Sign up for our latest offers
Newsletter
By submitting your details you consent to their use in accordance with our Privacy Notice
At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates.
The Honeywell RAE Systems AreaRAE Plus Transportable Gas Detector provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to-configure device. Plus, you’ll have vital details about threats happening in real time—arming you with the information you need to act quickly.
Features and Benefits:
Application:
Spec | |
---|---|
DIMENSIONS |
314 x 306 x 166 mm (with rubber boot) 12.36” x 12.04” x 6.53” (with rubber boot) |
WEIGHT | 6.3 kg (13.88 lb) full option configuration 6.5 kg ( 14.33 lb) full option configuration (+RAEMet) |
GAS SENSORS SLOTS | up to 7; see Sensor list |
ADDITIONAL SENSORS | RAEMet (Wind Speed, Wind Direction, Temperature & Humidity) |
GPS | Standard equipment in every unit |
BATTERY | Rechargeable 7.2 V / 10 Ah Li-ion battery pack with built-in charger Alkaline Battery Adapter |
OPERATING HOURS | ~20 hours with wireless connectivity on Li-ion battery pack Specification at room temperature (20°C) |
DISPLAY | Large 240 x 320 pixel LCD backlit display 64 x 85 mm / 2.5” x 3.33” |
KEYPADS | 3 operation and programming keys |
ALARMS | Multi-tone 108 dB buzzer @ 3.3 ft / 1 m, Bright LED 360 degree |
DATA LOGGING | Continuous data logging (90 days for 7 gas sensors, 1 Gamma sensor, 1 RAEMet (wind speed & direction, temp and RH), and GPS at 1 min intervals, 24/7) |
DATA STORAGE | 24M bytes (memory full action: stop when full or Wrap around) |
DATA INTERVAL | User-configurable from 1 to 3,600 sec |
WIRELESS | Standard Bluetooth Low Energy module (BT4.0) and GPS Primary radio module: - Long range ISM License Free 900 MHz or 2.4 GHz radio - IEEE 802.11 b/g Wi-Fi Secondary radio module: Short range IEEE 802.15.4 900 MHz or 868MHz Mesh Radio Wireless range3: Up to 2 miles (3 km) for ISM 900 MHz; Up to 1.2 miles (2 km) for ISM 2.4 GHz; Up to 330 ft (100m) for Wi-Fi; Up to 660 ft (200m) for Mesh secondary radio; Up to 15 ft (5m) for BLE. Wireless Approval: FCC Part 15, CE R&TTE, Others4 |
COMMUNICATION | Communicates to ProRAE Studio II via USB cable to PC; Wireless data and alarm status transmission via Wi-Fi or ISM modem; Act as gateway to connect up to 8 remote instruments (using secondary radio module) |
SAFETY CERTIFICATION | US / Canada: Class 1, Division 2 Groups A, B, C, D |
SAMPLING PUMP |
Built-in pump, typical flow rate 450 cc/min |
TEMPERATURE | -20 °C to +50 °C / (- 4 °F to +122 °F) |
HUMIDITY | 0% to 95% relative humidity (non-condensing) |
INGRESS PROTECTION (IP) | IP 65 |
PERFORMANCE TESTS | MIL-STD-810G and 461F LEL CSA C2.2No. 152, ISA-12.13.01 |
HUMIDITY | Four years for O2 Liquid Oxygen sensors Three years for CO, and H2S sensors Two years for non-consumable components, catalytic LEL sensor and 10.6eV 7R+ PID lamp One year on all other sensors, battery, and other consumable parts Six months for 9.8eV lamp PID sensor |
By submitting your details you consent to their use in accordance with our Privacy Notice