Please email / call for availability
Get a quote
Enter your details and we will get back to you as soon as possible.

Product Features
  • Multi-combustible gas detection
  • Range of 200 meters
  • Low maintenance costs
  • Easy detector communication
  • Easy configuration and troubleshooting
  • Automatic heated optics
  • Built-in event recorder
  • Stainless steel construction
Delivery options

At Cadmus Products we aim to deliver orders efficiently and at highly competitive rates. 

  • We can ship consignments of all shapes and sizes and hazardous content across the UK and worldwide. Most of our orders are sent via DHL, however sometimes we may use other couriers.
  • If you are purchasing a laboratory product online you can find out the price of shipping checkout. If you are obtaining a quote for a product, then we will email you
    with our best shipping prices along with your quote.
  • Please see our delivery page for full information

Teledyne Oldham Spyglass

The Teledyne Spyglass Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.

Spyglass Key Features:

  • Multi-combustible gas detection
  • Range of 200 meters
  • Low maintenance costs
  • Easy detector communication
  • Easy configuration and troubleshooting
  • Automatic heated optics
  • Built-in event recorder
  • Stainless steel construction
  • Save costs in line-of-sight applications

One Spyglass Open Path Detector can replace up to 20 point combustible gas detectors in line-of-sight applications, saving installation and ongoing maintenance costs. With the Spyglass there are only two units to service and the maintenance requirements are minimized compared with point detectors. Additionally, there is only one consumable to replace periodically; 
Detect multiple combustible gases simultaneously

The Spyglass IR sensor can detect multiple combustible hydrocarbon gases at the same time—perfect for facilities with multiple hydrocarbon gases to monitor, such as C1-C8 hydrocarbons (Methane, Ethane, Ethylene, Propane, Propylene, n-butane, Isobutane, 1, 3-butadiene, Isobutylene, Alkanes, Alkenes, Naphthenes, Benzenes). 
Handle tough environments with confidence, longer

Robustly designed to handle the toughest work environments and maintain a long operating life, the Spyglass Open Path Gas Detector is equipped with 316L stainless steel casings and mounts, coated circuit boards for protection, and is SIL-2 approved per IEC61508. Additionally, the Spyglass detector meets MIL-C-810C standards for humidity, salt, fog, vibration, mechanical shock and temperature extremes, while the housings meet IP66, IP68 and NEMA 250 6P water and dust egress standards.

SKU

Description

SPYGLASS (with tilt mount, without cable gland) ATEX 2 GD (Ex de(ia) IIC T5)

  • SCO-8000481 Spyglass Model 20, distance 7 to 20 m, ATEX, M25, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000482 Spyglass Model 20, distance 7 to 20 m, ATEX, ¾ NPT, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000485 Spyglass Model 40, distance 15 to 40 m, ATEX, M25, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000486 Spyglass Model 40, distance 15 to 40 m, ATEX, ¾ NPT, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000489 Spyglass Model 100, distance 35 to 100 m, ATEX, M25, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000490 Spyglass Model 100, distance 35 to 100 m, ATEX, ¾ NPT, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000493 Spyglass Model 200, distance 80 to 200 m, ATEX, M25, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

  • SCO-8000494 Spyglass Model 200, distance 80 to 200 m, ATEX, ¾ NPT, 4-20mA output, RS485 and HART, SIL 2, c/w tilt mount

ACCESSORIES FOR Spyglass

  • SCO-8000447 Tilt Mount (Stainless steel)

  • SCO-8000448 Pole Mount (U-Bolt 5 inch)

  • SCO-8000449 Commissioning Kit

  • SCO-8000451 HART Hand-Held Diagnostic Unit

  • SCO-8000452 HART Hand-Held Harness Kit

  • SCO-8000453 USB/RS485 Harness Converter Kit

  • SCO-8000455 Sunshade, Stainless Steel

  • SCO-8000457 Function Check Filter Warning Level - Methane Calibration

  • SCO-8000458 Function Check Filter Alarm Level - Methane Calibration

  • SCO-8000459 Function Check Filter Warning Level - Propane Calibration

  • SCO-8000460 Function Check Filter Alarm Level - Propane Calibration

  • SCO-8000497 Magnetic Mode Selector

    Spyglass Spares

    • SCO-8000461 Spyglass Detector , ATEX, M25

    • SCO-8000462 Spyglass Detector , ATEX, 3/4" NPT

    • SCO-8000463 Spyglass Detector , FM, M25

    • SCO-8000464 Spyglass Detector , FM, 3/4" NPT

    • SCO-8000465 Spyglass Model 20 Source (7-20 m Range), ATEX, M25

    • SCO-8000466 Spyglass Model 20 Source (7-20 m Range), ATEX, 3/4" NPT

    • SCO-8000467 Spyglass Model 20 Source (7-20 m Range), FM, M25

    • SCO-8000468 Spyglass Model 20 Source (7-20 m Range), FM, 3/4" NPT

    • SCO-8000469 Spyglass Model 40 Source (15-40 m Range), ATEX, M25

    • SCO-8000470 Spyglass Model 40 Source (15-40 m Range), ATEX, 3/4" NPT

    • SCO-8000471 Spyglass Model 40 Source (15-40 m Range), FM, M25

    • SCO-8000472 Spyglass Model 40 Source (15-40 m Range), FM, 3/4" NPT

    • SCO-8000473 Spyglass Model 100 Source (35-100 m Range), ATEX, M25

    • SCO-8000474 Spyglass Model 100 Source (35-100 m Range), ATEX, 3/4" NPT

    • SCO-8000475 Spyglass Model 100 Source (35-100 m Range), FM, M25

    • SCO-8000476 Spyglass Model 100 Source (35-100 m Range), FM, 3/4" NPT

    • SCO-8000477 Spyglass Model 200 Source (80-200 m Range), ATEX, M25

    • SCO-8000478 Spyglass Model 200 Source (80-200 m Range), ATEX, 3/4" NPT

    • SCO-8000479 Spyglass Model 200 Source (80-200 m Range), FM, M25

    • SCO-8000480 Spyglass Model 200 Source (80-200 m Range), FM, 3/4"NPT

    Write Your Own Review
    You're reviewing:Teledyne Oldham Spyglass
    Your Rating

    Sign up for our latest offers

    By submitting your details you consent to their use in accordance with our Privacy Notice