In stock for next day delivery (only for the UK)
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Life-safety performance approved; ATEX & CSA
  • 15-year warranty IR sources - solid state optics
  • No field recalibration
  • Dual skin weather protector – no filters/gauzes or sinters
  • Planned maintenance with HART®
  • SIL 2/3 certified
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Teledyne Oldham Simtronics GD10P Infrared Point Gas Detector

SKU
GD10P

The Teledyne Oldham Simtronics GD10P Infrared Point Gas Detector (formally known as SIMRAD GD10P) has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.

The GD10P infrared gas detectors differ from all other models because they utilise silicon-based solid-state infrared sources. The complete optomechanical design and construction are so stable that an ultra-fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

Teledyne offers the longest combined detector and IR source warranty on the market.

For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using the existing cabling and control modules. The unit is supplied with worldwide performance and hazardous area approvals. Suitable for use in SIL 2 & SIL 3 systems. An industry standard HART® interface is used for the configuration of the optical fast response time and special fault levels as well as access to extended maintenance data.

Features and Benefits:

  • Solid-state IR sources for superior long-term performance compared to filament lamps
  • A high IR source flash rate provides improved stability and speed of response 
  • True dual path, double compensation optical design means no recalibration. All changes in the optical path are accounted for and monitored. 
  • A selectable response rate makes this the fastest IR point detector on the market, ideal for speed-critical applications 
  • Dual layer weather protector requires no mesh, gauze, hydrophobic filters or sinters. No delay, no failure on demand 
  • An early, dirty optics warning allows for improved preventative maintenance 
  • The integral termination compartment reduces installation time. This unit is ready to use, out of the box 
  • Low power consumption reduces the load on the UPS 
  • Independently heated mirrors and lenses provide high-performance detection in rough environmental conditions

 

Applications:

  • FPSO/ FSO/ MOPU 
  • Marine/ Jack up Rigs 
  • Oil & Gas Offshore Drilling Rigs 
  • Chemical and Petrochemical Plants
  • Waste Disposal 
  • Gas Turbines 
  • General Industry

 

Approvals:

  • ATEX: Certificate Nemko 07ATEX1438 
  • IECEx: Certificate IECEx NEM 07.0006 
  • CSA: C22.2 No. 152, Certificate 1773527 
  • SIL: Certificate TüV 968/FSP 1186.00/15 
  • Other: ABS, INMETRO (UL variant available)

 

Gases:

SYMBOL DESCRIPTION
C₂H₄ Ethylene
C₃H₈ Propane
C₃H₈ Butane
CH₄ Methane Gas Detectors

 

For information about the Teledyne Oldham Simtronics GD10P CO2 IR Point Gas Detector, please click here.

 

This product is formally known as the SIMRAD GD10P.

General
Technology IR-absorption, dual wavelength, dual path
IR-source Solid state IR source
Gases detected Hydrocarbons (for CO2
 see separate data sheet) 
Self-test Continuous
Calibration Factory set, no field recalibration
Configuration HART protocol 
Performance
Accuracy
Refers to -20°c to +45°c
±3% FS between 0-50 % reading
±5% FS between 50-100 % reading
Response time Methane
T20 = 0.2 Sec
T50 = 0.4 Sec
T90 = 1.0 Sec
Other gases
T20 < 1.0 Sec
T50 < 2.5 Sec
T90 < 6.0 Sec 
Output signal
Standard Current source 4 – 20 mA, max. Load
Impedance 500 ohm
Option Current sink 4 – 20 mA
HART® Maintenance and configuration
Detector Faults (HART
configurable)
- Early clean optics
- Dirty optics
- Detector failure
Pre warning (2 mA)
Dirt accumulation (1 mA)
Internal fault (0 mA) 
Electrical
Power supply 24V DC (18 - 32V DC) 
Power consumption Approx. 3.5 W 
Connection 3-wire shielded cable (0.5-2.5mm²) 
Cable entry M20 Ex e cable gland
Temperature range  
Storage -40°C to +70°C (-40°F to +158°F) 
Operating -40°C to +60°C (-40°F to +140°F)
Humidity
(Operation)
0- 100% RH
Explosion proof housing
Ingress Protection IP66/IP67
Housing material Stainless Steel SIS2343 (ASTM316)
Weight Approx. 2.9 Kg (6.4 Lbs
Dimensions (LxWxH)  264 X 104 x 106 (mm)
10.4 X 4.1 X 4.2 (Inches)
Warranty
5 years full warranty on a complete instrument
15 years warranty on the infrared sources
 
Approvals
ATEX / IECEX / INMETRO II 2 G / Ex db eb IIC T6 Gb
CSA C22.2 No 152-M984 and ANSI 12.13.01-2000
Ex d e IIC T6 (for Canada only)
Class I, Division 2, Groups A, B, C and D (USA and Canada
Various SIL 2 certified (software is SIL 3), ABS, MED
Versions
Gas Ranges
Methane 0-100%LEL, 0-100%vo
Propane 0-100%LEL, 0-100%Vol
Other versions are available, please contact your dealer.  
Front cover
Required, select one  
Weather protection Supplied as standard
Sample flow housing For sampling systems and bump test
Duct mount kit For duct monitoring
Accessories
Mosquito net Extra insect protection
Sun shade Shielding for extreme solar radiation exposure or snow deposit
GD10P - ATEX II 2G approved - delivered without cable-gland
  • GD10-P00-17EG-0XH-00 GD10P Detector CH4 Methane 100% LEL (4.4% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2863)
  • GD10-P00-17DG-0BH-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, CSA, 4-20mA, source, HART (Config 2886)
  • GD10-P00-17DG-0BJ-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, CSA, 4-20mA, sink, HART
  • GD10-P00-17DG-0CH-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, UL, 4-20mA, source, HART (Config 2978)
  • GD10-P00-17DG-0CJ-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, UL, 4-20mA, sink, HART
  • GD10-P00-17DG-0XH-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2873)
  • GD10-P00-17DG-0XJ-00 GD10P Detector CH4 Methane 100% LEL (5% Vol.), SS 316L, ATEX, IECEx, 4-20mA, sink, HART (Config 2867)
  • GD10-P00-17BG-0BH-00 GD10P Detector CH4 Methane 100% Vol., SS 316L, CSA, 4-20mA, source, HART (Config 3052)
  • GD10-P00-17BG-0XH-00 GD10P Detector CH4 Methane 100% Vol., SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2849)
  • GD10-P00-18BG-0XH-00 GD10P Detector CH4 Methane 100% Vol. (Biogas), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2855)
  • GD10-P00-18BG-0XJ-00 GD10P Detector CH4 Methane 100% Vol. (Biogas), SS 316L, ATEX, IECEx, 4-20mA, sink, HART
  • GD10-P00-19DG-0XH-00 GD10P Detector CH4O Methanol 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2891)
  • GD10-P00-19DG-0XJ-00 GD10P Detector CH4O Methanol 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, sink, HART (Config 3055)
  • GD10-P00-02DG-0XH-00 GD10P Detector C2H2 Acetylene 100% LEL SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2905)
  • GD10-P00-03DG-0XH-00 GD10P Detector C2H4 Ethylene 100% LEL SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2879)
  • GD10-P00-03DG-0XJ-00 GD10P Detector C2H4 Ethylene 100% LEL SS 316L, ATEX, IECEx, 4-20mA, sink, HART
  • GD10-P00-05EG-0XH-00 GD10P Detector C2H6O Ethanol 100% LEL (3.1% Vol) SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 3021)
  • GD10-P00-05DG-0XH-00 GD10P Detector C2H6O Ethanol 100% LEL (3.5%Vol) SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2930)
  • GD10-P00-07DG-0XH-00 GD10P Detector C3H6 Propene 100% LEL SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2926)
  • GD10-P00-09EG-0XH-00 GD10P Detector C3H8 Propane 100% LEL (1.7% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2997)
  • GD10-P00-09DG-0BH-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, CSA, 4-20mA, source, HART (Config 3015)
  • GD10-P00-09DG-0XH-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2872)
  • GD10-P00-09DG-0XJ-00 GD10P Detector C3H8 Propane 100% LEL (2.2% Vol.), SS 316L, ATEX, IECEx, 4-20mA, sink, HART (Config 2960)
  • GD10-P00-38DG-0BH-00 GD10P Detector n-C4H10 n-Butane 100% LEL, SS 316L, CSA, 4-20mA, source, HART (Config 2989)
  • GD10-P00-38DG-0CH-00 GD10P Detector n-C4H10 n-Butane 100% LEL, SS 316L, UL, 4-20mA, source, HART (Config 3038)
  • GD10-P00-38DG-0XH-00 GD10P Detector n-C4H10 n-Butane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2938)
  • GD10-P00-11DG-0XH-00 GD10P Detector C5H12 Pentane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 3010)
  • GD10-P00-13DG-0XH-00 GD10P Detector C6H6 Benzene 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2943)
  • GD10-P00-73DG-0XH-00 GD10P Detector C6H12 Cyclohexane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2992)
  • GD10-P00-12DG-0XH-00 GD10P Detector C6H14 Hexane 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 2949)
  • GD10-P00-14DG-0XH-00 GD10P Detector C7H8 Toulene 100% LEL (1.2% Vol.), SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 3005)
  • GD10-P00-15DG-0XH-00 GD10P Detector C8H8 Styrene 100% LEL, SS 316L, ATEX, IECEx, 4-20mA, source, HART (Config 3062)
ACCESSORIES FOR GD10P
  • 373-901337 Terminal GD10P/PE/L 4-5
  • 373-903947 Terminal GD10P/PE/L 1-3
  • 499-810913 Splash guard and Weather Protection, GD10P
  • 499-816584 Back cover, kit GD10P/PE/L
  • 540-903951 Ring Sealing (Ø58x3) for Sample flow GD10P
  • 540-903952 Ring Sealing (Ø60x3) for Sample flow GD10PE
  • 540-903954 Ring Sealing (Ø65x2) for Back cover GD10P/PE/L
  • 541-903950 Ex plug stopping M20
  • 599-810646 Test nipple, GD10P
  • 599-811937 Test nipple for GD10P Duct mount
  • 599-904176 Protective Cap for test nipple GD10P/PE
  • 499-810874 Sample flow housing for GD10P. This is also used for testing / Calibration check.
  • 499-811938 Duct mounting kit for GD10P. Mounting flange and front cover.
  • 499-813397 Mosquito net, GD10P, steel mesh
  • 499-815712 Sunshade, GD10P/GD10PE
  • 499-816867 Pipe mounting plate, kit GD10P, M8x2,5" A4 (for 2" pole)
  • 6343489 Cable-gland kit, M20, stainless steel, for armoured cable
  • 6343493 Cable-gland kit, M20, stainless steel, for unarmoured cable
  • 6343495 Cable-gland kit, M20, nickelled brass, for armoured cable
  • 6343499 Cable-gland kit, M20, nickelled brass, for unarmoured cable
Legacy Part Number for SIMRAD GD10P
  • 128-811208.8: Legacy Part Number for SIMRAD GD10P
Write Your Own Review
You're reviewing:Teledyne Oldham Simtronics GD10P Infrared Point Gas Detector
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice