The Horiba LAQUA 1500 Series comprises benchtop meters designed for routine applications and educational purposes, emphasizing simplicity and affordability. These meters offer essential functionalities without unnecessary complexities, making them suitable for both laboratory and training environments.
|
|
Model |
LAQUA PH1500 pH/ORP/Temperature (°C) |
---|---|
pH Range |
-2.00 to 16.00 pH |
Resolution |
0.1 / 0.01 pH |
Accuracy |
± 0.01 pH |
Calibration Points |
Up to 5 |
Buffer Options |
USA / NIST |
ORP Range |
± 2000 mV |
Resolution |
0.1 mV |
Accuracy |
± 0.2 mV |
Temperature Range |
-30.0 to 130.0 °C |
Resolution |
0.1 °C |
Accuracy |
± 0.5 °C |
Calibration Option |
Yes |
Memory Data |
1000 |
Auto-Hold / Auto-Stable |
Yes |
Offset / Slope Display |
Yes (Independent acid and alkaline slopes depending on calibration) |
Electrode Status |
On screen display |
Diagnostic Messages |
Yes |
Display |
Custom black and white static LCD |
Inputs |
BNC, phono, DC sockets |
Output |
USB/RS232C |
Power Requirement |
AC adaptor, 100-240V, 50/60Hz |
Weight |
Meter : 727g |
Dimensions |
Meter : 155(L) x 150(D) x 67(H) mm |
LAQUA-EC1500 Conductivity/Resistivity/TDS/Salinity/Temp (°C/°F) Bench Meter |
|
Conductivity Range | 0.00 μS - 200.0 mS |
Resolution | 0.01 / 0.1 / 1 µS ; 0.01 / 0.1 mS |
Accuracy | ±0.6% full scale, ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15.0 to 30.0 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00 % per °C (adjustable) |
Cell Constants | 0.070 to 13.00 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Units | S/cm, S/m (Auto ranging) |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.5% full scale |
Accuracy | ±0.6% full scale, ±1.5% full scale > 1.80 MΩ•cm |
Total Dissolved Solids (TDS) Range | 0 ppm - 100 ppt |
Resolution | 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt |
Accuracy | ±0.1% full scale |
TDS Curves | EN27888, 442, NaCl, Linear (0.40 to 1.00) |
Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01% |
Accuracy | ±0.2% full scale |
Salinity Curves | NaCl / Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes ( ± 10.0 °C / ± 18.0 °F range in 0.1 °C increments) |
Memory | 1000 data sets |
Auto Data Log | Yes |
Measurement Modes | Auto Stable / Auto Hold / Real Time |
Auto Shut-Off | Yes (programmable: 1 to 30 mins.) |
Electrode Status | On screen display |
PC / Printer Communication | Phono jack (USB / RS232) |
Meter Inputs | BNC, phono (ATC), DC sockets |
Display | Static segment LCD with 160 segments |
Power Requirement | AC adaptor 100 - 240V, 50 - 60Hz |
Dimensions | 155 (L) x 150 (W) x 67 (H) mm |
Weight | Approx. 730g |
Electrode Stand | Integrated |
LAQUA-PC1500 pH/ORP/Conductivity/Resistivity/TDS/Salinity/Temp (°C/°F) Bench Meter |
|
pH Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ± 0.01 pH |
pH Buffer Groups | USA, NIST, DIN |
Calibration Points | Up to 5 (USA, NIST) / Up to 6 (DIN) |
ORP Range | ± 2000.0 mV |
Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000mV) |
Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000mV) |
Calibration Option | Yes (Up to ±200 mV) |
Conductivity Range | 0.00 μS – 200.0 mS |
Resolution | 0.01 / 0.1 / 1 µS ; 0.01 / 0.1 mS |
Accuracy | ±0.6% full scale, ±1.5% full scale > 18.0 mS/cm |
Reference Temperature | 15.0 to 30.0 °C (adjustable) |
Temperature Coefficient | 0.00 to 10.00 % per °C (adjustable) |
Cell Constants | 0.070 to 13.00 (adjustable) |
Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
Units | S/cm, S/m (Auto ranging) |
Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
Resolution | 0.5% full scale |
Accuracy | ±0.6% full scale, ±1.5% full scale > 1.80 MΩ•cm |
Total Dissolved Solids (TDS) Range | 0 ppm – 100 ppt |
Resolution | 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt |
Accuracy | ±0.1% full scale |
TDS Curves | EN27888, 442, NaCl, Linear (0.40 to 1.00) |
Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
Resolution | 0.1 ppt / 0.01% |
Accuracy | ±0.2% full scale |
Salinity Curves | NaCl / Seawater |
Calibration Option | Yes |
Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
Resolution | 0.1 °C / °F |
Accuracy | ± 0.5 °C / ± 0.9 °F |
Calibration Option | Yes ( ± 10.0 °C / ± 18.0 °F range in 0.1 °C increments) |
Memory | 1000 data sets |
Auto Data Log | Yes |
Measurement Modes | Auto Stable / Auto Hold / Real Time |
Offset & Slope Display | Yes (Average slope) |
Auto Shut-Off | Yes (programmable: 1 to 30 mins.) |
Electrode Status | On screen display |
PC / Printer Communication | Phono jack (USB / RS232) |
Meter Inputs | 2 x BNC, 2 x phono (ATC), DC sockets |
Display | Static segment LCD with 160 segments |
Power Requirement | AC adaptor 100 - 240V, 50 - 60Hz |
Dimensions | 155 (L) x 150 (W) x 67 (H) mm |
Weight | Approx. 740g |
Electrode Stand | Integrated |