Product Features
  • NEW PRODUCT RELEASE
  • Total Versatility
  • Optimised maintenance designed for the future 
  • Smart Connectivity
  • Immediate Visibility
  • Applicable across all detection technologies
  • Sensor cartridges can be replaced without powering down
  • Maintenance can be performed without the need for hot work permits
  • Free Teledyne GF SYNC App available
  • FREEDOM GP and XP
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.
Gas Detector Transmitter for Hazardous Areas with unique features: the benchmark for critical environments

Designed for installations where downtime is not an option, the FREEDOM Xi represents the highest level of performance within the FREEDOM range.
Engineered for hazardous and potentially explosive atmospheres, and certified SIL2 / SC3, the FREEDOM Xi combines functional safety, embedded intelligence, and operational continuity.

Built on Teledyne’s proven expertise, it delivers reliable gas detection in the most demanding industrial environments while helping optimise long-term operational performance.
When gas detection becomes strategic, the FREEDOM Xi is the obvious choice for critical industrial environments.

 

The FREEDOM Xi is ideally suited for: 

  • Refineries and petrochemical facilities
  • Power generation and energy distribution 
  • Heavy industry  
  • 24/7 critical infrastructure
  • Highly regulated industrial sites                                                                                           

A detection technology for every risk

Because every site presents unique challenges, the FREEDOM Xi offers a wide range of detection technologies suited to specific hazards and environmental conditions. 

Whether monitoring toxic gases, oxygen depletion or enrichment, CO₂, or refrigerants, the FREEDOM Xi provides the most appropriate sensing technology: electrochemical or Rock Solid cells, infrared or semiconductor sensors. Each sensing cartridge is pre-calibrated for fast, tool-free commissioning and optimum accuracy from day one. 

This modular approach enables the FREEDOM Xi to adapt to virtually any industrial environment. The FREEDOM Xi features a single universal mainboard compatible with all detection technologies and gas types. 

                                                                       

 

A clear and intuitive user interface

The FREEDOM Xi’s interface is designed for intuitive operation with no need for specialised tools or complex procedures. Its multicolour TFT display provides comprehensive information at a glance, including real-time readings, detected gas, measurement units, live trend graphs and text-based configuration menus. 

Smooth navigation across the menus is achieved using four magnet-activated buttons, eliminating the need to open the housing in hazardous areas. 
Peripheral LEDs surrounding the display provide clear, long-distance visibility of the FREEDOM Xi’s status and interactions, even in bright ambient light. 

At a glance, operators can identify whether the unit is operating normally, in fault or alarm condition, or connected via Bluetooth to the GF Sync app. 
Overall, the interface is designed to simplify operations and enhance user confidence in the field. 


A display designed for harsh environments

In extreme temperatures, the optional LCD enables operation across a wide temperature range, from -40°C to +75°C. 

An exclusive hot-swap function for uninterrupted continuity

The hot-swap functionality, unique on the market, enables the replacement of the sensing cartridge (for toxic and flammable gas detection) while the device remains powered, without affecting the FREEDOM certification for hazardous areas. 

  • No hot work permit required
  • No power shutdown
  • No process interruption 

In critical environments, every minute matters. This unique capability ensures complete operational continuity, even during maintenance activities. 


Remote sensor head and dual detection

With its remote sensor head and Dual Detection capability, the FREEDOM Xi adapts to the constraints of any industrial site. The remote sensor head allows the sensing element to be installed up to 30 metres (100 ft) from the transmitter. 

The Dual Detection function enables two measurement points to be monitored using a single device. Less equipment. Less cabling. Greater flexibility. A solution designed to optimise installation while maintaining the highest level of performance. 

 

A modular design to suit every need

Because every industrial environment has its own specific constraints, the FREEDOM Xi offers a wide range of options to tailor detection to any configuration. This flexibility ensures seamless integration into all existing systems, whether simple or complex. 

 

                                 

 

 

Choose, Configure and Customise

  • Remote sensing head: The sensor can be installed up to 30 metres or 100 feet from the transmitter, facilitating installation in hard-to-reach areas. 
  • Communication:
    • Analogue output: 2- or 3-wire configuration depending on the detection technology. 
    • Sink or Source options
    • Adjustable 0–4 mA range 
    • Isolated 4–20 mA analogue output (optional). Modbus RS485 digital output (optional). 
    • Configurable 4–20 mA analogue input (optional). 
  • On-board relays: 
    • Three configurable alarm relays, one fault relay and an acknowledgement input for standalone local operation. 
  • Display:
    • TFT display with direct access to multilingual menus, trend curves, and detection data. Multicolour, backlit LCD for installation in the most demanding climatic environments. Display-free versions with status LEDs. 
  •  
  • Universal detection cartridge: 
    • All cells and sensors are compatible with the same main circuit board. This simplifies maintenance and reduces the number of part numbers. 
    • This modularity makes the FREEDOM Xi a universal solution, adaptable to any architecture, any industry and any security requirement. 
  • Dual detection:
    • Connection of two sensing cartridges to the FREEDOM Xi. All technology combinations are possible, either locally mounted or remotely installed. 

This modularity makes the FREEDOM Xi a universal solution, adaptable to any architecture, any industry and any security requirement. 

GF SYNC: the App that makes detection easier

Available FREE on the App Store and Google Play, the GF Sync app revolutionises gas detector management by providing instant access to all essential functions, while unlocking the full capabilities of the FREEDOM Xi:

  • Quick configuration: set up your detectors in just a few clicks and save the configurations for easy, error-free replication.
  • Simplified calibration: perform reliable and fully traceable calibration through a guided, step-by-step process.
  • Optimised maintenance: access event history, monitor sensor diagnostics and facilitate planned maintenance schedules proactively.
  • Digitalised monitoring: automatically generate calibration certificates that can be exported as .pdf or .csv files.
  • Enhanced cybersecurity: secure, encrypted communications, compliant with the latest and most stringent cybersecurity standards.

With GF Sync, deployment and operation become faster, safer and more efficient. Your safety, at your fingertips.


We're happy to help! Please submit via the 'send enquiry' button at the top of the page to place an order, or email [email protected] or call +44 330 088 0595, and a member of the team will get back to you.

Environmental
Operating Temperature -40° to 167°F ( -40° to +75°c) LCD Display
-4° to 131°F ( -30° to +55°c) TFT Display 
Operating humidity 0-99 % RH (non-condensing)
Storage conditions -4° to 104° F (-20° to +40°c ), 20-80 % RH (non-condensing)
Physical Specification
Material  Copper-free aluminium or Stainless Steel 316L
Weight Aluminium: 10,58 lbs (4,8 Kg), Spacer version: 11,13 lbs (5,05 Kg) (With Cartridge)
Stainless steel: 13,23 lbs (6,8 Kg), Spacer version: 16,58 lbs (7,52 Kg) (With Cartridge)
Dimension Standard: 9,25 x 6,46 x 5,98 ‘‘ (235 x 164 x 152 mm)
Spacer version: 9,25 x 6,46 x 6,89 ‘‘ (235 x 164 x 175 mm) (With relays option)
Enclosure Ingress Protection NEMA 4, IP 66
Cable Entries 4 conduit/cable entries, ¾ inch NPT or M20
Electrical Specification
Wiring 2 or 3 wires, 18 to 12 AWG 0,9 to 2,5 mm2)
Operating Voltage 24 VDC nominal, 2-wire 17,8 / 31,5 VDC, 3-wire 10 /31,8 VDC
Power consumption Transmitter: 35 W (3 wires), 1W (2wires)
Catalytic: 0,8 W, Infrared: 1 W, MEMS: 1 W,
Electrochemical Cell: 0,1 W, Semiconductor 0.6 W, MOS 0,6 W
Additional optional Relays: x W, Additional heating option: x W
Load impedance source 2 wires: 250 Ohm max, 3 wires: 500 Ohm max, non-isolated current source
Output
Analog Measuring range: 4- 20 mA, source
Discrete 0 to 4 mA configurable setting (fault, inhibit, maintenance call …)
Isolated 4-20 mA outputs, Configurable Source or Sink mode (Optional)
Digital HART™ Version 7 (3 wires only), RS485 Modbus RTU (Optional)
Relays (Optional) 3 user-configurable alarm relays SPDT 4 A/24 VDC, 4 A/230 VAC
1 fault relay SPDT 4 A/24 VDC, 4 A/230 VAC
Max cable size: 12 AWG, 2.5 mm2
User Interface
Display TFT or LCD display
Main screen: Gas reading, label, zone, gas name, measurement unit
Intuitive automatic calibration procedure
Multi-language: English, Spanish, French
2-level passwords, event data logging
TFT: Graphical multicolour high resolution, display size 1,65 x 1,25 inch (42 x 32 mm)
Trend Graph with selectable time scale showing current reading and alarm
LCD: Custom segmented LCD, 8 digits, display size 1.92 × 1.14 in (49 × 29 mm)
Version without display
LED Peripheral multicolour LED (Normal operation, Alarm, default, Inhibition, Calibration, Bluetooth communication)
Status icons LED (Normal operation, Alarm, default, Bluetooth)
Alarms 3 programmable alarms with set and reset
Memory Non-volatile memory ensures configuration parameters are retained in the event of power loss
Magnetic Switch 4 capacitive keys activatable with magnetic switch for menu navigation and acknowledgement
and validation operations
Wireless Bluetooth Communication
Version Bluetooth BLE 5, point-to-point mode
Option disable
Approval Encryption: AES-128, registered SIG, Cyber STD conception
App Teledyne GF Sync® - Free, available on the App Store and Google App
Distance Up to 49 ft (15 m)
Functionality Real-time reading, status, event history
Full detector setup (range, alarm, calibration, relays, optional parameters)
Calibration operation & report editing
Certification
Hazardous Area ATEX II 2(1) GD, Ex db ia [ia Ga] IIC T4..T6 Gb / Ex tb ia [ia Da] IIIC T135°C..T85°C Db IECEX, Ex db ia [ia Ga] IIC T4..T6 Gb / Ex tb ia [ia Da] IIIC T135°C..T85°C Db FM (Pending)
Metrologic Performance Flammable IEC 60079-29-1 (Pending)
H2S IEC62990-1 (Pending)
Cybersecurity Certified Cyber Resilience Act IEC 62443-4-2 (SL1)
Functional safety SIL 2 / SC3 High Demand (TÜV Pending)
Warranty
Transmitter 2-years
Sensor Catalytic Bead sensor: 2 years
Infrared sensor: CO2 3 years, refrigerant: 2 years
MEMS sensor: 2 years
Electrochemical sensor: cell-dependent
Rock Solid: 1 year
Semiconductor sensor: 1 year
Metal Oxide Semiconductor sensor: 2 years
Hub
Weight Aluminium 17.0 lbs (7,7 Kg) 
Dimension 15,75 x 6,46 x 6,89‘‘ (400 x 164 x 175 mm)
Enclosure Ingress Protection NEMA 4, IP 66
Remote Cartridge
Distance Remote until 98 ft (30 m), cable
Weight  Aluminium 4.37 lbs (1,98 Kg), Stainless Steel 7,52 lbs (3,41 Kg) (with cartridge)
Dimension 7,44 x 5,43 x 3,31‘‘ (189 x 138 x 84 mm)
Enclosure Ingress Protection NEMA 4, IP 66
Cable Entries 2 conduit/cable entries, ¾ inch NPT or M20
Hazardous Area ATEX II 2 GD, Ex db ia IIC T4..T6 Gb / Ex tb ia IIIC T135°C..T85°C Db
ATEX II 1 GD, Ex ia IIC T5 Ga / Ex ia IIIC T100°C Da
IECEX, Ex db ia IIC T4..T6 Gb / Ex tb ia IIIC T135°C..T85°C Db
IECEX, Ex ia IIC T5 Ga / Ex ia IIIC T100°C Da
FM (Pending)
Sensor Specification
Universal Detector cartridge Detector head accepts all sensor types
Sensor Types Combustible: Catalytic Bead, MEMS and Infrared
Toxic & Oxygen: Electrochemical and Rock Solid
Refrigerant gas: Infrared and Semiconductor
CO2: Infrared
H2S: Metal Oxide Semiconductor (MOS)
Hotswap Swappable cartridge under power and certified for hazardous areas
Gas Name Measuring Range Gas Code Teledyne Detection Technology Techno Code Teledyne Temperature Range Humidity Range Accuracy Response Time T90 Average life expectancy
            °F / °C % RH   s Month
C3H8 Propane 0- 100% LEL 005 Catalytic AP (CAT16) -40°C to 50°C 0 to 90   41 >60 months
C4H10 n-butane 0- 100% LEL 004 Catalytic AP (CAT16) -40°C to 50°C 0 to 90   51 >60 months
CH4 Methane 0- 100% LEL 002 Catalytic AP (CAT16) -40°C to 50°C 0 to 90   25 >60 months
H2 Hydrogène 0-100 %LEL 003 Catalytic AP (CAT16) -40°C to 50°C 0 to 90   12 >60 months
C5H12 Pentane 0- 100% LEL 051 Catalytic AP (CAT16) -40°C to 50°C 0 to 90   80 >60 months
C3H8 Propane 0- 100% LEL 005 Catalytic CB (VQ3) -40°C to 75°C 0 to 95 +/-1%LEL 27 >36 months
C4H10 Butane 0- 100% LEL 004 Catalytic CB (VQ3) -40°C to 75°C 0 to 95 +/-2% LEL 30 >36 months
CH4 Méthane 0-100 %LEL 002 Catalytic CB (VQ3) -40°C to 75°C 0 to 95 +/-1%LEL 20 >36 months
H2 Hydrogène 0-100 %LEL 003 Catalytic CB (VQ3) -40°C to 75°C 0 to 95 +/-4%LEL 11 >36 months
C5H12 Pentane 0- 100% LEL 051 Catalytic CB (VQ3) -40°C to 75°C 0 to 95   43 >36 months
Cl2 Chlore 0-10 ppm 224 Electrochem EC -20°C to 40°C 15 to 90   55 >24 months
CO Monoxyde de carbone 0-100 ppm 203 Electrochem EC -30°C to 50°C 15 to 90 +/-2% 24 >48 months
CO Monoxyde de carbone 0-1000 ppm 205 Electrochem EC -30°C to 50°C 15 to 90 +/-2% 24 >48 months
CO Monoxyde de carbone 0-300 ppm 204 Electrochem EC -30°C to 50°C 15 to 90 +/-2% 24 >48 months
CO Monoxyde de carbone 0-2000 ppm 266 Electrochem EC -30°C to 50°C 15 to 90 +/-2% 24 >48 months
H2S Hydrogène sulfuré 0-30 ppm 213 Electrochem EC -30°C to 50°C 15 to 90   27 >48 months
H2S Hydrogène sulfuré 0-100 ppm 214 Electrochem EC -30°C to 50°C 15 to 90   27 >48 months
NH3 Ammoniac 0-1000 ppm 232 Electrochem EC -40°C to 50°C 15 to 90   44 >24 months
NH3 Ammoniac 0-1000 ppm 265 Electrochem EC -40°C to 50°C 15 to 90   44 >24 months
O2 Oxygène 0-30 %vol 272 Electrochem EC -40°C to 60°C 15 to 90   20 >60 months
O3 Ozone 0-1 ppm 284 Electrochem EC -20°C to 40°C 15 to 90   41 >18 months
NH3 Ammoniac 0-300 ppm 273 Electrochem EC -40°C to 50°C 15 to 90   44 >24 months
NO Monoxyde d'azote 0-100 ppm 216 Electrochem EC -30°C to 50°C 15 to 90 +/-5% 24 >12 months
NO2 Dioxyde d'azote 0-10 ppm 219 Electrochem EC -30°C to 50°C 15 to 90   41 >24 months
NO2 Dioxyde d'azote 0-100 ppm 287 Electrochem EC -30°C to 50°C 15 to 90   41 >24 months
C2H4O Oxyde d'éthylène 0-30 ppm 244 Electrochem EC -20°C to 50°C 15 to 90   150 >24 months
O2 Oxygène 0-10 %vol 282 Electrochem EC -40°C to 60°C 15 to 90   20 >60 months
Base - A B C - D E F GH IJK L M
A = Enclosure material & cable entries
3 Aluminium, M20
4 Aluminium, 3/4NPT
5 Stainless Steel, M20
6 Stainless Steel, 3/4NPT
B = Extension
0 None
2 with aluminium spacer
3 with Stainless Steel Spacer
A HUB - Double head
B HUB - Double head + with aluminium spacer
C = Head option
1 Local Cartridge
3 Remote Cartridge, Aluminium, M20
4 Remote Cartridge, Aluminium, 3/4NPT
5 Remote Cartridge, Stainless Steel, M20
6 Remote Cartridge, Stainless Steel, 3/4NPT
7 Remote Cartridge, Stainless Steel, M20, Zone 0
8 Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0
C Input External (no cartridge)
D HUB with 2 On-board cartridges
E HUB with 1 On-board cartridge and 1 remote cartridge
F HUB with 2 remote cartridges
D = Display, wires
A 3 Wires, LCD + HART
B 3 Wires, TFT + HART
C 3 Wires, Blind + HART
D 2 Wires, LCD
E 2 Wires, Blind
E = Output option
0 None
1 2nd 4-20mA output
F = Relays, I/O board
0 None
1 Relays <35V, +24V Out, Ack
2 4/20mA or GD10P Entry
3 Relays >35V, 4/20mA or GD10P Entry
7 Relays >35V, +24V Out, Ack
8 Relays >35V, +24V Out, Ack, 4/20mA or GD10P Entry
GH = Cell technology
00 None
AP Catalytic bead poison-resistant (Sinter)
CB Catalytic bead (Sinter)
EC Echem (grid)
EF Echem (Sinter)
IF Infrared (Sinter)
MO MOS (Sinter)
RS Rock Solid (Grid)
IJK = Gas and range
000 None
Catalytic bead poison-resistant with sinter (AP)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
IJK = Gas and range
003 H2, Hydrogen 100% LEL
Catalytic bead with sinter (CB)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
003 H2, Hydrogen 100% LEL
Electrochemical with grid (EC)
224 Cl2, Chlorine, 0-10 ppm
203 CO, Carbon monoxide, 0-100 ppm
204 CO, Carbon monoxide, 0-300 ppm
205 CO, Carbon monoxide, 0-1000 ppm
266 CO, Carbon monoxide, 0-2000 ppm
289 CO/H2nul, Carbon monoxide, 0-1000 ppm
244 C2H4O, Ethylene oxide, 0-30 ppm
213 H2S, Hydrogen sulfide, 0-30 ppm
214 H2S, Hydrogen sulfide, 0-100 ppm
215 H2S, Hydrogen sulfide, 0-1000 ppm
311 H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C)
231 NH3, Ammonia, 0-100 ppm
232 NH3, Ammonia, 0-1000 ppm
216 NO, Nitric oxide, 0-100 ppm
219 NO2, Nitrogen dioxide, 0-10 ppm
220 NO2, Nitrogen dioxide, 0-30 ppm
287 NO2, Nitrogen dioxide, 0-100 ppm
272 O2, Oxygen, 0-30% Vol.
284 O3, Ozone, 0-1 ppm
Electrochemical with sinter (EF)
203 CO, Carbon monoxide 0-100 ppm
204 CO, Carbon monoxide 0-300 ppm
205 CO, Carbon monoxide 0-1000 ppm
266 CO, Carbon monoxide 0-2000 ppm
289 CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm
213 H2S, Hydrogen sulfide 0-30 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
231 NH3, Ammonia 0-100 ppm
232 NH3, Ammonia 0-1000 ppm
272 O2, Oxygen 0-30% Vol.
Infrared with sinter (IF)
239 CO2, Carbon dioxide, 0-5% Vol.
526 HFO-1234yf, 0-2,000 ppm
533 HFO-1234ze, 0-2000 ppm
502 R134A, 0-2,000 ppm
MOS with sinter (MO)
275 H2S, Hydrogen sulfide 0-50 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
Rock Solid with grid (RS)
301 Cl2, Chlorine, 0-5 ppm (low HR)
284 O3, Ozone, 0-1 ppm
L = Head Option
0 None
A Standard
B Heating
M = Custom configuration
0 None
C Custom

HUB - To be quoted if FREEDOM XI is fitted with a HUB

Base - A BC - DEF G H - IJK LMN O P 
A = Head 1 Option
1 Local Cartridge
3 Remote Cartridge, Aluminium, M20
4 Remote Cartridge, Aluminium, 3/4NPT
5 Remote Cartridge, Stainless Steel, M20
6 Remote Cartridge, Stainless Steel, 3/4NPT
7 Remote Cartridge, Stainless Steel, M20, Zone 0
8 Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0
BC = Cell technology
00 None
AP Catalytic bead poison resistant (Sinter)
CB Catalytic bead (Sinter)
EC Echem (grid)
EF Echem (Sinter)
IF Infrared (Sinter)
MO MOS (Sinter)
RS Rock Solid (Grid)
DEF = Gas and range
000 None
Catalytic bead poison resistant with sinter (AP)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
003 H2, Hydrogen 100% LEL
Catalytic bead with sinter (CB)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
003 H2, Hydrogen 100% LEL
Electrochemical with grid (EC)
224 Cl2, Chlorine, 0-10 ppm
203 CO, Carbon monoxide, 0-100 ppm
204 CO, Carbon monoxide, 0-300 ppm
205 CO, Carbon monoxide, 0-1000 ppm
266 CO, Carbon monoxide, 0-2000 ppm
289 CO/H2nul, Carbon monoxide, 0-1000 ppm
244 C2H4O, Ethylene oxide, 0-30 ppm
213 H2S, Hydrogen sulfide, 0-30 ppm
214 H2S, Hydrogen sulfide, 0-100 ppm
215 H2S, Hydrogen sulfide, 0-1000 ppm
311 H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C)
231 NH3, Ammonia, 0-100 ppm
232 NH3, Ammonia, 0-1000 ppm
216 NO, Nitric oxide, 0-100 ppm
219 NO2, Nitrogen dioxide, 0-10 ppm
220 NO2, Nitrogen dioxide, 0-30 ppm
287 NO2, Nitrogen dioxide, 0-100 ppm
272 O2, Oxygen, 0-30% Vol.
284 O3, Ozone, 0-1 ppm
Electrochemical with sinter (EF)
203 CO, Carbon monoxide 0-100 ppm
204 CO, Carbon monoxide 0-300 ppm
205 CO, Carbon monoxide 0-1000 ppm
266 CO, Carbon monoxide 0-2000 ppm
289 CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm
213 H2S, Hydrogen sulfide 0-30 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
231 NH3, Ammonia 0-100 ppm
232 NH3, Ammonia 0-1000 ppm
272 O2, Oxygen 0-30% Vol.
Infrared with sinter (IF)
239 CO2, Carbon dioxide, 0-5% Vol. no charge
526 HFO-1234yf, 0-2,000 ppm
533 HFO-1234ze, 0-2000 ppm
502 R134A, 0-2,000 ppm
MOS with sinter (MO)
275 H2S, Hydrogen sulfide 0-50 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
Rock Solid with grid (RS)
301 Cl2, Chlorine, 0-5 ppm (low HR)
284 O3, Ozone, 0-1 ppm
G = Head Option
0 None
A Standard
B Heating
H = Custom configuration
0 None 
C Custom
I = Head 2 Option
1 Local Cartridge
3 Remote Cartridge, Aluminium, M20
4 Remote Cartridge, Aluminium, 3/4NPT
5 Remote Cartridge, Stainless Steel, M20
6 Remote Cartridge, Stainless Steel, 3/4NPT
7 Remote Cartridge, Stainless Steel, M20, Zone 0
8 Remote Cartridge, Stainless Steel, 3/4NPT, Zone 0 £
JK = Cell technology
00 None
AP Catalytic bead poison resistant (Sinter)
CB Catalytic bead (Sinter)
EC Echem (grid)
EF Echem (Sinter)
IF Infrared (Sinter)
MO MOS (Sinter)
RS Rock Solid (Grid)
LMN = Gas and range
000 None
Catalytic bead poison resistant with sinter (AP)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
003 H2, Hydrogen 100% LEL
Catalytic bead with sinter (CB)
002 CH4, Methane 100% LEL
005 C3H8, Propane 100% LEL
004 C4H10, Butane 100% LEL
051 C5H12, Pentane 100% LEL
003 H2, Hydrogen 100% LEL
Electrochemical with grid (EC)
224 Cl2, Chlorine, 0-10 ppm
203 CO, Carbon monoxide, 0-100 ppm
204 CO, Carbon monoxide, 0-300 ppm
205 CO, Carbon monoxide, 0-1000 ppm
266 CO, Carbon monoxide, 0-2000 ppm
LMN = Gas and range
Electrochemical with grid (EC)
289 CO/H2nul, Carbon monoxide, 0-1000 ppm
213 H2S, Hydrogen sulfide, 0-30 ppm
214 H2S, Hydrogen sulfide, 0-100 ppm
311 H2S, Hydrogen sulfide, 0-100 ppm (T° up to +70°C)
231 NH3, Ammonia, 0-100 ppm
232 NH3, Ammonia, 0-1000 ppm
216 NO, Nitric oxide, 0-100 ppm
219 NO2, Nitrogen dioxide, 0-10 ppm
220 NO2, Nitrogen dioxide, 0-30 ppm
287 NO2, Nitrogen dioxide, 0-100 ppm
272 O2, Oxygen, 0-30% Vol.
284 O3, Ozone, 0-1 ppm
Electrochemical with sinter (EF)
203 CO, Carbon monoxide 0-100 ppm
204 CO, Carbon monoxide 0-300 ppm
205 CO, Carbon monoxide 0-1000 ppm
266 CO, Carbon monoxide 0-2000 ppm
289 CO/H2 nul, Carbon monoxide/Hydrogen nul 0-1,000 ppm
213 H2S, Hydrogen sulfide 0-30 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
231 NH3, Ammonia 0-100 ppm
232 NH3, Ammonia 0-1000 ppm
272 O2, Oxygen 0-30% Vol.
Infrared with sinter (IF)
239 CO2, Carbon dioxide, 0-5% Vol.
526 HFO-1234yf, 0-2,000 ppm
533 HFO-1234ze, 0-2000 ppm
502 R134A, 0-2,000 ppm
MOS with sinter (MO)
275 H2S, Hydrogen sulfide 0-50 ppm
214 H2S, Hydrogen sulfide 0-100 ppm
Rock Solid with grid (RS)
301 Cl2, Chlorine, 0-5 ppm (low HR)
284 O3, Ozone, 0-1 ppm
O = Head Option
0 None
A Standard
B Heating
P = Custom configuration
0 None
C Custom

