Designed for when resilience matters most, the Crowcon Vortex FP Gas Detection Control Panel and Vortex FP Compact are ATEX-certified Exd Flameproof gas detector control panels, ideal for use in hazardous areas such as on offshore production platforms or refineries. Alongside all of the standard Vortex features, Vortex FPs come with a display that allows interrogation without opening the system enclosure, for enhanced durability.
Simple to Use:
Highly Flexible:
Robust and Reliable:
|
VORTEX
|
VORTEX RACK/PANEL
|
SIZE
|
440 x 640 x 332mm (17.3 x 25 x 13 ins)
|
450 x 330 x 289mm (17.6 x 13 x 11.4 ins)
|
WEIGHT
|
70Kgs (154lbs) approx.
|
37.5kgs (83lbs) approx.
|
ENCLOSURE MATERIAL
|
LM25 aluminium with polyester powder coating
|
|
INGRESS PROTECTION
|
IP66
|
|
CHANNELS
|
Up to 12 (1 to 3 4-way input modules)
|
|
OPERATING TEMPERATURE
|
-10°C to +40°C (14°F to +140°F)
|
|
HUMIDITY
|
0-95% RH non-condensing
|
|
INPUTS
|
Gas 2 or 3 wire 4-20mA (sink or source), 0-5V
|
|
-Fire – smoke & heat detectors, manual call-points Up to 3 loops, Up to 20 devices per loop
|
||
OUTPUTS
|
External audible/visual alarm drive Via relays, four 24Vdc 0.5A supplies provided.
|
|
RELAYS
|
Type Up to 32 SPCO with bus extension module
|
Relay limitations: 1 or 2 input modules: 2 relay modules max. (16 relays) 3 input modules: 1 relay module only (8 relays)
|
Assignment – Common Battery back-up not available
|
||
Assignment – Voting Alarms, faults and system events
|
||
Relay modes Energised/de-energised, latched/non-latched, time-delayed, pulsed
|
||
DIGITAL COMMUNICATIONS
|
DCS/PLC/PC: RS-485 Modbus or Profibus
Local configuration link: RS-232 (configuration software and lead supplied)
|
|
EVENT LOGGING
|
Up to 300 alarm, power, fault, and system events are stored in Non-Volatile Memory
|
|
PANEL INDICATION
|
Channel number: 2-digit 7-segment Green LED
Gas reading: 4-digit 7-segment Red LED
Measurement units: % LEL, ppm, % Vol, Fire
Power: Green LED
Battery OK: Green LED
Run/hold indication: Green LED
Channel test mode: Flashing Amber LED
System fault – integrity watchdog: Amber LED
Displayed information can be altered and outputs can be inhibited during calibration using a magnetic key
|
|
ALARM INDICATION
|
Audible – internal sounder: Piezo
Visual – Alarm: Level 1 & 2, Red LED; Fault – Per channel, Amber LED; Inhibit – Per zone, Amber LED
|
|
POWER
|
AC mains/DC: 110 or 240Vac 3.2A max 150W PSU 20 – 30Vdc
|
|
Battery backup: not available
|
||
APPROVALS
|
Low voltage directive: EN61010-1
EMC: Directive 2014/30/EU: EN50270, FCC: CRF47 Part 15, ICES-003
ATEX: Ex II 2G D Zone 1, Zone 2, IECEx optional
|
|
FUNCTIONAL SAFETY
|
Validated to IEC61508
|