Displays up to three measurements simultaneously
Measures humidity (Model 9545 and 9545-A)
Calculates volumetric flow and actual/standard velocity
Data log 12,700+ samples and 100 test IDs
LogDat2TM downloading software included
Articulated probe versions available (9535-A and 9545-A)
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
The TSI 9545 VelociCalc Air Velocity Meter simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors.
It measure velocity, temperature and calculate flow. The Model 9545 also measures relative humidity, and calculates dew point, and wet bulb temperature.
The product has telescopic straight probes.
Displays up to three measurements simultaneously
Measures humidity (Model 9545 and 9545-A)
Calculates volumetric flow and actual/standard velocity
Data log 12,700+ samples and 100 test IDs
LogDat2TM downloading software included
Articulated probe versions available (9535-A and 9545-A)
Velocity | |
Range | 0 to 6,000 ft/min (0 to 30 m/s) |
Accuracy | ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater |
Resolution | 1 ft/min (0.01 m/s) |
Duct Size | |
Dimensions | 1 to 250 inches in increments of 0.1 in. (1 to 635 cm in increments of 0.1 cm) |
Volumetric Flow Rate | |
Range | Actual range is a function of velocity and duct size |
Temperature | |
Range | 14 to 140°F (-10 to 60°C) |
Accuracy | ±0.5°F (±0.3°C) |
Resolution | 0.1°F (0.1°C) |
Relative Humidity | |
Range | 5 to 95% RH |
Accuracy | ±3% RH |
Range | 0.1% RH |
Instrument Temperature Range | |
Operating (Electronics) | 40 to 113°F (5 to 45°C) |
Model 9545 Operating (Probe) | 14 to 140°F (-10 to 60°C) |
Storage | -4 to 140°F (-20 to 60°C) |
Data Storage Capabilities | |
Range | 12,700+ samples and 100 test IDs |
Logging Interval | |
1 second to 1 hour | |
Time Constant | |
User selectable | |
External Meter Dimensions | |
3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm) | |
Meter Weight with Batteries | |
0.6 lbs. (0.27 kg) | |
Meter Probe Dimensions | |
Probe Length | 40 in. (101.6 cm) |
Probe Diameter of Tip | 0.28 in. (7.0 mm) |
Probe Diameter of Base | 0.51 in. (13.0 mm) |
Articulating Probe Dimensions | |
Articulating Section Length | 7.8 in. (19.7 cm) |
Diameter of Articulating Knuckle | 0.38 in. (9.5 mm) |
Power Requirements | |
Four AA-size batteries or AC adapter |
Models |
|
Accessories and Replacement Parts |
|
By submitting your details you consent to their use in accordance with our Privacy Notice