivity Range 0.001 MΩ・cm to 20.0 MΩ・cm
Resolution 0.5% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ●cm
Total Dissolved Solids (TDS) Range 0.01 to 9.99 mg/L (ppm)
10.0 to 99.9 mg/L (ppm)
100 to 999 mg/L (ppm)
1.00 to 9.99 g/L (ppt)
10.0 to 100 g/L (ppt)
Resolution 0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)
Accuracy ± 0.1% full scale
TDS Curves EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 %
Resolution 0.1 ppt / 0.01%
Accuracy ± 0.2% full scale
Salinity Curves NaCl / Seawater
Calibration Option Yes (Manual; 1 point)
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable / Auto Hold / Real Time
Offset & Slope Display Yes (Segment & Average Slopes)
Calibration Alarm  Yes (Programmable: up to 90 days)
Auto Shut-Off  Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs 2 x BNC, 2 x phono (ATC), DC sockets
Display 5" Custom LCD with backlight and 320 segments
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 770g

 

Model

LAQUA-PD2000 

pH/ORP/Ion/DO/BOD/Temperature (°C/°F)

pH Range -2.000 to 20.000 pH
Resolution 0.1 / 0.01 / 0.001 pH
Accuracy ± 0.003 pH
pH Buffer Groups USA, NIST, NIST2, DIN, Custom
Calibration Points Up to 5 (USA, NIST, NIST2) / Up to 6 (DIN, Custom)
ORP Range ± 2000.0 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV 
Calibration Option Yes (Up to ± 200 mV)
Ion Range 0.000 µg/L to 9999 g/L
Units  µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
Resolution 4 Significant digits
Accuracy ± 0.3% full scale or ± 0.2 mV, whichever is higher
Calibration Points Up to 5 
DO Range 0.0 to 60.00 mg/L, 0.0 to 600.0%
Resolution 0.01 mg/L, 0.1%
Accuracy +/- 0.1 mg/L , +/- 1.0%
Salinity Compensation 0.0 to 40.0 ppt
Barometric Pressure Compensation 10.0 to 200.0 kPa
BOD Measurement 5-day BOD with seed correction option
DO Probe Type Galvanic integrated with temperature sensor
Calibration Points Up to 2
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable / Auto Hold / Real Time
Offset & Slope Display Yes (Segment & Average Slopes)
Calibration Alarm  Yes (Programmable: up to 90 days)
Auto Shut-Off  Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs 2 x BNC, 2 x phono (ATC), DC sockets
Display 5" Custom LCD with 320 segments and backlight
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 770g

 

Write Your Own Review