Accessories

Part Number  Description
  Bracket
6132479 FREEDOM ceiling-mount (screws not included)
6125385 FREEDOM GP/XP/Xi, universal wall-mounting Adapter Plate
6125383 Aluminium adapter plate for replacing a DG, DGi, OLCT 60, or CTX 300 with a FREEDOM
GP/XP/Xi
6125384 Aluminium adapter plate for replacing a OLCT80, Microsafe, Model 100, iTrans2, Meridian,
FREEDOM5000 with a FREEDOM GP/XP/Xi
Installation
6327910 PTFE sampling cup, all gases, all FREEDOM GP/XP/Xi, OLCT 20, 40, 50, 60, 80 and 100
6327958 Stainless Steel sampling cup, all gases, all FREEDOM GP/XP/Xi, OLCT 20, 40, 50, 60, 80
and 100
6793322 Universal pitot tube with DN 80 flange (requires a detector with circulation cup)
6327950 Duct mounting adaptor
6331169 Wall Mounted Collecting Cone for FREEDOM GP/XP/Xi, OLC(T) 100
6331168 Ceiling Mounted Collecting Cone for FREEDOM GP/XP/Xi, OLC(T) 80/100
6327911 PTFE Remote calibration cup for FREEDOM GP/XP/Xi, OLCT 20, 60, 80 and 100
6327964 SS Remote calibration cup for FREEDOM GP/XP/Xi, OLCT 20, 60, 80 and 100
Protection
6329014 Reinforced splash guard kit for OLC(T) 20, 60, 80 and 100
6329004 Splash guard kit (plastic) for OLC(T) 20, 60, 80 and 100
6129010 Splash guard kit (Stainless steel) for OLC(T) 20, 60, 80 and 100
6123783 Stainless steel sunshield for FREEDOM XP/Xi detectors
6125382 Stainless steel protective guard for FREEDOM GP/XP/Xi detectors
6336038 PTFE protective filter for FREEDOM GP/XP/Xi cartridge.
6136060 Removable PTFE filter (for 6336038)
6143590 Plug M44 cell protection (to allow painting or cleaning operations around detector)
Maintenance
B106255 Samsung Galaxy Tab A9 8.7" Wi Fi tablet, 4 GB RAM / 64 GB storage, Grey, model
SM X130. Suitable and usable in non-hazardous areas for configuration and field maintenance
operations of FREEDOM GP/XP/Xi
77024065 Stylet magnétique pour FREEDOM GP/XP/Xi et iTrans 2
6145729 4 mm Allen key for FREEDOM GP
6147881 FREEDOM GP/XP/Xi tool kit including cartridge, cover removal tool (XP/Xi) removal tool,
and 3 mm Allen key
6331141 Calibration cup (all detectors except CTX300 with semiconductor sensor and 700 Series, all
gases)
Demo Kit
FREEDOM-XI-DEMO-KIT Demonstration Kit comprising a FREEDOM Xi detector, O2 and H2S sensor modules, a
sensor simulator, a steel demonstration panel, and a power supply. All components are
supplied in a transport and storage case for easy handling.
Designed for customer demonstrations, technical training sessions, and sales presentations,
allowing realistic simulation of detector operation and maintenance functions.
Write Your Own Review
You're reviewing:Teledyne Freedom Xi Fixed Gas Detector
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice