Product Features
  • Failsafe User-Friendly Interface
  • Environmentally Bulletproof
  • Modular and Serviceable
  • Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty
Delivery options

At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.

  • We handle consignments of various sizes across the UK and globally, primarily using DHL, but may select other couriers for specific needs.

  • For online laboratory product purchases, shipping costs are displayed at checkout. For quoted items, shipping prices will be included in your email quote.

  • Please visit our shipping and delivery page for more information here.

Teledyne Detcon DM-700 Toxic Gas Sensor

The Teledyne DM700 Series Sensors are non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display.

The Model 700 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Failsafe User-Friendly Interface

  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics

Environmentally Bulletproof

  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof,Vibration-Proof

Modular and Serviceable

  • Modular Design
  • Plug and Play Components
  • Quick Thread Release Sensor Endcap (Allen Wrench only required)
  • Integral Calibration Port
Heading Detail
Sensor Type Continuous diffusion/adsorption, 3-electrode electrochemical cell, Plug-in field replaceable Intelligent Type
Outputs Linear 4-20 mA DC, RS-485 MODBUS-RTU
Electrical Classification Explosion proof, CCSAUS, Class I, Division 1, Groups B, C, D, Class I, Zone 1, Group IIC, ATEX, II 2 G Ex d ib IIB + H2 T4 GB
Ingress Protection NEMA 4X, IP66
Safety Approvals cCSAus, ATEX, CE Marking, SIL2 Certified to IEC 61508
Order Guide PN 967 - _ _ _ 090 - _ _ z DM - 700 Sensor Assembly (no junction box), PN 967 - _ _ _ 091 - _ _ z DM - 700 Sensor Assembly with Aluminum J-Box, PN 967 - _ _ _ 094 - _ _ z DM - 700 Sensor Assembly with 316 SS J-Box, _ = Any character as shown in table on prior page, z = Code for Regulatory Approval Required, C for CSA or A for ATEX, others available
Mechanical Specifications Dimensions: 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only), 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box), Mounting holes (J-box) 5.5”; 140mm center to center, Weight: 2 lbs; 0.907kg (sensor only), 6 lbs; 2.72kg (w/aluminum j-box), 9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications Power Input: 11 - 30 VDC,
Power Consumption: Normal operation = 30mA @ 24V (<0.75 watt), Maximum = 50mA @ 24V (1.2 watts),
Inrush Current: 500mA @ 24V (typical),
RFI/EMI Protection: Complies with EN50270,
Analog Output: Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC), 0mA All Fault Diagnostics, 2mA In-Calibration, 4-20mA 0-100% full-scale, 22mA Over-range condition,
Serial RS-485 Output: RS-485 Modbus™ RTU,
Baud Rate: 9600 BPS (9600, N, 8, 1 Half Duplex),
Status Indicators: 4-digit LED display with gas concentration, Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting,
Faults Monitored: Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration,
Cable Requirements: Power/Analog, 3-wire shielded cable, Maximum distance is 13,300 feet with 14 AWG, Serial Output: 2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations, Maximum distance is 4,000 feet to last sensor,
I/O Protection: Over-voltage, Miswiring, EMI/RFI Immunity
Model Series 700 Integration Modules in Enclosures
9X7 - XXXXXX - XXX  
Position 13: (xxx-xxxxxx-xxxX)  
700 Series Electro-Chemical H2S Sensor Assemblies
Part Number DESCRIPTION
967-242490-100 DM-700- Electro Chemical H2S Sensor Assembly no condulet
967-242491-100 DM-700- Electro Chemical H2S Gas Sensor Assembly alum. condulet
967-242494-100 DM-700- Electro Chemical H2S Gas Sensor Assembly 316SS condulet
967-333390-010 DM-700-HF Hydrogen Fluoride Sensor Assembly
967-242490-100 DM-700-H2S Hydrogen Sulfide Sensor Assembly
967-12EE90-100 DM-700-CH3OH Methanol Sensor Assembly
967-24EK90-100 DM-700-CH3SH Methyl Mercaptans Sensor Assembly
967-949490-100 DM-700-NO Nitric Oxide Sensor Assembly
967-646490-010 DM-700-NO2 Nitrogen Dioxide Sensor Assembly
967-393990-001 DM-700-O3 Ozone Sensor Assembly
967-192090-005 DM-700-PH3 Phosphine Sensor Assembly
967-555590-020 DM-700-SO2 Sulfur Dioxide Sensor Assembly
Desert Climate (DC) High Temperature sensors (Only available with FM certification)
Part Number DESCRIPTION
967-303090-100M DM-700- Electro Chemical 0-100ppm H2S Sensor (DC) Assembly no condulet
967-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly alum. Condulet
967-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) Assembly 316SS condulet
9H7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart bridge Assembly alum. Condulet
9H7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart bridge Assembly 316SS. Condulet
9R7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/RAM Assembly alum. Condulet
9R7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/RAM Assembly 316SS condulet
9K7-303091-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart-RAM Assembly alum. Condulet
9K7-303094-100M DM-700- Electro Chemical 0-100ppm H2S Gas Sensor (DC) w/Hart-RAM Assembly 316SS condulet
700 Series Electrochemical Toxic Sensor Assemblies
Part Number DESCRIPTION
967-12EG90-100 DM-700-C2H2 Acetylene Sensor Assembly (Available with Flying leads only!)
967-505090-100 DM-702-NH3 Ammonia Sensor Assembly
967-191990-001 DM-700-AsH3 Arsine Sensor Assembly
967-393990-001 DM-700-O3 Ozone Sensor Assembly
967-192090-005 DM-700-PH3 Phosphine Sensor Assembly
967-555590-020 DM-700-SO2 Sulfur Dioxide Sensor Assembly
9     7 - XXXXX      - XXX  
position 2: (xXx-xxxxxx-xxxx)  
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2            
Part Number DESCRIPTION
975-70000A-00A Remote Control / Alarm Relay Module in Aluminum Enclosure
975-70000A-00S Remote Control / Alarm Relay Module in 316SS Enclosure
975-70000H-00A Remote Control / Alarm Relay Module with Hart in Aluminum Enclosure
975-70000H-00S Remote Control / Alarm Relay Module with Hart in 316SS Enclosure
975-70005H-00A Hart Integration Module in Aluminum Enclosure
975-70005H-00S Hart Integration Module in 316SS Enclosure
Write Your Own Review
You're reviewing:Teledyne Detcon DM-700 Toxic Gas Sensors
Your Rating