Positive and Negative Duct Leakage Testing in one rig
Energy savings by testing and minimizing duct leaks
Accuracy is ± 2,5% of volume flow
At Cadmus Products, we prioritise efficient order delivery and offer competitive shipping rates worldwide. Our streamlined process ensures clarity and reliability for all your shipping requirements.
The TSI Airflow™ Instruments Positive and Negative Duct Accreditation (PANDA) System PAN341 Series provides contractors, commissioning engineers, and research and development technicians with the best in class choice of test equipment to quantify air leakage in ductwork and other areas as well as the ability to measure the performance of ducted systems.
The PANDA provides a fast, accurate, automated solution and helps to ensure compliance with European standards like EN12237, EN1507, EN13779, EUROVENT 2/2 standards and with American standards like SMACNA, enhancing energy savings in buildings.
Positive and Negative Duct Leakage Testing in one rig
Energy savings by testing and minimizing duct leaks
Compliant with the following standards:
EN13779 Ventilation for Buildings—Achieve a good air quality with acceptable installation and running costs
EN12237 Ventilation for Buildings—Ductwork strength and leakage of circular sheet metal ducts
EN12237 Ventilation for Buildings—Test procedures with measuring methods
HVCA DW/143 Ventilation for Buildings—Guidance document for ductwork leakage testing
EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution Systems
SMACNA Sheet Metal And Air Conditioning Contractors National Association
Accuracy is ± 2,5% of volume flow
Unique performance and fan speed control charge up of duct system to test static pressure within minutes
Fits in the back of vans and estate cars
Model PAN341 comes with standard Airflow TA465-P Multi-Function Instrument and PVM610 Micromanometer.
Automatically calculates leakage rate in real time
Simultaneous displays flow leakage rate and static pressure
Provides a pass/fail indication for a given tightness class
Automatically corrects actual volume flow leakage rate to Standard Temperature and Pressure (STP)
Monitors barometric pressure and temperature in real time
Stores data that can be downloaded for report generation and documentation
Works with Model 8934 Portable Printer
Carry weight of 45 kg (99 lbs)
Power requirements | 110 to 120 V, 1 Phase, 50/60 Hz, 16A |
Carry Weight | 45 kg (99 lbs.) |
Total Weight | 55 kg (121 lbs.) |
Dimensions (L x W x H) | 1,130 mm x 660 mm x 600 mm (44.5 in. x 26 in. x 23.5 in.) |
Pressure Measurement (PVM610) | Range ± 3,735 Pa (± 15 in. W.G.) Resolution 0.1 Pa (0.001 in. W.G.) Accuracy 1% of reading ± 1 Pa (± 0.005 in. W.G.) Actual Duct Static Range ± 2,500 Pa (± 10 in. W.G.) at Zero Flow |
Volume Flow Measurement (TA465-P) |
Wilson Radial Flow Grid High leakage range: 10 to 200 l/s (36 to 720 m3/hr, 21 to 424 cfm) 15 mm Conical Inlet Nozzle Adapter Low leakage range: 1 to 13 l/s (3.6 to 46.9 m3/hr, 2 to 27.5 cfm) Resolution 0.01 l/s (0.01 m3/hr, 0.01 cfm) Accuracy ± 2.5% of reading ± 0.01 l/s (± 0.04 m3/hr, ± 0.02 cfm) |
Temperature Measurement (TA465-P) |
K Type thermocouple probe To EN60584 (IEC 584) |
Barometric Pressure Measurement (TA465-P) |
Range 690 to 1,241 hPa (517.5 to 930.87 mm Hg, 20.36 to 36.648 in. Hg) Accuracy ± 2% of reading |
Model |
Description |
---|---|
PAN341 |
Duct leakage tester with instruments, 230v. Includes TA465-P and PVM610 Micromanometer |
PAN341-NB |
Duct leakage tester with instruments, 230v. Includes TA465-P-NB and PVM610 Micromanometer |
PAN341-110 |
Duct leakage tester with instruments, 110v. Includes TA465-P and PVM610 Micromanometer |
PAN341-110-NB |
Duct leakage tester with instruments, 110v. Includes TA465-P-NB and PVM610 Micromanometer |
Accessories and Replacement Parts |
|
By submitting your details you consent to their use in accordance with our Privacy Notice