Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Toxic gas monitor (OLCT 10)
  • Combustible gas monitor (OLC 10)
  • Fast and accurate response
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Teledyne Oldham OLCT 10 & OLC 10 Fixed Gas Detector

SKU
OldhamOLCT10&OLC10FixedGasDetector

The Teledyne Oldham OLCT 10 & OLC 10 are gas monitors for applications within boiler rooms and parking garages, offering users the best cost effective solution for continuously monitoring toxic (OLCT 10) or flammable gases and vapors (OLC 10) in ambient air.

  • ATEX Approval for use in hazardous areas
  • IP66

The Oldham OLCT 10 & OLC 10 both benefit from being simple to install and operate, being compatable with the MX 15 control unit. This combination helps meet requirements from the most demanding user applications.

Detector OLC 10 - Wheatstone bridge
  • 6513559 Flammable gas sensor type OLC 10 ATEX II 3 G - EEx nA IIC T6 approved - Range 0-100% LEL CH4 / C4H10 / C3H8 / H2
  • 6513566 Flammable gas sensor type OLC 10 TWIN ATEX II 3 G - EEx nA IIC T6 approved - Allows to link 2 OLC 10 TWIN detectors to one single channel without any junction box - Quote 2 OLC 10 TWIN in that case. - Range 0-100% LEL CH4 / C4H10 / C3H8 / H2
Detector OLCT 10 - 4-20 mA versions
  • OLCT10-001 OLCT 10 analog transmitter, without display, 0-100% LEL CH4 (5% vol), ATEX II 3G, Ex nA IIC T4, IP65
  • OLCT10-002 OLCT 10 analog transmitter, without display, 0-100% LEL CH4 (4.4% vol), ATEX II 3G, Ex nA IIC T4, IP65
  • OLCT10-003 OLCT 10 analog transmitter, without display, 0-100% LEL H2 (hydrogen), ATEX II 3G, Ex nA IIC T4, IP65
  • OLCT10-004 OLCT 10 analog transmitter, without display, 0-100% LEL C4H10 (butane), ATEX II 3G, Ex nA IIC T4, IP65
  • OLCT10-005 OLCT 10 analog transmitter, without display, 0-100% LEL C3H8 (propane), ATEX II 3G, Ex nA IIC T4, IP65
  • 6513567 OLCT 10 analog transmitter, without display, 0-300ppm CO Sensor, 4-20 mA output, ATEX II 3G, Ex nA IIC T4, IP65
  • 6513569 OLCT 10 analog transmitter, without display, 0-100ppm NO Sensor, 4-20 mA output, ATEX II 3G, Ex nA IIC T4, IP65
  • 6513570 OLCT 10 analog transmitter, without display, 0-30ppm NO2 Sensor, 4-20 mA output, ATEX II 3G, Ex nA IIC T4, IP65
Detector OLCT 10 - 4-20 mA Semi-conductor versions - for use in non Hazardous area only
  • OLCT10-664 OLCT 10 analog transmitter, without display, 0-100% LEL CH4 (5%vol)
  • OLCT10-665 OLCT 10 analog transmitter, without display, 0-100% LEL CH4 (4.4%vol)
  • OLCT10-666 OLCT 10 analog transmitter, without display, 0-100% LEL C4H10 (butane)
  • OLCT10-667 OLCT 10 analog transmitter, without display, 0-100% LEL C3H8 (propane)
  • OLCT10-510 OLCT 10 analog transmitter, without display, 0-2000ppm FX56
  • OLCT10-662 OLCT 10 analog transmitter, without display, 0-1,000ppm HFO-1234YF
  • OLCT10-525 OLCT 10 analog transmitter, without display, 0-1,000ppm HFO-1234ZE
  • OLCT10-505 OLCT 10 analog transmitter, without display, 0-1% volume R11
  • OLCT10-500 OLCT 10 analog transmitter, without display, 0-1% volume R12
  • OLCT10-501 OLCT 10 analog transmitter, without display, 0-2000ppm R22
  • OLCT10-506 OLCT 10 analog transmitter, without display, 0-1% volume R23
  • OLCT10-515 OLCT 10 analog transmitter, without display, 0-1000ppm R32
  • OLCT10-521 OLCT 10 analog transmitter, without display, 0-1000ppm R245FA
  • OLCT10-509 OLCT 10 analog transmitter, without display, 0-2000ppm R123
  • OLCT10-502 OLCT 10 analog transmitter, without display, 0-2000ppm R134A
  • OLCT10-511 OLCT 10 analog transmitter, without display, 0-2000ppm R143A
  • OLCT10-512 OLCT 10 analog transmitter, without display, 0-2000ppm R404A
  • OLCT10-514 OLCT 10 analog transmitter, without display, 0-1000ppm R410A
  • OLCT10-517 OLCT 10 analog transmitter, without display, 0-1000ppm R407C
  • OLCT10-519 OLCT 10 analog transmitter, without display, 0-1,000ppm R407F
  • OLCT10-518 OLCT 10 analog transmitter, without display, 0-4,000ppm R408A
  • OLCT10-520 OLCT 10 analog transmitter, without display, 0-4,000ppm R434A (RS45)
  • OLCT10-513 OLCT 10 analog transmitter, without display, 0-2000ppm R507
OLCT 10 Accessories
  • NPO10GB User manual OLCT 10 in English language, hard copy
  • NPO10FR User manual OLCT 10 in French language, hard copy
  • 6147872 OLCT 10 tool kit (includes one screwdriver and one flat cable for signal measurement)
  • 6123717 Shock-guard protector for OLC(T)10 and 300 series
  • 6331141 Calibration cup (all detectors except OLCT-IR, all gases)
OLCT 10N Detectors - ATEX and IECEX approved II 3 G
  • OLCT10N-001 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100% LEL CH4 (5% vol)
  • OLCT10N-002 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100% LEL CH4 (4.4% vol)
  • OLCT10N-003 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100% LEL H2
  • OLCT10N-004 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100% LEL C4H10
  • OLCT10N-005 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100% LEL C3H8
  • OLCT10N-200 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-30% vol O2 (life time for the sensor: 2 years)
  • OLCT10N-272 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-30% vol O2 (life time for the sensor: 5 years)
  • OLCT10N-204 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-300ppm CO
  • OLCT10N-205 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-1,000ppm CO
  • OLCT10N-213 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-30ppm H2S
  • OLCT10N-214 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100ppm H2S
  • OLCT10N-216 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100ppm NO
  • OLCT10N-217 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-300ppm NO
  • OLCT10N-219 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-10ppm NO2
  • OLCT10N-220 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-30ppm NO2
  • OLCT10N-231 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-100ppm NH3
  • OLCT10N-232 OLCT 10N digital transmitter, without display, ATEX 3G, IP65, 0-1000ppm NH3
  • OLCT10N-252 OLCT 10N digital transmitter, without display, IP65, 0-5000ppm CO2 for use in non Hazardous area only
  • OLCT10N-239 OLCT 10N digital transmitter, without display, IP65, 0-5% vol CO2 for use in non Hazardous area only
  • OLCT10N-241 OLCT 10N digital transmitter, without display, IP65, 0-100% vol CO2 for use in non Hazardous area only
OLCT 10N Accessories
  • 6331163 Calibration kit for CPS10 and OLCT 10N (including a bar and a magnetic calibration cap)
  • 6123717 Shock-guard protector for OLC(T) 10 and 300 series
OLCT 10N replacement sensor
  • 6798301 CO 0-300 / 0-1000ppm (OLCT 10 / OLCT 10N / CPS10)
  • 6113332 NO2 0-10 / 0-30ppm (OLCT 10 / OLCT 10N / CPS10)
  • 6113341 H2S 0-30 / 0-100ppm replacement sensor for OLCT 10N
  • 6799345 O2 0-30% Vol. (OLCT 10N) - 2 year life time
  • 6113720 O2 0-30% Vol. (OLCT 10N) - 5 year life time
  • 6113331 NO 0-100 / 0-300ppm (OLCT 10 / OLCT 10N / CPS 10)
  • 6314118 NH3 0-100ppm (OLCT 10N)
  • 6314119 NH3 0-1000ppm (OLCT 10N)
  • 6314196 CO2 0-5000ppm (OLCT 10N)
  • 6314195 CO2 0-5% vol (OLCT 10N)
  • 6314197 CO2 0-100% vol (OLCT 10N)
Write Your Own Review
You're reviewing:Teledyne Oldham OLCT 10 & OLC 10 Fixed Gas Detector
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice