Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Failsafe User-Friendly Interface
  • Environmentally Bulletproof
  • Modular and Serviceable
  • Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty
Delivery options

At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates. 

  • We can ship consignments of all shapes and sizes and hazardous content across the UK and worldwide. Most of our orders are sent via DHL, however sometimes we may use other couriers.
  • If you are purchasing a laboratory product online you can find out the price of shipping checkout. If you are obtaining a quote for a product, then we will email you
    with our best shipping prices along with your quote.
  • Please see our delivery page for full information

Teledyne Detcon DM-700 Toxic Gas Sensor

The Teledyne DM700 Series Sensors are non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display.

The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Failsafe User-Friendly Interface

  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics

Environmentally Bulletproof

  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof,Vibration-Proof

Modular and Serviceable

  • Modular Design
  • Plug and Play Components
  • Quick Thread Release Sensor Endcap (Allen Wrench only required)
  • Integral Calibration Port
Heading Detail
Sensor Type Continuous diffusion/adsorption, 3-electrode electrochemical cell, Plug-in field replaceable Intelligent Type
Outputs Linear 4-20 mA DC, RS-485 MODBUS-RTU
Electrical Classification Explosion proof, CCSAUS, Class I, Division 1, Groups B, C, D, Class I, Zone 1, Group IIC, ATEX, II 2 G Ex d ib IIB + H2 T4 GB
Ingress Protection NEMA 4X, IP66
Safety Approvals cCSAus, ATEX, CE Marking, SIL2 Certified to IEC 61508
Order Guide PN 967 - _ _ _ 090 - _ _ z DM - 700 Sensor Assembly (no junction box), PN 967 - _ _ _ 091 - _ _ z DM - 700 Sensor Assembly with Aluminum J-Box, PN 967 - _ _ _ 094 - _ _ z DM - 700 Sensor Assembly with 316 SS J-Box, _ = Any character as shown in table on prior page, z = Code for Regulatory Approval Required, C for CSA or A for ATEX, others available
Mechanical Specifications Dimensions: 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only), 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box), Mounting holes (J-box) 5.5”; 140mm center to center, Weight: 2 lbs; 0.907kg (sensor only), 6 lbs; 2.72kg (w/aluminum j-box), 9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications Power Input: 11 - 30 VDC,
Power Consumption: Normal operation = 30mA @ 24V (<0.75 watt), Maximum = 50mA @ 24V (1.2 watts),
Inrush Current: 500mA @ 24V (typical),
RFI/EMI Protection: Complies with EN50270,
Analog Output: Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC), 0mA All Fault Diagnostics, 2mA In-Calibration, 4-20mA 0-100% full-scale, 22mA Over-range condition,
Serial RS-485 Output: RS-485 Modbus™ RTU,
Baud Rate: 9600 BPS (9600, N, 8, 1 Half Duplex),
Status Indicators: 4-digit LED display with gas concentration, Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting,
Faults Monitored: Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration,
Cable Requirements: Power/Analog, 3-wire shielded cable, Maximum distance is 13,300 feet with 14 AWG, Serial Output: 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations, Maximum distance is 4,000 feet to last sensor,
I/O Protection: Over-voltage, Miswiring, EMI/RFI Immunity
Model Series 700 Integration Modules in Enclosures
9X7 - XXXXXX - XXX  
Position 13: (xxx-xxxxxx-xxxX)  
700 Series Electro-Chemical H2S Sensor Assemblies
Part Number DESCRIPTION
967-242490-100 DM-700- Electro Chemical H2S Sensor Assembly no condulet
967-242491-100 DM-700- Electro Chemical H2S Gas Sensor Assembly alum. condulet
967-242494-100 DM-700- Electro Chemical H2S Gas Sensor Assembly 316SS condulet
967-333390-010 DM-700-HF Hydrogen Fluoride Sensor Assembly
967-242490-100 DM-700-H2S Hydrogen Sulfide Sensor Assembly
967-12EE90-100 DM-700-CH3OH Methanol Sensor Assembly
967-24EK90-100 DM-700-CH3SH Methyl Mercaptans Sensor Assembly
967-949490-100 DM-700-NO Nitric Oxide Sensor Assembly
967-646490-010 DM-700-NO2 Nitrogen Dioxide Sensor Assembly
967-393990-001 DM-700-O3 Ozone Sensor Assembly
967-192090-005 DM-700-PH3 Phosphine Sensor Assembly
967-555590-020 DM-700-SO2 Sulfur Dioxide Sensor Assembly
Desert Climate (DC) High Temperature sensors (Only available with FM certification)
Part Number DESCRIPTION
967-303090-100M DM-700- Electro Chemical 0-100ppm H2S Sensor (DC) Assembly no condulet
967-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly alum. Condulet
967-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly 316SS condulet
9H7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart bridge Assembly alum. Condulet
9H7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart bridge Assembly 316SS. Condulet
9R7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/RAM Assembly alum. Condulet
9R7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/RAM Assembly 316SS condulet
9K7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart-RAM Assembly alum. Condulet
9K7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart-RAM Assembly 316SS condulet
700 Series Electrochemical Toxic Sensor Assemblies
Part Number DESCRIPTION
967-12EG90-100 DM-700-C2H2 Acetylene Sensor Assembly (Available with Flying leads only!)
967-505090-100 DM-702-NH3 Ammonia Sensor Assembly
967-191990-001 DM-700-AsH3 Arsine Sensor Assembly
967-393990-001 DM-700-O3 Ozone Sensor Assembly
967-192090-005 DM-700-PH3 Phosphine Sensor Assembly
967-555590-020 DM-700-SO2 Sulfur Dioxide Sensor Assembly
9     7 - XXXXX      - XXX  
position 2: (xXx-xxxxxx-xxxx)  
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2            
Part Number DESCRIPTION
975-70000A-00A Remote Control / Alarm Relay Module in Aluminum Enclosure
975-70000A-00S Remote Control / Alarm Relay Module in 316SS Enclosure
975-70000H-00A Remote Control / Alarm Relay Module with Hart in Aluminum Enclosure
975-70000H-00S Remote Control / Alarm Relay Module with Hart in 316SS Enclosure
975-70005H-00A Hart Integration Module in Aluminum Enclosure
975-70005H-00S Hart Integration Module in 316SS Enclosure
Write Your Own Review
You're reviewing:Teledyne Detcon DM-700 Toxic Gas Sensors
Your Rating

Sign up for our latest offers

By submitting your details you consent to their use in accordance with our Privacy Notice