Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
The Teledyne Oldham OLCT 60 is the latest generation of high-quality gas detector, meeting the needs of a wide variety of industrial applications.
OLCT 60 Key Features:
There are several versions of the OLCT 60 available including XP or IS sensor (toxic or oxygen versions) and remote or onboard sensor. The sensor can be installed remotely up to 15 meters (standard) using the OLCT 60AD version. This allows for detection in inaccessible locations, or in Zone 0 in the case of the intrinsically safe (IS) version.
Rugged and resistant to corrosion, the OLCT 60 is made of 316L stainless steel. Pre-calibrated sensors can be disconnected by turning the head of the unit. These "smart" sensors can be calibrated outside hazardous areas.
XP Transmitter with XP sensor | XP transmitter with IS sensor | |
Sensor: | Catalytic / Electrochemical / Semi conductor / Infrared | Electrochemical |
Detected gases: | Explosive or toxic gases, O2 , VOC and refrigerant |
Toxic gases or O2 |
Material: | Epoxy coated aluminium + 316 stainless steel sensor | Epoxy coated aluminium + 316 stainless steel sensor |
Pre-calibrated block : | yes | yes |
Power supply: | 16 to 30 V DC | 16 to 30 V DC |
Average consumption: | 140 mA (catalytic) • 80 mA (electrochemical) • 120 mA (infrared sensor) |
80 mA |
Output signal: | 0 - 23 mA (4-20 mA reserved for measurement) | 0-23 mA (4-20 mA reserved for measurement) |
Cable: | • 3 active wires, shielded cable | 3 active wires, shielded cable |
Max. cable loop resistance / lenght : | Catalytic: 32 Ω / 1 km at 1.5 mm2 (16 AWG) • Electrochemical and XP IR: 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) |
with OLDHAM controller: 48 Ω / 1.5 km at 1.5 mm2 (16 AWG) |
Ingress protection: | IP 66 | IP 66 |
Approvals: | ATEX II 2 GD • EEx d IIC T6 Gb - Ex tb IIIC T85° C Db • O2 & LEL versions are consistent with SIL2 • Electromagnetic compatibility according to EN50270 |
• ATEX II 2 GD and ATEX II 2(1) GD • Ex d ia IIC T4 Gb - Ex tb IIIC T135°C Db (local sensor) • Ex d [ia Ga] IIC T4 Gb - Ex tb [ia Da] IIIC T135°C Db (offset sensor) • O2 & LEL versions are consistent with SIL2 • Electromagnetic compatibility according to EN50270 |
Weight: | • 2.1 kg | • 2.1 kg |
Dimensions: | 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches | • 154 x 186 x 121 mm / 6.06 x 7.32 x 4.76 inches |
Operating temperature: | 20°C to +60°C | -20°C to +60°C |
GAS TRANSMITTER type OLCT 60 approved ATEX II 2 GD (fitted with XP sensor) - delivered without cable-gland |
|
---|---|
OLCT 60 Infrared version |
|
GAS TRANSMITTER type OLCT 60 with local IS sensor / ATEX II 2 GD transmitter approved - delivered without cable-gland |
|
GAS TRANSMITTER type OLCT 60D with remote XP sensor (15m) / ATEX II 2 GD transmitter approved - delivered without cable-gland / ATEX II 2 GD remote sensor approved |
|
OLCT 60 Infrared version with remote XP sensor |
|
GAS TRANSMITTER type OLCT 60D with remote IS sensor / ATEX II 2 GD transmitter approved - delivered without cable-gland / ATEX II 1 GD remote sensor approved |
|
ACCESSORIES FOR OLCT 60 |
|
By submitting your details you consent to their use in accordance with our Privacy Notice