Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
The FREEDOM Xi is ideally suited for:
A detection technology for every risk
Because every site presents unique challenges, the FREEDOM Xi offers a wide range of detection technologies suited to specific hazards and environmental conditions.
Whether monitoring toxic gases, oxygen depletion or enrichment, CO₂, or refrigerants, the FREEDOM Xi provides the most appropriate sensing technology: electrochemical or Rock Solid cells, infrared or semiconductor sensors. Each sensing cartridge is pre-calibrated for fast, tool-free commissioning and optimum accuracy from day one.
This modular approach enables the FREEDOM Xi to adapt to virtually any industrial environment. The FREEDOM Xi features a single universal mainboard compatible with all detection technologies and gas types.

A clear and intuitive user interface
The FREEDOM Xi’s interface is designed for intuitive operation with no need for specialised tools or complex procedures. Its multicolour TFT display provides comprehensive information at a glance, including real-time readings, detected gas, measurement units, live trend graphs and text-based configuration menus.
Smooth navigation across the menus is achieved using four magnet-activated buttons, eliminating the need to open the housing in hazardous areas.
Peripheral LEDs surrounding the display provide clear, long-distance visibility of the FREEDOM Xi’s status and interactions, even in bright ambient light.
At a glance, operators can identify whether the unit is operating normally, in fault or alarm condition, or connected via Bluetooth to the GF Sync app.
Overall, the interface is designed to simplify operations and enhance user confidence in the field.
A display designed for harsh environments
In extreme temperatures, the optional LCD enables operation across a wide temperature range, from -40°C to +75°C.
An exclusive hot-swap function for uninterrupted continuity
The hot-swap functionality, unique on the market, enables the replacement of the sensing cartridge (for toxic and flammable gas detection) while the device remains powered, without affecting the FREEDOM certification for hazardous areas.
In critical environments, every minute matters. This unique capability ensures complete operational continuity, even during maintenance activities.
Remote sensor head and dual detection
With its remote sensor head and Dual Detection capability, the FREEDOM Xi adapts to the constraints of any industrial site. The remote sensor head allows the sensing element to be installed up to 30 metres (100 ft) from the transmitter.

The Dual Detection function enables two measurement points to be monitored using a single device. Less equipment. Less cabling. Greater flexibility. A solution designed to optimise installation while maintaining the highest level of performance.
A modular design to suit every need
Because every industrial environment has its own specific constraints, the FREEDOM Xi offers a wide range of options to tailor detection to any configuration. This flexibility ensures seamless integration into all existing systems, whether simple or complex.


Choose, Configure and Customise
This modularity makes the FREEDOM Xi a universal solution, adaptable to any architecture, any industry and any security requirement.
GF SYNC: the App that makes detection easier
Available FREE on the App Store and Google Play, the GF Sync app revolutionises gas detector management by providing instant access to all essential functions, while unlocking the full capabilities of the FREEDOM Xi:

With GF Sync, deployment and operation become faster, safer and more efficient. Your safety, at your fingertips.
We're happy to help! Please submit via the 'send enquiry' button at the top of the page to place an order, or email [email protected] or call +44 330 088 0595, and a member of the team will get back to you.
| Environmental | |
| Operating Temperature | -40° to 167°F ( -40° to +75°c) LCD Display -4° to 131°F ( -30° to +55°c) TFT Display |
| Operating humidity | 0-99 % RH (non-condensing) |
| Storage conditions | -4° to 104° F (-20° to +40°c ), 20-80 % RH (non-condensing) |
| Physical Specification | |
| Material | Copper-free aluminium or Stainless Steel 316L |
| Weight | Aluminium: 10,58 lbs (4,8 Kg), Spacer version: 11,13 lbs (5,05 Kg) (With Cartridge) Stainless steel: 13,23 lbs (6,8 Kg), Spacer version: 16,58 lbs (7,52 Kg) (With Cartridge) |
| Dimension | Standard: 9,25 x 6,46 x 5,98 ‘‘ (235 x 164 x 152 mm) Spacer version: 9,25 x 6,46 x 6,89 ‘‘ (235 x 164 x 175 mm) (With relays option) |
| Enclosure Ingress Protection | NEMA 4, IP 66 |
| Cable Entries | 4 conduit/cable entries, ¾ inch NPT or M20 |
| Electrical Specification | |
| Wiring | 2 or 3 wires, 18 to 12 AWG 0,9 to 2,5 mm2) |
| Operating Voltage | 24 VDC nominal, 2-wire 17,8 / 31,5 VDC, 3-wire 10 /31,8 VDC |
| Power consumption | Transmitter: 35 W (3 wires), 1W (2wires) Catalytic: 0,8 W, Infrared: 1 W, MEMS: 1 W, Electrochemical Cell: 0,1 W, Semiconductor 0.6 W, MOS 0,6 W Additional optional Relays: x W, Additional heating option: x W |
| Load impedance source | 2 wires: 250 Ohm max, 3 wires: 500 Ohm max, non-isolated current source |
| Output | |
| Analog | Measuring range: 4- 20 mA, source Discrete 0 to 4 mA configurable setting (fault, inhibit, maintenance call …) Isolated 4-20 mA outputs, Configurable Source or Sink mode (Optional) |
| Digital | HART™ Version 7 (3 wires only), RS485 Modbus RTU (Optional) |
| Relays (Optional) | 3 user-configurable alarm relays SPDT 4 A/24 VDC, 4 A/230 VAC 1 fault relay SPDT 4 A/24 VDC, 4 A/230 VAC Max cable size: 12 AWG, 2.5 mm2 |
| User Interface | |
| Display | TFT or LCD display Main screen: Gas reading, label, zone, gas name, measurement unit Intuitive automatic calibration procedure Multi-language: English, Spanish, French 2-level passwords, event data logging TFT: Graphical multicolour high resolution, display size 1,65 x 1,25 inch (42 x 32 mm) Trend Graph with selectable time scale showing current reading and alarm LCD: Custom segmented LCD, 8 digits, display size 1.92 × 1.14 in (49 × 29 mm) Version without display |
| LED | Peripheral multicolour LED (Normal operation, Alarm, default, Inhibition, Calibration, Bluetooth communication) Status icons LED (Normal operation, Alarm, default, Bluetooth) |
| Alarms | 3 programmable alarms with set and reset |
| Memory | Non-volatile memory ensures configuration parameters are retained in the event of power loss |
| Magnetic Switch | 4 capacitive keys activatable with magnetic switch for menu navigation and acknowledgement and validation operations |
| Wireless Bluetooth Communication | |
| Version | Bluetooth BLE 5, point-to-point mode Option disable |
| Approval | Encryption: AES-128, registered SIG, Cyber STD conception |
| App | Teledyne GF Sync® - Free, available on the App Store and Google App |
| Distance | Up to 49 ft (15 m) |
| Functionality | Real-time reading, status, event history Full detector setup (range, alarm, calibration, relays, optional parameters) Calibration operation & report editing |
| Certification | |
| Hazardous Area | ATEX II 2(1) GD, Ex db ia [ia Ga] IIC T4..T6 Gb / Ex tb ia [ia Da] IIIC T135°C..T85°C Db IECEX, Ex db ia [ia Ga] IIC T4..T6 Gb / Ex tb ia [ia Da] IIIC T135°C..T85°C Db FM (Pending) |
| Metrologic Performance | Flammable IEC 60079-29-1 (Pending) H2S IEC62990-1 (Pending) |
| Cybersecurity | Certified Cyber Resilience Act IEC 62443-4-2 (SL1) |
| Functional safety | SIL 2 / SC3 High Demand (TÜV Pending) |
| Warranty | |
| Transmitter | 2-years |
| Sensor | Catalytic Bead sensor: 2 years Infrared sensor: CO2 3 years, refrigerant: 2 years MEMS sensor: 2 years Electrochemical sensor: cell-dependent Rock Solid: 1 year Semiconductor sensor: 1 year Metal Oxide Semiconductor sensor: 2 years |
| Hub | |
| Weight | Aluminium 17.0 lbs (7,7 Kg) |
| Dimension | 15,75 x 6,46 x 6,89‘‘ (400 x 164 x 175 mm) |
| Enclosure Ingress Protection | NEMA 4, IP 66 |
| Remote Cartridge | |
| Distance | Remote until 98 ft (30 m), cable |
| Weight | Aluminium 4.37 lbs (1,98 Kg), Stainless Steel 7,52 lbs (3,41 Kg) (with cartridge) |
| Dimension | 7,44 x 5,43 x 3,31‘‘ (189 x 138 x 84 mm) |
| Enclosure Ingress Protection | NEMA 4, IP 66 |
| Cable Entries | 2 conduit/cable entries, ¾ inch NPT or M20 |
| Hazardous Area | ATEX II 2 GD, Ex db ia IIC T4..T6 Gb / Ex tb ia IIIC T135°C..T85°C Db ATEX II 1 GD, Ex ia IIC T5 Ga / Ex ia IIIC T100°C Da IECEX, Ex db ia IIC T4..T6 Gb / Ex tb ia IIIC T135°C..T85°C Db IECEX, Ex ia IIC T5 Ga / Ex ia IIIC T100°C Da FM (Pending) |
| Sensor Specification | |
| Universal Detector cartridge | Detector head accepts all sensor types |
| Sensor Types | Combustible: Catalytic Bead, MEMS and Infrared Toxic & Oxygen: Electrochemical and Rock Solid Refrigerant gas: Infrared and Semiconductor CO2: Infrared H2S: Metal Oxide Semiconductor (MOS) |
| Hotswap | Swappable cartridge under power and certified for hazardous areas |
| Gas Name | Measuring Range | Gas Code Teledyne | Detection Technology | Techno Code Teledyne | Temperature Range | Humidity Range | Accuracy | Response Time T90 | Average life expectancy | ||||||||||||||
| °F / °C | % RH | s | Month | ||||||||||||||||||||
| C3H8 | Propane | 0- 100% LEL | 005 | Catalytic | AP (CAT16) | -40°C to 50°C | 0 to 90 | 41 | >60 months | ||||||||||||||
| C4H10 | n-butane | 0- 100% LEL | 004 | Catalytic | AP (CAT16) | -40°C to 50°C | 0 to 90 | 51 | >60 months | ||||||||||||||
| CH4 | Methane | 0- 100% LEL | 002 | Catalytic | AP (CAT16) | -40°C to 50°C | 0 to 90 | 25 | >60 months | ||||||||||||||
| H2 | Hydrogène | 0-100 %LEL | 003 | Catalytic | AP (CAT16) | -40°C to 50°C | 0 to 90 | 12 | >60 months | ||||||||||||||
| C5H12 | Pentane | 0- 100% LEL | 051 | Catalytic | AP (CAT16) | -40°C to 50°C | 0 to 90 | 80 | >60 months | ||||||||||||||
| C3H8 | Propane | 0- 100% LEL | 005 | Catalytic | CB (VQ3) | -40°C to 75°C | 0 to 95 | +/-1%LEL | 27 | >36 months | |||||||||||||
| C4H10 | Butane | 0- 100% LEL | 004 | Catalytic | CB (VQ3) | -40°C to 75°C | 0 to 95 | +/-2% LEL | 30 | >36 months | |||||||||||||
| CH4 | Méthane | 0-100 %LEL | 002 | Catalytic | CB (VQ3) | -40°C to 75°C | 0 to 95 | +/-1%LEL | 20 | >36 months | |||||||||||||
| H2 | Hydrogène | 0-100 %LEL | 003 | Catalytic | CB (VQ3) | -40°C to 75°C | 0 to 95 | +/-4%LEL | 11 | >36 months | |||||||||||||
| C5H12 | Pentane | 0- 100% LEL | 051 | Catalytic | CB (VQ3) | -40°C to 75°C | 0 to 95 | 43 | >36 months | ||||||||||||||
| Cl2 | Chlore | 0-10 ppm | 224 | Electrochem | EC | -20°C to 40°C | 15 to 90 | 55 | >24 months | ||||||||||||||
| CO | Monoxyde de carbone | 0-100 ppm | 203 | Electrochem | EC | -30°C to 50°C | 15 to 90 | +/-2% | 24 | >48 months | |||||||||||||
| CO | Monoxyde de carbone | 0-1000 ppm | 205 | Electrochem | EC | -30°C to 50°C | 15 to 90 | +/-2% | 24 | >48 months | |||||||||||||
| CO | Monoxyde de carbone | 0-300 ppm | 204 | Electrochem | EC | -30°C to 50°C | 15 to 90 | +/-2% | 24 | >48 months | |||||||||||||
| CO | Monoxyde de carbone | 0-2000 ppm | 266 | Electrochem | EC | -30°C to 50°C | 15 to 90 | +/-2% | 24 | >48 months | |||||||||||||
| H2S | Hydrogène sulfuré | 0-30 ppm | 213 | Electrochem | EC | -30°C to 50°C | 15 to 90 | 27 | >48 months | ||||||||||||||
| H2S | Hydrogène sulfuré | 0-100 ppm | 214 | Electrochem | EC | -30°C to 50°C | 15 to 90 | 27 | >48 months | ||||||||||||||
| NH3 | Ammoniac | 0-1000 ppm | 232 | Electrochem | EC | -40°C to 50°C | 15 to 90 | 44 | >24 months | ||||||||||||||
| NH3 | Ammoniac | 0-1000 ppm | 265 | Electrochem | EC | -40°C to 50°C | 15 to 90 | 44 | >24 months | ||||||||||||||
| O2 | Oxygène | 0-30 %vol | 272 | Electrochem | EC | -40°C to 60°C | 15 to 90 | 20 | >60 months | ||||||||||||||
| O3 | Ozone | 0-1 ppm | 284 | Electrochem | EC | -20°C to 40°C | 15 to 90 | 41 | >18 months | ||||||||||||||
| NH3 | Ammoniac | 0-300 ppm | 273 | Electrochem | EC | -40°C to 50°C | 15 to 90 | 44 | >24 months | ||||||||||||||
| NO | Monoxyde d'azote | 0-100 ppm | 216 | Electrochem | EC | -30°C to 50°C | 15 to 90 | +/-5% | 24 | >12 months | |||||||||||||
| NO2 | Dioxyde d'azote | 0-10 ppm | 219 | Electrochem | EC | -30°C to 50°C | 15 to 90 | 41 | >24 months | ||||||||||||||
| NO2 | Dioxyde d'azote | 0-100 ppm | 287 | Electrochem | EC | -30°C to 50°C | 15 to 90 | 41 | >24 months | ||||||||||||||
| C2H4O | Oxyde d'éthylène | 0-30 ppm | 244 | Electrochem | EC | -20°C to 50°C | 15 to 90 | 150 | >24 months | ||||||||||||||
| O2 | Oxygène | 0-10 %vol | 282 | Electrochem | EC | -40°C to 60°C | 15 to 90 | 20 | >60 months | ||||||||||||||
| Base - A B C - D E F GH IJK L M | |
| A = Enclosure material & cable entries | |
| 3 | Aluminium, M20 |
| 4 | Aluminium, 3/4NPT |
| 5 | Stainless Steel, M20 |
| 6 | Stainless Steel, 3/4NPT |
| B = Extension | |
| 0 | None |
| 2 | with aluminium spacer |
| 3 | with Stainless Steel Spacer |
| A | HUB - Double head |
| B | HUB - Double head + with aluminium spacer |
| C = Head option | |
| 1 | Local Cartridge |
| 3 | Remote Cartridge, Aluminium, M20 |
| 4 | Remote Cartridge, Aluminium, 3/4NPT |
| 5 | Remote Cartridge, Stainless Steel, M20 |
| 6 | Remote Cartridge, Stainless Steel, 3/4NPT |
| 7 | Remote Cartridge, Stainless Steel, M20, Zone 0 |
| 8 | Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0 |
| C | Input External (no cartridge) |
| D | HUB with 2 On-board cartridges |
| E | HUB with 1 On-board cartridge and 1 remote cartridge |
| F | HUB with 2 remote cartridges |
| D = Display, wires | |
| A | 3 Wires, LCD + HART |
| B | 3 Wires, TFT + HART |
| C | 3 Wires, Blind + HART |
| D | 2 Wires, LCD |
| E | 2 Wires, Blind |
| E = Output option | |
| 0 | None |
| 1 | 2nd 4-20mA output |
| F = Relays, I/O board | |
| 0 | None |
| 1 | Relays <35V, +24V Out, Ack |
| 2 | 4/20mA or GD10P Entry |
| 3 | Relays >35V, 4/20mA or GD10P Entry |
| 7 | Relays >35V, +24V Out, Ack |
| 8 | Relays >35V, +24V Out, Ack, 4/20mA or GD10P Entry |
| GH = Cell technology | |
| 00 | None |
| AP | Catalytic bead poison-resistant (Sinter) |
| CB | Catalytic bead (Sinter) |
| EC | Echem (grid) |
| EF | Echem (Sinter) |
| IF | Infrared (Sinter) |
| MO | MOS (Sinter) |
| RS | Rock Solid (Grid) |
| IJK = Gas and range | |
| 000 | None |
| Catalytic bead poison-resistant with sinter (AP) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| IJK = Gas and range | |
| 003 | H2, Hydrogen 100% LEL |
| Catalytic bead with sinter (CB) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| 003 | H2, Hydrogen 100% LEL |
| Electrochemical with grid (EC) | |
| 224 | Cl2, Chlorine, 0-10 ppm |
| 203 | CO, Carbon monoxide, 0-100 ppm |
| 204 | CO, Carbon monoxide, 0-300 ppm |
| 205 | CO, Carbon monoxide, 0-1000 ppm |
| 266 | CO, Carbon monoxide, 0-2000 ppm |
| 289 | CO/H2nul, Carbon monoxide, 0-1000 ppm |
| 244 | C2H4O, Ethylene oxide, 0-30 ppm |
| 213 | H2S, Hydrogen sulfide, 0-30 ppm |
| 214 | H2S, Hydrogen sulfide, 0-100 ppm |
| 215 | H2S, Hydrogen sulfide, 0-1000 ppm |
| 311 | H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C) |
| 231 | NH3, Ammonia, 0-100 ppm |
| 232 | NH3, Ammonia, 0-1000 ppm |
| 216 | NO, Nitric oxide, 0-100 ppm |
| 219 | NO2, Nitrogen dioxide, 0-10 ppm |
| 220 | NO2, Nitrogen dioxide, 0-30 ppm |
| 287 | NO2, Nitrogen dioxide, 0-100 ppm |
| 272 | O2, Oxygen, 0-30% Vol. |
| 284 | O3, Ozone, 0-1 ppm |
| Electrochemical with sinter (EF) | |
| 203 | CO, Carbon monoxide 0-100 ppm |
| 204 | CO, Carbon monoxide 0-300 ppm |
| 205 | CO, Carbon monoxide 0-1000 ppm |
| 266 | CO, Carbon monoxide 0-2000 ppm |
| 289 | CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm |
| 213 | H2S, Hydrogen sulfide 0-30 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| 231 | NH3, Ammonia 0-100 ppm |
| 232 | NH3, Ammonia 0-1000 ppm |
| 272 | O2, Oxygen 0-30% Vol. |
| Infrared with sinter (IF) | |
| 239 | CO2, Carbon dioxide, 0-5% Vol. |
| 526 | HFO-1234yf, 0-2,000 ppm |
| 533 | HFO-1234ze, 0-2000 ppm |
| 502 | R134A, 0-2,000 ppm |
| MOS with sinter (MO) | |
| 275 | H2S, Hydrogen sulfide 0-50 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| Rock Solid with grid (RS) | |
| 301 | Cl2, Chlorine, 0-5 ppm (low HR) |
| 284 | O3, Ozone, 0-1 ppm |
| L = Head Option | |
| 0 | None |
| A | Standard |
| B | Heating |
| M = Custom configuration | |
| 0 | None |
| C | Custom |
HUB - To be quoted if FREEDOM XI is fitted with a HUB
| Base - A BC - DEF G H - IJK LMN O P | |
| A = Head 1 Option | |
| 1 | Local Cartridge |
| 3 | Remote Cartridge, Aluminium, M20 |
| 4 | Remote Cartridge, Aluminium, 3/4NPT |
| 5 | Remote Cartridge, Stainless Steel, M20 |
| 6 | Remote Cartridge, Stainless Steel, 3/4NPT |
| 7 | Remote Cartridge, Stainless Steel, M20, Zone 0 |
| 8 | Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0 |
| BC = Cell technology | |
| 00 | None |
| AP | Catalytic bead poison resistant (Sinter) |
| CB | Catalytic bead (Sinter) |
| EC | Echem (grid) |
| EF | Echem (Sinter) |
| IF | Infrared (Sinter) |
| MO | MOS (Sinter) |
| RS | Rock Solid (Grid) |
| DEF = Gas and range | |
| 000 | None |
| Catalytic bead poison resistant with sinter (AP) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| 003 | H2, Hydrogen 100% LEL |
| Catalytic bead with sinter (CB) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| 003 | H2, Hydrogen 100% LEL |
| Electrochemical with grid (EC) | |
| 224 | Cl2, Chlorine, 0-10 ppm |
| 203 | CO, Carbon monoxide, 0-100 ppm |
| 204 | CO, Carbon monoxide, 0-300 ppm |
| 205 | CO, Carbon monoxide, 0-1000 ppm |
| 266 | CO, Carbon monoxide, 0-2000 ppm |
| 289 | CO/H2nul, Carbon monoxide, 0-1000 ppm |
| 244 | C2H4O, Ethylene oxide, 0-30 ppm |
| 213 | H2S, Hydrogen sulfide, 0-30 ppm |
| 214 | H2S, Hydrogen sulfide, 0-100 ppm |
| 215 | H2S, Hydrogen sulfide, 0-1000 ppm |
| 311 | H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C) |
| 231 | NH3, Ammonia, 0-100 ppm |
| 232 | NH3, Ammonia, 0-1000 ppm |
| 216 | NO, Nitric oxide, 0-100 ppm |
| 219 | NO2, Nitrogen dioxide, 0-10 ppm |
| 220 | NO2, Nitrogen dioxide, 0-30 ppm |
| 287 | NO2, Nitrogen dioxide, 0-100 ppm |
| 272 | O2, Oxygen, 0-30% Vol. |
| 284 | O3, Ozone, 0-1 ppm |
| Electrochemical with sinter (EF) | |
| 203 | CO, Carbon monoxide 0-100 ppm |
| 204 | CO, Carbon monoxide 0-300 ppm |
| 205 | CO, Carbon monoxide 0-1000 ppm |
| 266 | CO, Carbon monoxide 0-2000 ppm |
| 289 | CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm |
| 213 | H2S, Hydrogen sulfide 0-30 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| 231 | NH3, Ammonia 0-100 ppm |
| 232 | NH3, Ammonia 0-1000 ppm |
| 272 | O2, Oxygen 0-30% Vol. |
| Infrared with sinter (IF) | |
| 239 | CO2, Carbon dioxide, 0-5% Vol. no charge |
| 526 | HFO-1234yf, 0-2,000 ppm |
| 533 | HFO-1234ze, 0-2000 ppm |
| 502 | R134A, 0-2,000 ppm |
| MOS with sinter (MO) | |
| 275 | H2S, Hydrogen sulfide 0-50 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| Rock Solid with grid (RS) | |
| 301 | Cl2, Chlorine, 0-5 ppm (low HR) |
| 284 | O3, Ozone, 0-1 ppm |
| G = Head Option | |
| 0 | None |
| A | Standard |
| B | Heating |
| H = Custom configuration | |
| 0 | None |
| C | Custom |
| I = Head 2 Option | |
| 1 | Local Cartridge |
| 3 | Remote Cartridge, Aluminium, M20 |
| 4 | Remote Cartridge, Aluminium, 3/4NPT |
| 5 | Remote Cartridge, Stainless Steel, M20 |
| 6 | Remote Cartridge, Stainless Steel, 3/4NPT |
| 7 | Remote Cartridge, Stainless Steel, M20, Zone 0 |
| 8 | Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0 £ |
| JK = Cell technology | |
| 00 | None |
| AP | Catalytic bead poison resistant (Sinter) |
| CB | Catalytic bead (Sinter) |
| EC | Echem (grid) |
| EF | Echem (Sinter) |
| IF | Infrared (Sinter) |
| MO | MOS (Sinter) |
| RS | Rock Solid (Grid) |
| LMN = Gas and range | |
| 000 | None |
| Catalytic bead poison resistant with sinter (AP) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| 003 | H2, Hydrogen 100% LEL |
| Catalytic bead with sinter (CB) | |
| 002 | CH4, Methane 100% LEL |
| 005 | C3H8, Propane 100% LEL |
| 004 | C4H10, Butane 100% LEL |
| 051 | C5H12, Pentane 100% LEL |
| 003 | H2, Hydrogen 100% LEL |
| Electrochemical with grid (EC) | |
| 224 | Cl2, Chlorine, 0-10 ppm |
| 203 | CO, Carbon monoxide, 0-100 ppm |
| 204 | CO, Carbon monoxide, 0-300 ppm |
| 205 | CO, Carbon monoxide, 0-1000 ppm |
| 266 | CO, Carbon monoxide, 0-2000 ppm |
| LMN = Gas and range | |
| Electrochemical with grid (EC) | |
| 289 | CO/H2nul, Carbon monoxide, 0-1000 ppm |
| 213 | H2S, Hydrogen sulfide, 0-30 ppm |
| 214 | H2S, Hydrogen sulfide, 0-100 ppm |
| 311 | H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C) |
| 231 | NH3, Ammonia, 0-100 ppm |
| 232 | NH3, Ammonia, 0-1000 ppm |
| 216 | NO, Nitric oxide, 0-100 ppm |
| 219 | NO2, Nitrogen dioxide, 0-10 ppm |
| 220 | NO2, Nitrogen dioxide, 0-30 ppm |
| 287 | NO2, Nitrogen dioxide, 0-100 ppm |
| 272 | O2, Oxygen, 0-30% Vol. |
| 284 | O3, Ozone, 0-1 ppm |
| Electrochemical with sinter (EF) | |
| 203 | CO, Carbon monoxide 0-100 ppm |
| 204 | CO, Carbon monoxide 0-300 ppm |
| 205 | CO, Carbon monoxide 0-1000 ppm |
| 266 | CO, Carbon monoxide 0-2000 ppm |
| 289 | CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm |
| 213 | H2S, Hydrogen sulfide 0-30 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| 231 | NH3, Ammonia 0-100 ppm |
| 232 | NH3, Ammonia 0-1000 ppm |
| 272 | O2, Oxygen 0-30% Vol. |
| Infrared with sinter (IF) | |
| 239 | CO2, Carbon dioxide, 0-5% Vol. |
| 526 | HFO-1234yf, 0-2,000 ppm |
| 533 | HFO-1234ze, 0-2000 ppm |
| 502 | R134A, 0-2,000 ppm |
| MOS with sinter (MO) | |
| 275 | H2S, Hydrogen sulfide 0-50 ppm |
| 214 | H2S, Hydrogen sulfide 0-100 ppm |
| Rock Solid with grid (RS) | |
| 301 | Cl2, Chlorine, 0-5 ppm (low HR) |
| 284 | O3, Ozone, 0-1 ppm |
| O = Head Option | |
| 0 | None |
| A | Standard |
| B | Heating |
| P = Custom configuration | |
| 0 | None |
| C | Custom |
Accessories
| Part Number | Description |
| Bracket | |
| 6132479 | FREEDOM ceiling-mount (screws not included) |
| 6125385 | FREEDOM GP/XP/Xi, universal wall-mounting Adapter Plate |
| 6125383 | Aluminium adapter plate for replacing a DG, DGi, OLCT 60, or CTX 300 with a FREEDOM GP/XP/Xi |
| 6125384 | Aluminium adapter plate for replacing a OLCT80, Microsafe, Model 100, iTrans2, Meridian, FREEDOM5000 with a FREEDOM GP/XP/Xi |
| Installation | |
| 6327910 | PTFE sampling cup, all gases, all FREEDOM GP/XP/Xi, OLCT 20, 40, 50, 60, 80 and 100 |
| 6327958 | Stainless Steel sampling cup, all gases, all FREEDOM GP/XP/Xi, OLCT 20, 40, 50, 60, 80 and 100 |
| 6793322 | Universal pitot tube with DN 80 flange (requires a detector with circulation cup) |
| 6327950 | Duct mounting adaptor |
| 6331169 | Wall Mounted Collecting Cone for FREEDOM GP/XP/Xi, OLC(T) 100 |
| 6331168 | Ceiling Mounted Collecting Cone for FREEDOM GP/XP/Xi, OLC(T) 80/100 |
| 6327911 | PTFE Remote calibration cup for FREEDOM GP/XP/Xi, OLCT 20, 60, 80 and 100 |
| 6327964 | SS Remote calibration cup for FREEDOM GP/XP/Xi, OLCT 20, 60, 80 and 100 |
| Protection | |
| 6329014 | Reinforced splash guard kit for OLC(T) 20, 60, 80 and 100 |
| 6329004 | Splash guard kit (plastic) for OLC(T) 20, 60, 80 and 100 |
| 6129010 | Splash guard kit (Stainless steel) for OLC(T) 20, 60, 80 and 100 |
| 6123783 | Stainless steel sunshield for FREEDOM XP/Xi detectors |
| 6125382 | Stainless steel protective guard for FREEDOM GP/XP/Xi detectors |
| 6336038 | PTFE protective filter for FREEDOM GP/XP/Xi cartridge. |
| 6136060 | Removable PTFE filter (for 6336038) |
| 6143590 | Plug M44 cell protection (to allow painting or cleaning operations around detector) |
| Maintenance | |
| B106255 | Samsung Galaxy Tab A9 8.7" Wi Fi tablet, 4 GB RAM / 64 GB storage, Grey, model SM X130. Suitable and usable in non-hazardous areas for configuration and field maintenance operations of FREEDOM GP/XP/Xi |
| 77024065 | Stylet magnétique pour FREEDOM GP/XP/Xi et iTrans 2 |
| 6145729 | 4 mm Allen key for FREEDOM GP |
| 6147881 | FREEDOM GP/XP/Xi tool kit including cartridge, cover removal tool (XP/Xi) removal tool, and 3 mm Allen key |
| 6331141 | Calibration cup (all detectors except CTX300 with semiconductor sensor and 700 Series, all gases) |
| Demo Kit |
|
| FREEDOM-XI-DEMO-KIT | Demonstration Kit comprising a FREEDOM Xi detector, O2 and H2S sensor modules, a sensor simulator, a steel demonstration panel, and a power supply. All components are supplied in a transport and storage case for easy handling. Designed for customer demonstrations, technical training sessions, and sales presentations, allowing realistic simulation of detector operation and maintenance functions. |
By submitting your details you consent to their use in accordance with our Privacy Notice